Qcells North America QPEAK DUO L-G52 385 is a 385.0 W STC (356.8 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.74% efficiency, 48.21 V Voc at 25 C, and 52.8 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 385.0 W
- PTC Wattage
- 356.8 W
- Voc @ 25C
- 48.21 V
- Efficiency
- 19.74%
How Does Qcells North America QPEAK DUO L-G52 385 Compare Against Peer CEC Listings?
Engineering position of Qcells North America QPEAK DUO L-G52 385 (385.0 W STC) vs. AXITEC AC-385MH/144S across 5,889 CEC Mono-c-Si solar modules.
Ranking #10,723 across 21,677 CEC solar panels (at all-CEC median; higher than 49.1% of peers), Qcells North America QPEAK DUO L-G52 385 operates as a compact residential or specialty off-grid module sitting 25.0 W below the 410.0 W Mono-c-Si median. Higher 48.21 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677), 21 panels occupy 441 sq ft and offset roughly $2,025/yr at average US rates (or $3,424/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Qcells North America QPEAK DUO L-G52 385 Fall Across Listed CEC Models?
Plots Qcells North America QPEAK DUO L-G52 385 at 385.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Qcells North America QPEAK DUO L-G52 385?
Benchmarks Qcells North America QPEAK DUO L-G52 385 on STC wattage, thermal PTC/STC retention, and 19.74 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Qcells North America QPEAK DUO L-G52 385?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Qcells North America QPEAK DUO L-G52 385 by Qcells North America.
385.0 W STC · Higher Than 49.1%
385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.
19.74% Aperture Efficiency
Power density 197.4 W/m2 (0.17 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.8 V at -10 C (580.8 V string) and 54.11 V at -20 C (11 max).
21 Panels = 8,085 W STC
Occupies 40.9 m2 (441 sq ft) producing 7,493 W PTC; NEC 690.8 OCPD floor is 15.76 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.21 * (1 + (-0.272/100) * (-10 - 25)) = 52.8 V | OCPD = 1.56 * 10.1 = 15.76 A
Inputs from CEC Modules.csv for Qcells North America QPEAK DUO L-G52 385: Voc=48.21 V, beta_Voc=-0.272%/C, Isc=10.1 A, STC=385.0 W, Area=1.95 m2.
Result: 11 panels max on 600 V (580.8 V); 21 panels for 8 kW (441 sq ft).
What Are the Published CEC Specifications for Qcells North America QPEAK DUO L-G52 385?
Laboratory test ratings recorded for Qcells North America QPEAK DUO L-G52 385 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 385.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 356.8 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.21 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.1 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.05 V / 9.61 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.272 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.74% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 144 cells (Mono-c-Si) | Monofacial backsheet |
How Many Qcells North America QPEAK DUO L-G52 385 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (441 sq ft at 8 kW), and estimated Year-1 electric bill offset for Qcells North America QPEAK DUO L-G52 385.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.16 kW | 336 sq ft | $1,542 | $2,607 |
| 8 kW Class | 21 | 8.09 kW | 441 sq ft | $2,025 | $3,424 |
| 10 kW Class | 26 | 10.01 kW | 546 sq ft | $2,505 | $4,236 |
How Many Qcells North America QPEAK DUO L-G52 385 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Qcells North America QPEAK DUO L-G52 385 (beta_Voc -0.272%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.11 V | 11 panels | 595.2 V | 18 panels |
| -10 C (14 F) | 52.8 V | 11 panels | 580.8 V | 18 panels |
| 0 C (32 F) | 51.49 V | 11 panels | 566.4 V | 19 panels |
| 25 C (77 F STC) | 48.21 V | 12 panels | 578.5 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Qcells North America QPEAK DUO L-G52 385?
Closest cross-brand CEC competitors to Qcells North America QPEAK DUO L-G52 385 matched near 385.0 W STC and 48.21 V Voc, led by AXITEC AC-385MH/144S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-385MH/144S AXITEC |
385.0 W | Tie (0 W) | 48.0 V | 19.41% | 92.9% |
| AXITEC AC-385MH/144V AXITEC |
385.0 W | Tie (0 W) | 48.0 V | 19.41% | 92.9% |
| CSI Solar Co Ltd CS3U-385P CSI Solar Co Ltd |
385.0 W | Tie (0 W) | 48.0 V | 20.05% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-385L-H Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.45 V | 19.35% | 93.2% |
What Are the Design Limits and Best-Fit Uses for Qcells North America QPEAK DUO L-G52 385?
Evaluate Qcells North America QPEAK DUO L-G52 385 (385.0 W STC, 48.21 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Qcells North America QPEAK DUO L-G52 385 reaches 54.11 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (441 sq ft).
- 2026 tax credit baseline: cash residential installs of Qcells North America QPEAK DUO L-G52 385 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Qcells North America QPEAK DUO L-G52 385 8 kW Residential Fit
Needs 21 modules (441 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-385MH/144S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 356.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Qcells North America QPEAK DUO L-G52 385 by Qcells North America grounded in CEC test data and NEC 690.7/690.8 limits.
How many Qcells North America QPEAK DUO L-G52 385 panels fit on a 600 V winter solar string?
At -10 C (14 F), Qcells North America QPEAK DUO L-G52 385 cold Voc rises from 48.21 V to 52.8 V (beta_Voc -0.272%/C), capping a 600 V string at 11 panels (580.8 V).
How much roof area does an 8 kW array of Qcells North America QPEAK DUO L-G52 385 need?
An 8 kW DC system uses 21 Qcells North America QPEAK DUO L-G52 385 modules (8,085 W STC / 7,493 W PTC), covering roughly 441 sq ft and saving ~$2,025/yr at 18.54 c/kWh.
How does Qcells North America QPEAK DUO L-G52 385 compare against AXITEC AC-385MH/144S?
Qcells North America QPEAK DUO L-G52 385 outputs 385.0 W STC (48.21 V Voc, rank #10,723 of 21,677), while AXITEC AC-385MH/144S delivers 385.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)