AE Solar GmbH AE570CMD-144BDS — CEC Solar Module Specifications

Manufacturer: AE Solar GmbH Registry: CEC Verified Engineering Specification

AE Solar GmbH AE570CMD-144BDS is a 570.0 W STC (542.9 W PTC) Mono-c-Si solar module ranking #2,154 of 21,677 CEC listings (top 10.5%; higher than 89.5% of peers). It delivers 22.09% efficiency, 51.2 V Voc at 25 C, and 55.55 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
570.0 W
PTC Wattage
542.9 W
Voc @ 25C
51.2 V
Efficiency
22.09%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AE Solar GmbH AE570CMD-144BDS Compare Against Peer CEC Listings?

How AE Solar GmbH AE Solar GmbH AE570CMD-144BDS handles rooftop heat (542.9 W PTC), 8 kW sizing, and cold winter string voltage.

AE Solar GmbH builds the AE Solar GmbH AE570CMD-144BDS (Mono-c-Si) as a large-format commercial and ground-mount module delivering 220.9 W/m2 (2.18 percentage points above 19.91% CEC median). Compared against DE SOLAR(S) PTE LTD DE570-144BG-182S-N/WW (570.0 W), this model holds strong 95.2% PTC-to-STC heat retention (#399 of 21,677). Higher 51.2 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 21.7 A overcurrent floor served by a 25 A breaker.

Where Does AE Solar GmbH AE570CMD-144BDS Fall Across Listed CEC Models?

Where AE Solar GmbH AE570CMD-144BDS (570.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AE Solar GmbH AE570CMD-144BDS (570.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAE Solar GmbH AE57: 570.0 W

What Dataset Percentiles Define AE Solar GmbH AE570CMD-144BDS?

Percentile placement of AE Solar GmbH AE570CMD-144BDS across power density (220.9 W/m2), thermal retention, and nameplate STC wattage.

AE Solar GmbH AE570CMD-144BDS Engineering BenchmarksPercentile comparison of AE Solar GmbH AE570CMD-144BDS wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage570.0 WPTC/STC Retention95.2%Module Efficiency22.09%

What Do the Dataset Ranks Show for AE Solar GmbH AE570CMD-144BDS?

Four critical engineering numbers homeowners and solar installers check first when reviewing AE Solar GmbH AE570CMD-144BDS specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #2,154 / 21,677

Top 10.5% STC Output

570.0 W STC (+185.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,842

22.09% Aperture Efficiency

Power density 220.9 W/m2 (2.18 percentage points above 19.91% CEC median). PTC/STC ratio: 95.2% (rank #399).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.55 V at -10 C (555.5 V string) and 56.8 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,550 W STC

Occupies 38.7 m2 (417 sq ft) producing 8,144 W PTC; NEC 690.8 OCPD floor is 21.7 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 51.2 * (1 + (-0.243/100) * (-10 - 25)) = 55.55 V | OCPD = 1.56 * 13.91 = 21.7 A

Inputs from CEC Modules.csv for AE Solar GmbH AE570CMD-144BDS: Voc=51.2 V, beta_Voc=-0.243%/C, Isc=13.91 A, STC=570.0 W, Area=2.58 m2.

Result: 10 panels max on 600 V (555.5 V); 15 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for AE Solar GmbH AE570CMD-144BDS?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for AE Solar GmbH AE570CMD-144BDS.

Official California Energy Commission (NREL SAM) test parameters for AE Solar GmbH AE570CMD-144BDS.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 570.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 542.9 W (95.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 51.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.91 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.5 V / 13.4 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.243 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.09% (2.58 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many AE Solar GmbH AE570CMD-144BDS Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using AE Solar GmbH AE570CMD-144BDS (570.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.27 kW 305 sq ft $1,569 $2,654
8 kW Class 15 8.55 kW 417 sq ft $2,140 $3,619
10 kW Class 18 10.26 kW 500 sq ft $2,568 $4,342

How Many AE Solar GmbH AE570CMD-144BDS Modules Fit in a Cold-Weather String?

Maximum series module counts for AE Solar GmbH AE570CMD-144BDS from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=51.2V and beta_Voc=-0.243%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.8 V 10 panels 568.0 V 17 panels
-10 C (14 F) 55.55 V 10 panels 555.5 V 18 panels
0 C (32 F) 54.31 V 11 panels 597.4 V 18 panels
25 C (77 F STC) 51.2 V 11 panels 563.2 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to AE Solar GmbH AE570CMD-144BDS?

Alternative CEC solar modules from competing brands near AE Solar GmbH AE570CMD-144BDS (570.0 W), including DE SOLAR(S) PTE LTD DE570-144BG-182S-N/WW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DE SOLAR(S) PTE LTD DE570-144BG-182S-N/WW
DE SOLAR(S) PTE LTD
570.0 W Tie (0 W) 51.2 V 22.09% 95.2%
Aptos Solar Technology LLC DNA-144-BFN10-570W-DG
Aptos Solar Technology LLC
570.0 W Tie (0 W) 50.74 V 22.09% 94.9%
AEG SOLAR ENERGY SRL ALPS72D30-570/TP
AEG SOLAR ENERGY SRL
570.0 W Tie (0 W) 52.1 V 22.09% 94.3%
G-Star Pte Ltd GSD7S72T-570BT
G-Star Pte Ltd
570.0 W Tie (0 W) 52.31 V 22.27% 95.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AE Solar GmbH AE570CMD-144BDS?

Evaluate AE Solar GmbH AE570CMD-144BDS (570.0 W STC, 51.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AE Solar GmbH AE570CMD-144BDS reaches 56.8 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of AE Solar GmbH AE570CMD-144BDS carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AE Solar GmbH AE570CMD-144BDS 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,140/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare DE SOLAR(S) PTE LTD DE570-144BG-182S-N/WW.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 542.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AE Solar GmbH AE570CMD-144BDS by AE Solar GmbH grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for AE Solar GmbH AE570CMD-144BDS?

Multiplying AE Solar GmbH AE570CMD-144BDS's 13.91 A short-circuit current by 1.56 equals 21.7 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can AE Solar GmbH AE570CMD-144BDS pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 55.55 V cold Voc at 14 F and handles 13.91 A Isc; string inverters cap AE Solar GmbH AE570CMD-144BDS at 10 panels on 600 V.

Is AE Solar GmbH AE570CMD-144BDS eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AE Solar GmbH AE570CMD-144BDS rely on utility bill offset (~$2,140/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.