PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 is a 585.0 W STC (557.4 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.67% efficiency, 51.62 V Voc at 25 C, and 56.01 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 585.0 W
- PTC Wattage
- 557.4 W
- Voc @ 25C
- 51.62 V
- Efficiency
- 22.67%
How Does PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 (Mono-c-Si) residential solar systems.
PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 delivers 226.7 W/m2 (2.76 percentage points above 19.91% CEC median) and strong 95.3% PTC-to-STC heat retention (#237 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 57.26 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with AE Solar GmbH AE585CMD-144BDS (585.0 W).
Where Does PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 Fall Across Listed CEC Models?
Comparison of PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 (585.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define PT JAYA ELECTRICAL ENERGY JAYAEGN585-144?
Relative ranking of PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 across nameplate watts, 95.3% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for PT JAYA ELECTRICAL ENERGY JAYAEGN585-144?
Summary of PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.
Top 8.7% STC Output
585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.67% Aperture Efficiency
Power density 226.7 W/m2 (2.76 percentage points above 19.91% CEC median). PTC/STC ratio: 95.3% (rank #237).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 56.01 V at -10 C (560.1 V string) and 57.26 V at -20 C (10 max).
14 Panels = 8,190 W STC
Occupies 36.1 m2 (389 sq ft) producing 7,804 W PTC; NEC 690.8 OCPD floor is 22.04 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 51.62 * (1 + (-0.243/100) * (-10 - 25)) = 56.01 V | OCPD = 1.56 * 14.13 = 22.04 A
Inputs from CEC Modules.csv for PT JAYA ELECTRICAL ENERGY JAYAEGN585-144: Voc=51.62 V, beta_Voc=-0.243%/C, Isc=14.13 A, STC=585.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (560.1 V); 14 panels for 8 kW (389 sq ft).
What Are the Published CEC Specifications for PT JAYA ELECTRICAL ENERGY JAYAEGN585-144?
Complete CEC test sheet for PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 including Isc (14.13 A), Voc (51.62 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 585.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 557.4 W (95.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 51.62 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.13 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.99 V / 13.61 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.243 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.67% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PT JAYA ELECTRICAL ENERGY JAYAEGN585-144.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.43 kW | 305 sq ft | $1,609 | $2,721 |
| 8 kW Class | 14 | 8.19 kW | 389 sq ft | $2,050 | $3,466 |
| 10 kW Class | 18 | 10.53 kW | 500 sq ft | $2,636 | $4,457 |
Which Sibling Wattage & Trim Variants Belong to This PT JAYA ELECTRICAL ENERGY Series?
Related PT JAYA ELECTRICAL ENERGY power steps and black/silver trims consolidated into this PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PT JAYA ELECTRICAL ENERGY JAYAEGN575-144 | 575.0 W | 547.7 W | 51.31 V | 42.69 V | 22.29% |
| PT JAYA ELECTRICAL ENERGY JAYAEGN580-144 | 580.0 W | 552.6 W | 51.47 V | 42.84 V | 22.48% |
| PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 | 585.0 W | 557.4 W | 51.62 V | 42.99 V | 22.67% |
| PT JAYA ELECTRICAL ENERGY JAYAEGN590-144 | 590.0 W | 562.3 W | 51.78 V | 43.14 V | 22.87% |
| PT JAYA ELECTRICAL ENERGY JAYAEGN595-144 | 595.0 W | 567.2 W | 51.93 V | 43.29 V | 23.06% |
How Many PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 (51.62 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 57.26 V | 10 panels | 572.6 V | 17 panels |
| -10 C (14 F) | 56.01 V | 10 panels | 560.1 V | 17 panels |
| 0 C (32 F) | 54.76 V | 10 panels | 547.6 V | 18 panels |
| 25 C (77 F STC) | 51.62 V | 11 panels | 567.8 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to PT JAYA ELECTRICAL ENERGY JAYAEGN585-144?
Four comparable CEC modules such as AE Solar GmbH AE585CMD-144BDS (585.0 W) for side-by-side solar quote checks. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AE Solar GmbH AE585CMD-144BDS AE Solar GmbH |
585.0 W | Tie (0 W) | 51.6 V | 22.67% | 95.3% |
| DE SOLAR(S) PTE LTD DE585-144BG-182S-N/WW DE SOLAR(S) PTE LTD |
585.0 W | Tie (0 W) | 51.6 V | 22.67% | 95.3% |
| Chint New Energy Technology Co Ltd CHSM72N-HC-585 Chint New Energy Technology Co Ltd |
585.0 W | Tie (0 W) | 51.3 V | 22.67% | 94.7% |
| ELITE Solar ET-N772TBH585GB ELITE Solar |
585.0 W | Tie (0 W) | 52.28 V | 22.67% | 94.8% |
What Are the Design Limits and Best-Fit Uses for PT JAYA ELECTRICAL ENERGY JAYAEGN585-144?
Evaluate PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 (585.0 W STC, 51.62 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 reaches 57.26 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 8 kW Residential Fit
Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AE Solar GmbH AE585CMD-144BDS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 557.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 by PT JAYA ELECTRICAL ENERGY grounded in CEC test data and NEC 690.7/690.8 limits.
How many PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 panels fit on a 600 V winter solar string?
At -10 C (14 F), PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 cold Voc rises from 51.62 V to 56.01 V (beta_Voc -0.243%/C), capping a 600 V string at 10 panels (560.1 V).
How much roof area does an 8 kW array of PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 need?
An 8 kW DC system uses 14 PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 modules (8,190 W STC / 7,804 W PTC), covering roughly 389 sq ft and saving ~$2,050/yr at 18.54 c/kWh.
How does PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 compare against AE Solar GmbH AE585CMD-144BDS?
PT JAYA ELECTRICAL ENERGY JAYAEGN585-144 outputs 585.0 W STC (51.62 V Voc, rank #1,751 of 21,677), while AE Solar GmbH AE585CMD-144BDS delivers 585.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)