Skip to main content
WireAndSun
Calculators
CEC PV Module

PT SURYA PERTAMA INDONESIA LP-585-144MT-W — CEC Solar Module Specifications

Manufacturer: PT SURYA PERTAMA INDONESIA Registry: CEC Verified Engineering Specification

PT SURYA PERTAMA INDONESIA LP-585-144MT-W is a 585.0 W STC (556.4 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.67% efficiency, 53.43 V Voc at 25 C, and 58.24 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
585.0 W
PTC Wattage
556.4 W
Voc @ 25C
53.43 V
Efficiency
22.67%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PT SURYA PERTAMA INDONESIA LP-585-144MT-W Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PT SURYA PERTAMA INDONESIA LP-585-144MT-W (Mono-c-Si) residential solar systems.

PT SURYA PERTAMA INDONESIA LP-585-144MT-W delivers 226.7 W/m2 (2.76 percentage points above 19.91% CEC median) and strong 95.1% PTC-to-STC heat retention (#713 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 59.61 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with FreeVolt ECP-PVGRAF-HC-BF585-144MT-B (585.0 W).

Where Does PT SURYA PERTAMA INDONESIA LP-585-144MT-W Fall Across Listed CEC Models?

Comparison of PT SURYA PERTAMA INDONESIA LP-585-144MT-W (585.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PT SURYA PERTAMA INDONESIA LP-585-144MT-W (585.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPT SURYA PERTAMA I: 585.0 W

What Dataset Percentiles Define PT SURYA PERTAMA INDONESIA LP-585-144MT-W?

Relative ranking of PT SURYA PERTAMA INDONESIA LP-585-144MT-W across nameplate watts, 95.1% PTC thermal ratio, and module aperture efficiency.

PT SURYA PERTAMA INDONESIA LP-585-144MT-W Engineering BenchmarksPercentile comparison of PT SURYA PERTAMA INDONESIA LP-585-144MT-W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage585.0 WPTC/STC Retention95.1%Module Efficiency22.67%

What Do the Dataset Ranks Show for PT SURYA PERTAMA INDONESIA LP-585-144MT-W?

Summary of PT SURYA PERTAMA INDONESIA LP-585-144MT-W output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.

Rank #1,751 / 21,677

Top 8.7% STC Output

585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,698

22.67% Aperture Efficiency

Power density 226.7 W/m2 (2.76 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 58.24 V at -10 C (582.4 V string) and 59.61 V at -20 C (10 max).

8 kW Reference Array

14 Panels = 8,190 W STC

Occupies 36.1 m2 (389 sq ft) producing 7,790 W PTC; NEC 690.8 OCPD floor is 20.65 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.43 * (1 + (-0.257/100) * (-10 - 25)) = 58.24 V | OCPD = 1.56 * 13.24 = 20.65 A

Inputs from CEC Modules.csv for PT SURYA PERTAMA INDONESIA LP-585-144MT-W: Voc=53.43 V, beta_Voc=-0.257%/C, Isc=13.24 A, STC=585.0 W, Area=2.58 m2.

Result: 10 panels max on 600 V (582.4 V); 14 panels for 8 kW (389 sq ft).

What Are the Published CEC Specifications for PT SURYA PERTAMA INDONESIA LP-585-144MT-W?

Complete CEC test sheet for PT SURYA PERTAMA INDONESIA LP-585-144MT-W including Isc (13.24 A), Voc (53.43 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PT SURYA PERTAMA INDONESIA LP-585-144MT-W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 585.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 556.4 W (95.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 53.43 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.24 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 46.6 V / 12.55 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.257 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.67% (2.58 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PT SURYA PERTAMA INDONESIA LP-585-144MT-W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PT SURYA PERTAMA INDONESIA LP-585-144MT-W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.43 kW 305 sq ft $1,609 $2,721
8 kW Class 14 8.19 kW 389 sq ft $2,050 $3,466
10 kW Class 18 10.53 kW 500 sq ft $2,636 $4,457

Which Sibling Wattage & Trim Variants Belong to This PT SURYA PERTAMA INDONESIA Series?

