PT SURYA PERTAMA INDONESIA LP-560-144MT-W is a 560.0 W STC (532.1 W PTC) Mono-c-Si solar module ranking #2,404 of 21,677 CEC listings (top 11.8%; higher than 88.2% of peers). It delivers 21.71% efficiency, 52.73 V Voc at 25 C, and 57.47 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 560.0 W
- PTC Wattage
- 532.1 W
- Voc @ 25C
- 52.73 V
- Efficiency
- 21.71%
How Does PT SURYA PERTAMA INDONESIA LP-560-144MT-W Compare Against Peer CEC Listings?
Solar engineering breakdown for PT SURYA PERTAMA INDONESIA LP-560-144MT-W: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from PT SURYA PERTAMA INDONESIA and peers, PT SURYA PERTAMA INDONESIA LP-560-144MT-W stands 150.0 W above the 410.0 W Mono-c-Si median and strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677). Sizing 6 kW (11 panels) to 10 kW (18 panels) yields $1,542-$2,523/yr in baseline US bill offset. Higher 52.73 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does PT SURYA PERTAMA INDONESIA LP-560-144MT-W Fall Across Listed CEC Models?
Distribution marker showing PT SURYA PERTAMA INDONESIA LP-560-144MT-W (560.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define PT SURYA PERTAMA INDONESIA LP-560-144MT-W?
Dataset percentiles tracking PT SURYA PERTAMA INDONESIA LP-560-144MT-W power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for PT SURYA PERTAMA INDONESIA LP-560-144MT-W?
Benchmark highlights for PT SURYA PERTAMA INDONESIA LP-560-144MT-W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 11.8% STC Output
560.0 W STC (+175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.71% Aperture Efficiency
Power density 217.1 W/m2 (1.80 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 57.47 V at -10 C (574.7 V string) and 58.83 V at -20 C (10 max).
15 Panels = 8,400 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,982 W PTC; NEC 690.8 OCPD floor is 20.03 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.73 * (1 + (-0.257/100) * (-10 - 25)) = 57.47 V | OCPD = 1.56 * 12.84 = 20.03 A
Inputs from CEC Modules.csv for PT SURYA PERTAMA INDONESIA LP-560-144MT-W: Voc=52.73 V, beta_Voc=-0.257%/C, Isc=12.84 A, STC=560.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (574.7 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for PT SURYA PERTAMA INDONESIA LP-560-144MT-W?
Official CEC datasheet figures for PT SURYA PERTAMA INDONESIA LP-560-144MT-W (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 560.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 532.1 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.73 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 12.84 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.9 V / 12.2 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.257 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.71% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many PT SURYA PERTAMA INDONESIA LP-560-144MT-W Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many PT SURYA PERTAMA INDONESIA LP-560-144MT-W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.16 kW | 305 sq ft | $1,542 | $2,607 |
| 8 kW Class | 15 | 8.4 kW | 417 sq ft | $2,102 | $3,555 |
| 10 kW Class | 18 | 10.08 kW | 500 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This PT SURYA PERTAMA INDONESIA Series?
Consolidated PT SURYA PERTAMA INDONESIA wattage variants sharing the PT SURYA PERTAMA INDONESIA LP-560-144MT-W mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PT SURYA PERTAMA INDONESIA LP-550-144MT-W | 550.0 W | 522.4 W | 52.45 V | 45.6 V | 21.32% |
| PT SURYA PERTAMA INDONESIA LP-555-144MT-W | 555.0 W | 527.3 W | 52.59 V | 45.75 V | 21.51% |
| PT SURYA PERTAMA INDONESIA LP-560-144MT-W | 560.0 W | 532.1 W | 52.73 V | 45.9 V | 21.71% |
| PT SURYA PERTAMA INDONESIA LP-565-144MT-W | 565.0 W | 537.0 W | 52.87 V | 46.04 V | 21.9% |
| PT SURYA PERTAMA INDONESIA LP-570-144MT-W | 570.0 W | 541.9 W | 53.01 V | 46.19 V | 22.09% |
How Many PT SURYA PERTAMA INDONESIA LP-560-144MT-W Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on PT SURYA PERTAMA INDONESIA LP-560-144MT-W (57.47 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 58.83 V | 10 panels | 588.3 V | 16 panels |
| -10 C (14 F) | 57.47 V | 10 panels | 574.7 V | 17 panels |
| 0 C (32 F) | 56.12 V | 10 panels | 561.2 V | 17 panels |
| 25 C (77 F STC) | 52.73 V | 11 panels | 580.0 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to PT SURYA PERTAMA INDONESIA LP-560-144MT-W?
Competing CEC solar panels closest to PT SURYA PERTAMA INDONESIA LP-560-144MT-W in nameplate wattage and Voc, starting with FreeVolt ECP-PVGRAF-HC-BF560-144MT-B.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| FreeVolt ECP-PVGRAF-HC-BF560-144MT-B FreeVolt |
560.0 W | Tie (0 W) | 52.7 V | 21.71% | 95.0% |
| FreeVolt ECP-PVGRAF-HC-BF560-144MT-W FreeVolt |
560.0 W | Tie (0 W) | 52.7 V | 21.71% | 95.0% |
| Auxin Solar AXN10M560W Auxin Solar |
560.0 W | Tie (0 W) | 52.48 V | 21.88% | 91.8% |
| Boviet Solar Technology Co Ltd BVM7612M-560-H-HC Boviet Solar Technology Co Ltd |
560.0 W | Tie (0 W) | 51.66 V | 21.71% | 95.0% |
What Are the Design Limits and Best-Fit Uses for PT SURYA PERTAMA INDONESIA LP-560-144MT-W?
Evaluate PT SURYA PERTAMA INDONESIA LP-560-144MT-W (560.0 W STC, 52.73 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PT SURYA PERTAMA INDONESIA LP-560-144MT-W reaches 58.83 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of PT SURYA PERTAMA INDONESIA LP-560-144MT-W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PT SURYA PERTAMA INDONESIA LP-560-144MT-W 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare FreeVolt ECP-PVGRAF-HC-BF560-144MT-B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 532.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PT SURYA PERTAMA INDONESIA LP-560-144MT-W by PT SURYA PERTAMA INDONESIA grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for PT SURYA PERTAMA INDONESIA LP-560-144MT-W?
Multiplying PT SURYA PERTAMA INDONESIA LP-560-144MT-W's 12.84 A short-circuit current by 1.56 equals 20.03 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can PT SURYA PERTAMA INDONESIA LP-560-144MT-W pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 57.47 V cold Voc at 14 F and handles 12.84 A Isc; string inverters cap PT SURYA PERTAMA INDONESIA LP-560-144MT-W at 10 panels on 600 V.
Is PT SURYA PERTAMA INDONESIA LP-560-144MT-W eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PT SURYA PERTAMA INDONESIA LP-560-144MT-W rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)