PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) — CEC Solar Module Specifications

Manufacturer: PT JAYA ELECTRICAL ENERGY Registry: CEC Verified Engineering Specification

PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) is a 420.0 W STC (398.3 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 21.54% efficiency, 39.66 V Voc at 25 C, and 42.99 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
420.0 W
PTC Wattage
398.3 W
Voc @ 25C
39.66 V
Efficiency
21.54%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) Compare Against Peer CEC Listings?

How PT JAYA ELECTRICAL ENERGY PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) handles rooftop heat (398.3 W PTC), 8 kW sizing, and cold winter string voltage.

PT JAYA ELECTRICAL ENERGY builds the PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 215.4 W/m2 (1.63 percentage points above 19.91% CEC median). Compared against AE Solar GmbH AE420CMD-108BDE (420.0 W), this model holds strong 94.8% PTC-to-STC heat retention (#1,790 of 21,677). Lower 39.66 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.18 A overcurrent floor served by a 25 A breaker.

Where Does PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) Fall Across Listed CEC Models?

Where PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) (420.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) (420.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPT JAYA ELECTRICAL: 420.0 W

What Dataset Percentiles Define PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B)?

Percentile placement of PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) across power density (215.4 W/m2), thermal retention, and nameplate STC wattage.

PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) Engineering BenchmarksPercentile comparison of PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage420.0 WPTC/STC Retention94.8%Module Efficiency21.54%

What Do the Dataset Ranks Show for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B)?

Four critical engineering numbers homeowners and solar installers check first when reviewing PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) specifications.

Rank #7,910 / 21,677

Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,253

21.54% Aperture Efficiency

Power density 215.4 W/m2 (1.63 percentage points above 19.91% CEC median). PTC/STC ratio: 94.8% (rank #1,790).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.99 V at -10 C (558.9 V string) and 43.94 V at -20 C (13 max).

8 kW Reference Array

20 Panels = 8,400 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,966 W PTC; NEC 690.8 OCPD floor is 21.18 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.66 * (1 + (-0.24/100) * (-10 - 25)) = 42.99 V | OCPD = 1.56 * 13.58 = 21.18 A

Inputs from CEC Modules.csv for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B): Voc=39.66 V, beta_Voc=-0.24%/C, Isc=13.58 A, STC=420.0 W, Area=1.95 m2.

Result: 13 panels max on 600 V (558.9 V); 20 panels for 8 kW (420 sq ft).

What Are the Published CEC Specifications for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B).

Official California Energy Commission (NREL SAM) test parameters for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 420.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 398.3 W (94.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.66 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.58 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.63 V / 13.28 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.24 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.54% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) (420.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.3 kW 315 sq ft $1,577 $2,666
8 kW Class 20 8.4 kW 420 sq ft $2,102 $3,555
10 kW Class 24 10.08 kW 504 sq ft $2,523 $4,266

How Many PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) Modules Fit in a Cold-Weather String?

Maximum series module counts for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=39.66V and beta_Voc=-0.24%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.94 V 13 panels 571.2 V 22 panels
-10 C (14 F) 42.99 V 13 panels 558.9 V 23 panels
0 C (32 F) 42.04 V 14 panels 588.6 V 23 panels
25 C (77 F STC) 39.66 V 15 panels 594.9 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B)?

Alternative CEC solar modules from competing brands near PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) (420.0 W), including AE Solar GmbH AE420CMD-108BDE.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AE Solar GmbH AE420CMD-108BDE
AE Solar GmbH
420.0 W Tie (0 W) 39.7 V 21.54% 94.8%
DE SOLAR(S) PTE LTD DE420-108BG-182S-N/BB
DE SOLAR(S) PTE LTD
420.0 W Tie (0 W) 39.7 V 21.54% 94.8%
Aptos Solar Technology LLC DNA-108-MFN10-420W
Aptos Solar Technology LLC
420.0 W Tie (0 W) 38.5 V 21.65% 95.0%
Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-420
Elin Energy (Sirius PV)
420.0 W Tie (0 W) 38.5 V 21.65% 94.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B)?

Evaluate PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) (420.0 W STC, 39.66 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) reaches 43.94 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AE Solar GmbH AE420CMD-108BDE.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 398.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) by PT JAYA ELECTRICAL ENERGY grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B)?

Multiplying PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B)'s 13.58 A short-circuit current by 1.56 equals 21.18 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.99 V cold Voc at 14 F and handles 13.58 A Isc; string inverters cap PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) at 13 panels on 600 V.

Is PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B) rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.