Related PT SURYA PERTAMA INDONESIA power steps and black/silver trims consolidated into this PT SURYA PERTAMA INDONESIA LP-585-144MT-W series guide.

Sibling CEC listings grouped into the PT SURYA PERTAMA INDONESIA LP-585-144MT-W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PT SURYA PERTAMA INDONESIA LP-575-144MT-W 575.0 W 546.7 W 53.15 V 46.33 V 22.29%
PT SURYA PERTAMA INDONESIA LP-580-144MT-W 580.0 W 551.6 W 53.29 V 46.47 V 22.48%
PT SURYA PERTAMA INDONESIA LP-585-144MT-W 585.0 W 556.4 W 53.43 V 46.6 V 22.67%
PT SURYA PERTAMA INDONESIA LP-590-144MT-W 590.0 W 561.3 W 53.57 V 46.75 V 22.87%

How Many PT SURYA PERTAMA INDONESIA LP-585-144MT-W Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PT SURYA PERTAMA INDONESIA LP-585-144MT-W (53.43 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=53.43V and beta_Voc=-0.257%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 59.61 V 10 panels 596.1 V 16 panels
-10 C (14 F) 58.24 V 10 panels 582.4 V 17 panels
0 C (32 F) 56.86 V 10 panels 568.6 V 17 panels
25 C (77 F STC) 53.43 V 11 panels 587.7 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to PT SURYA PERTAMA INDONESIA LP-585-144MT-W?

Four comparable CEC modules such as FreeVolt ECP-PVGRAF-HC-BF585-144MT-B (585.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
FreeVolt ECP-PVGRAF-HC-BF585-144MT-B
FreeVolt
585.0 W Tie (0 W) 53.4 V 22.67% 95.1%
FreeVolt ECP-PVGRAF-HC-BF585-144MT-W
FreeVolt
585.0 W Tie (0 W) 53.4 V 22.67% 95.1%
Allesun Industries Inc Allesun-585-78IIMBG
Allesun Industries Inc
585.0 W Tie (0 W) 53.73 V 20.97% 94.0%
G-Star Pte Ltd GSD7G78M-585BT
G-Star Pte Ltd
585.0 W Tie (0 W) 53.73 V 21.12% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PT SURYA PERTAMA INDONESIA LP-585-144MT-W?

Evaluate PT SURYA PERTAMA INDONESIA LP-585-144MT-W (585.0 W STC, 53.43 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PT SURYA PERTAMA INDONESIA LP-585-144MT-W reaches 59.61 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of PT SURYA PERTAMA INDONESIA LP-585-144MT-W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PT SURYA PERTAMA INDONESIA LP-585-144MT-W 8 kW Residential Fit

Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare FreeVolt ECP-PVGRAF-HC-BF585-144MT-B.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 556.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT SURYA PERTAMA INDONESIA LP-585-144MT-W by PT SURYA PERTAMA INDONESIA grounded in CEC test data and NEC 690.7/690.8 limits.

How many PT SURYA PERTAMA INDONESIA LP-585-144MT-W panels fit on a 600 V winter solar string?

At -10 C (14 F), PT SURYA PERTAMA INDONESIA LP-585-144MT-W cold Voc rises from 53.43 V to 58.24 V (beta_Voc -0.257%/C), capping a 600 V string at 10 panels (582.4 V).

How much roof area does an 8 kW array of PT SURYA PERTAMA INDONESIA LP-585-144MT-W need?

An 8 kW DC system uses 14 PT SURYA PERTAMA INDONESIA LP-585-144MT-W modules (8,190 W STC / 7,790 W PTC), covering roughly 389 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does PT SURYA PERTAMA INDONESIA LP-585-144MT-W compare against FreeVolt ECP-PVGRAF-HC-BF585-144MT-B?

PT SURYA PERTAMA INDONESIA LP-585-144MT-W outputs 585.0 W STC (53.43 V Voc, rank #1,751 of 21,677), while FreeVolt ECP-PVGRAF-HC-BF585-144MT-B delivers 585.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.