Skip to main content
WireAndSun
Calculators
CEC PV Module

REC Group REC275TP2 BLK — CEC Solar Module Specifications

Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC275TP2 BLK is a 275.0 W STC (253.7 W PTC) Multi-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.98% efficiency, 38.2 V Voc at 25 C, and 42.05 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
275.0 W
PTC Wattage
253.7 W
Voc @ 25C
38.2 V
Efficiency
16.98%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC275TP2 BLK Compare Against Peer CEC Listings?

How REC Group REC Group REC275TP2 BLK handles rooftop heat (253.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, REC Group REC275TP2 BLK exhibits 9.52 A short-circuit current, requiring a 14.85 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #18,259 of 21,677 (3.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 48.6 m2 for an 8 kW system (37 panels for 10 kW). Lower 38.2 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does REC Group REC275TP2 BLK Fall Across Listed CEC Models?

Where REC Group REC275TP2 BLK (275.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC275TP2 BLK (275.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC275TP: 275.0 W

What Dataset Percentiles Define REC Group REC275TP2 BLK?

Percentile placement of REC Group REC275TP2 BLK across power density (169.8 W/m2), thermal retention, and nameplate STC wattage.

REC Group REC275TP2 BLK Engineering BenchmarksPercentile comparison of REC Group REC275TP2 BLK wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage275.0 WPTC/STC Retention92.3%Module Efficiency16.98%

What Do the Dataset Ranks Show for REC Group REC275TP2 BLK?

Four critical engineering numbers homeowners and solar installers check first when reviewing REC Group REC275TP2 BLK specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #18,259 / 21,677

275.0 W STC · Higher Than 14.3%

275.0 W STC (-110.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,550

16.98% Aperture Efficiency

Power density 169.8 W/m2 (2.93 percentage points below 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.05 V at -10 C (588.7 V string) and 43.15 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,250 W STC

Occupies 48.6 m2 (523 sq ft) producing 7,611 W PTC; NEC 690.8 OCPD floor is 14.85 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.2 * (1 + (-0.288/100) * (-10 - 25)) = 42.05 V | OCPD = 1.56 * 9.52 = 14.85 A

Inputs from CEC Modules.csv for REC Group REC275TP2 BLK: Voc=38.2 V, beta_Voc=-0.288%/C, Isc=9.52 A, STC=275.0 W, Area=1.62 m2.

Result: 14 panels max on 600 V (588.7 V); 30 panels for 8 kW (523 sq ft).

What Are the Published CEC Specifications for REC Group REC275TP2 BLK?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for REC Group REC275TP2 BLK.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC275TP2 BLK.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 275.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 253.7 W (92.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.52 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.5 V / 8.74 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.288 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.98% (1.62 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many REC Group REC275TP2 BLK Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using REC Group REC275TP2 BLK (275.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.05 kW 384 sq ft $1,514 $2,561
8 kW Class 30 8.25 kW 523 sq ft $2,065 $3,492
10 kW Class 37 10.18 kW 645 sq ft $2,548 $4,308

Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

All closely matched REC Group wattages and cosmetic trims sharing the REC Group REC275TP2 BLK architecture. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the REC Group REC275TP2 BLK wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
REC Group REC275TP2 BLK 275.0 W 253.7 W 38.2 V 31.5 V 16.98%
REC Group REC280TP2 280.0 W 258.4 W 38.4 V 31.7 V 17.28%
REC Group REC280TP2 BLK 280.0 W 258.4 W 38.4 V 31.7 V 17.28%
REC Group REC285TP2 285.0 W 263.2 W 38.6 V 31.9 V 17.59%
REC Group REC285TP2 BLK 285.0 W 263.2 W 38.6 V 31.9 V 17.59%
REC Group REC290TP2 290.0 W 267.9 W 38.8 V 32.1 V 17.9%
REC Group REC290TP2 BLK 290.0 W 267.9 W 38.8 V 32.1 V 17.9%
REC Group REC295TP2 295.0 W 272.7 W 39.0 V 32.3 V 18.21%
REC Group REC295TP2 BLK 295.0 W 272.7 W 39.0 V 32.3 V 18.21%

How Many REC Group REC275TP2 BLK Modules Fit in a Cold-Weather String?

Maximum series module counts for REC Group REC275TP2 BLK from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.2V and beta_Voc=-0.288%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.15 V 13 panels 560.9 V 23 panels
-10 C (14 F) 42.05 V 14 panels 588.7 V 23 panels
0 C (32 F) 40.95 V 14 panels 573.3 V 24 panels
25 C (77 F STC) 38.2 V 15 panels 573.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC275TP2 BLK?

Alternative CEC solar modules from competing brands near REC Group REC275TP2 BLK (275.0 W), including Anhui Rinengzhongtian Semiconductor Development QJP275-60.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Anhui Rinengzhongtian Semiconductor Development QJP275-60
Anhui Rinengzhongtian Semiconductor Development
275.0 W Tie (0 W) 38.01 V 16.9% 90.8%
Chinaland Solar Energy HSE275-60M-B
Chinaland Solar Energy
275.0 W Tie (0 W) 38.0 V 16.09% 90.5%
CSI Solar Co Ltd CS6P-275P
CSI Solar Co Ltd
275.0 W Tie (0 W) 38.0 V 17.26% 91.6%
AXITEC AC-275P/60S
AXITEC
275.0 W Tie (0 W) 38.5 V 16.87% 92.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC275TP2 BLK?

Evaluate REC Group REC275TP2 BLK (275.0 W STC, 38.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC275TP2 BLK reaches 43.15 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 523 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (523 sq ft).
  • 2026 tax credit baseline: cash residential installs of REC Group REC275TP2 BLK carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC275TP2 BLK 8 kW Residential Fit

Needs 30 modules (523 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJP275-60.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 253.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC275TP2 BLK by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

Why is REC Group REC275TP2 BLK PTC wattage (253.7 W) lower than STC (275.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 253.7 W PTC (92.3% retention) across REC Group REC275TP2 BLK's 1.62 m2 aperture.

Who should skip REC Group REC275TP2 BLK on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 30 REC Group REC275TP2 BLK panels (523 sq ft) leave unusable roof gaps vs. Anhui Rinengzhongtian Semiconductor Development QJP275-60.

What is the 1,000 V commercial string limit for REC Group REC275TP2 BLK?

On 1,000 V commercial inverters at -10 C (42.05 V cold Voc), REC Group REC275TP2 BLK fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting REC Group REC275TP2 BLK.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.