AE Solar GmbH AE585CMD-144BDS is a 585.0 W STC (557.5 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.67% efficiency, 51.6 V Voc at 25 C, and 55.99 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 585.0 W
- PTC Wattage
- 557.5 W
- Voc @ 25C
- 51.6 V
- Efficiency
- 22.67%
How Does AE Solar GmbH AE585CMD-144BDS Compare Against Peer CEC Listings?
Solar engineering breakdown for AE Solar GmbH AE585CMD-144BDS: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from AE Solar GmbH and peers, AE Solar GmbH AE585CMD-144BDS stands 175.0 W above the 410.0 W Mono-c-Si median and strong 95.3% PTC-to-STC heat retention (#237 of 21,677). Sizing 6 kW (11 panels) to 10 kW (18 panels) yields $1,609-$2,636/yr in baseline US bill offset. Higher 51.6 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does AE Solar GmbH AE585CMD-144BDS Fall Across Listed CEC Models?
Distribution marker showing AE Solar GmbH AE585CMD-144BDS (585.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define AE Solar GmbH AE585CMD-144BDS?
Dataset percentiles tracking AE Solar GmbH AE585CMD-144BDS power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for AE Solar GmbH AE585CMD-144BDS?
Benchmark highlights for AE Solar GmbH AE585CMD-144BDS covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 8.7% STC Output
585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.67% Aperture Efficiency
Power density 226.7 W/m2 (2.76 percentage points above 19.91% CEC median). PTC/STC ratio: 95.3% (rank #237).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 55.99 V at -10 C (559.9 V string) and 57.24 V at -20 C (10 max).
14 Panels = 8,190 W STC
Occupies 36.1 m2 (389 sq ft) producing 7,805 W PTC; NEC 690.8 OCPD floor is 22.04 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 51.6 * (1 + (-0.243/100) * (-10 - 25)) = 55.99 V | OCPD = 1.56 * 14.13 = 22.04 A
Inputs from CEC Modules.csv for AE Solar GmbH AE585CMD-144BDS: Voc=51.6 V, beta_Voc=-0.243%/C, Isc=14.13 A, STC=585.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (559.9 V); 14 panels for 8 kW (389 sq ft).
What Are the Published CEC Specifications for AE Solar GmbH AE585CMD-144BDS?
Official CEC datasheet figures for AE Solar GmbH AE585CMD-144BDS (Mono-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 585.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 557.5 W (95.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 51.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.13 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 43.0 V / 13.61 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.243 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.67% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many AE Solar GmbH AE585CMD-144BDS Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many AE Solar GmbH AE585CMD-144BDS modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.43 kW | 305 sq ft | $1,609 | $2,721 |
| 8 kW Class | 14 | 8.19 kW | 389 sq ft | $2,050 | $3,466 |
| 10 kW Class | 18 | 10.53 kW | 500 sq ft | $2,636 | $4,457 |
Which Sibling Wattage & Trim Variants Belong to This AE Solar GmbH Series?
Consolidated AE Solar GmbH wattage variants sharing the AE Solar GmbH AE585CMD-144BDS mechanical and cell layout. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AE Solar GmbH AE575CMD-144BDS | 575.0 W | 547.7 W | 51.3 V | 42.7 V | 22.29% |
| AE Solar GmbH AE580CMD-144BDS | 580.0 W | 552.6 W | 51.5 V | 42.8 V | 22.48% |
| AE Solar GmbH AE585CMD-144BDS | 585.0 W | 557.5 W | 51.6 V | 43.0 V | 22.67% |
| AE Solar GmbH AE590CMD-144BDS | 590.0 W | 562.3 W | 51.8 V | 43.1 V | 22.87% |
| AE Solar GmbH AE595CMD-144BDS | 595.0 W | 567.2 W | 51.9 V | 43.3 V | 23.06% |
How Many AE Solar GmbH AE585CMD-144BDS Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on AE Solar GmbH AE585CMD-144BDS (55.99 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 57.24 V | 10 panels | 572.4 V | 17 panels |
| -10 C (14 F) | 55.99 V | 10 panels | 559.9 V | 17 panels |
| 0 C (32 F) | 54.73 V | 10 panels | 547.3 V | 18 panels |
| 25 C (77 F STC) | 51.6 V | 11 panels | 567.6 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to AE Solar GmbH AE585CMD-144BDS?
Competing CEC solar panels closest to AE Solar GmbH AE585CMD-144BDS in nameplate wattage and Voc, starting with DE SOLAR(S) PTE LTD DE585-144BG-182S-N/WW.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DE SOLAR(S) PTE LTD DE585-144BG-182S-N/WW DE SOLAR(S) PTE LTD |
585.0 W | Tie (0 W) | 51.6 V | 22.67% | 95.3% |
| Chint New Energy Technology Co Ltd CHSM72N-HC-585 Chint New Energy Technology Co Ltd |
585.0 W | Tie (0 W) | 51.3 V | 22.67% | 94.7% |
| ELITE Solar ET-N772TBH585GB ELITE Solar |
585.0 W | Tie (0 W) | 52.28 V | 22.67% | 94.8% |
| ELITE Solar ET-N772TBH585GL ELITE Solar |
585.0 W | Tie (0 W) | 52.28 V | 22.67% | 94.8% |
What Are the Design Limits and Best-Fit Uses for AE Solar GmbH AE585CMD-144BDS?
Evaluate AE Solar GmbH AE585CMD-144BDS (585.0 W STC, 51.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AE Solar GmbH AE585CMD-144BDS reaches 57.24 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of AE Solar GmbH AE585CMD-144BDS carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AE Solar GmbH AE585CMD-144BDS 8 kW Residential Fit
Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare DE SOLAR(S) PTE LTD DE585-144BG-182S-N/WW.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 557.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AE Solar GmbH AE585CMD-144BDS by AE Solar GmbH grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for AE Solar GmbH AE585CMD-144BDS?
Multiplying AE Solar GmbH AE585CMD-144BDS's 14.13 A short-circuit current by 1.56 equals 22.04 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can AE Solar GmbH AE585CMD-144BDS pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 55.99 V cold Voc at 14 F and handles 14.13 A Isc; string inverters cap AE Solar GmbH AE585CMD-144BDS at 10 panels on 600 V.
Is AE Solar GmbH AE585CMD-144BDS eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AE Solar GmbH AE585CMD-144BDS rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)