PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) — CEC Solar Module Specifications

Manufacturer: PT JAYA ELECTRICAL ENERGY Registry: CEC Verified Engineering Specification

PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) is a 435.0 W STC (412.8 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 22.31% efficiency, 40.1 V Voc at 25 C, and 43.47 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
435.0 W
PTC Wattage
412.8 W
Voc @ 25C
40.1 V
Efficiency
22.31%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) Compare Against Peer CEC Listings?

Solar engineering breakdown for PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B): PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from PT JAYA ELECTRICAL ENERGY and peers, PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) stands 25.0 W above the 410.0 W Mono-c-Si median and strong 94.9% PTC-to-STC heat retention (#1,466 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,524-$2,505/yr in baseline US bill offset. Mid-range 40.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) Fall Across Listed CEC Models?

Distribution marker showing PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) (435.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) (435.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPT JAYA ELECTRICAL: 435.0 W

What Dataset Percentiles Define PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B)?

Dataset percentiles tracking PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) power output, thermal retention ratio, and aperture efficiency against 21,677 models.

PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) Engineering BenchmarksPercentile comparison of PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage435.0 WPTC/STC Retention94.9%Module Efficiency22.31%

What Do the Dataset Ranks Show for PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B)?

Benchmark highlights for PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #6,850 / 21,677

Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,379

22.31% Aperture Efficiency

Power density 223.1 W/m2 (2.40 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.47 V at -10 C (565.1 V string) and 44.43 V at -20 C (13 max).

8 kW Reference Array

19 Panels = 8,265 W STC

Occupies 37.0 m2 (399 sq ft) producing 7,843 W PTC; NEC 690.8 OCPD floor is 21.65 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.1 * (1 + (-0.24/100) * (-10 - 25)) = 43.47 V | OCPD = 1.56 * 13.88 = 21.65 A

Inputs from CEC Modules.csv for PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B): Voc=40.1 V, beta_Voc=-0.24%/C, Isc=13.88 A, STC=435.0 W, Area=1.95 m2.

Result: 13 panels max on 600 V (565.1 V); 19 panels for 8 kW (399 sq ft).

What Are the Published CEC Specifications for PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B)?

Official CEC datasheet figures for PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 435.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 412.8 W (94.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.88 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.04 V / 13.58 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.24 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.31% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.09 kW 294 sq ft $1,524 $2,577
8 kW Class 19 8.27 kW 399 sq ft $2,070 $3,500
10 kW Class 23 10.01 kW 483 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This PT JAYA ELECTRICAL ENERGY Series?

Consolidated PT JAYA ELECTRICAL ENERGY wattage variants sharing the PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) mechanical and cell layout.

Sibling CEC listings grouped into the PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PT JAYA ELECTRICAL ENERGY JAYAEGN425-108(B) 425.0 W 403.1 W 39.81 V 31.77 V 21.79%
PT JAYA ELECTRICAL ENERGY JAYAEGN430-108(B) 430.0 W 408.0 W 39.95 V 31.9 V 22.05%
PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) 435.0 W 412.8 W 40.1 V 32.04 V 22.31%
PT JAYA ELECTRICAL ENERGY JAYAEGN440-108(B) 440.0 W 417.7 W 40.24 V 32.17 V 22.56%

How Many PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) (43.47 V at 14 F).

Computed from Voc=40.1V and beta_Voc=-0.24%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.43 V 13 panels 577.6 V 22 panels
-10 C (14 F) 43.47 V 13 panels 565.1 V 23 panels
0 C (32 F) 42.51 V 14 panels 595.1 V 23 panels
25 C (77 F STC) 40.1 V 14 panels 561.4 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B)?

Competing CEC solar panels closest to PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) in nameplate wattage and Voc, starting with AE Solar GmbH AE435CMD-108BDE.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AE Solar GmbH AE435CMD-108BDE
AE Solar GmbH
435.0 W Tie (0 W) 40.1 V 22.31% 94.9%
DE SOLAR(S) PTE LTD DE435-108BG-182S-N/BB
DE SOLAR(S) PTE LTD
435.0 W Tie (0 W) 40.1 V 22.31% 94.9%
CertainTeed CTM10435HC11-06
CertainTeed
435.0 W Tie (0 W) 40.95 V 20.14% 93.7%
Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435
Elin Energy (Sirius PV)
435.0 W Tie (0 W) 39.1 V 22.42% 95.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B)?

Evaluate PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) (435.0 W STC, 40.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) reaches 44.43 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 399 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (399 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) 8 kW Residential Fit

Needs 19 modules (399 sq ft) with a 25 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AE Solar GmbH AE435CMD-108BDE.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 412.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) by PT JAYA ELECTRICAL ENERGY grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B)?

Multiplying PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B)'s 13.88 A short-circuit current by 1.56 equals 21.65 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.47 V cold Voc at 14 F and handles 13.88 A Isc; string inverters cap PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) at 13 panels on 600 V.

Is PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B) rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.