PT IDN SOLAR TECH NUSA120H-315MB is a 315.0 W STC (293.6 W PTC) Mono-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 18.64% efficiency, 40.1 V Voc at 25 C, and 44.58 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 315.0 W
- PTC Wattage
- 293.6 W
- Voc @ 25C
- 40.1 V
- Efficiency
- 18.64%
How Does PT IDN SOLAR TECH NUSA120H-315MB Compare Against Peer CEC Listings?
Solar engineering breakdown for PT IDN SOLAR TECH NUSA120H-315MB: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from PT IDN SOLAR TECH and peers, PT IDN SOLAR TECH NUSA120H-315MB stands 95.0 W below the 410.0 W Mono-c-Si median and strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Sizing 6 kW (20 panels) to 10 kW (32 panels) yields $1,577-$2,523/yr in baseline US bill offset. Mid-range 40.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does PT IDN SOLAR TECH NUSA120H-315MB Fall Across Listed CEC Models?
Distribution marker showing PT IDN SOLAR TECH NUSA120H-315MB (315.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define PT IDN SOLAR TECH NUSA120H-315MB?
Dataset percentiles tracking PT IDN SOLAR TECH NUSA120H-315MB power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for PT IDN SOLAR TECH NUSA120H-315MB?
Benchmark highlights for PT IDN SOLAR TECH NUSA120H-315MB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
315.0 W STC · Higher Than 27.3%
315.0 W STC (-70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.64% Aperture Efficiency
Power density 186.4 W/m2 (1.27 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.58 V at -10 C (579.5 V string) and 45.86 V at -20 C (13 max).
26 Panels = 8,190 W STC
Occupies 43.9 m2 (473 sq ft) producing 7,634 W PTC; NEC 690.8 OCPD floor is 15.52 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.1 * (1 + (-0.319/100) * (-10 - 25)) = 44.58 V | OCPD = 1.56 * 9.95 = 15.52 A
Inputs from CEC Modules.csv for PT IDN SOLAR TECH NUSA120H-315MB: Voc=40.1 V, beta_Voc=-0.319%/C, Isc=9.95 A, STC=315.0 W, Area=1.69 m2.
Result: 13 panels max on 600 V (579.5 V); 26 panels for 8 kW (473 sq ft).
What Are the Published CEC Specifications for PT IDN SOLAR TECH NUSA120H-315MB?
Official CEC datasheet figures for PT IDN SOLAR TECH NUSA120H-315MB (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 315.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 293.6 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.95 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.4 V / 9.44 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.319 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.64% (1.69 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many PT IDN SOLAR TECH NUSA120H-315MB Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many PT IDN SOLAR TECH NUSA120H-315MB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.3 kW | 364 sq ft | $1,577 | $2,666 |
| 8 kW Class | 26 | 8.19 kW | 473 sq ft | $2,050 | $3,466 |
| 10 kW Class | 32 | 10.08 kW | 582 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This PT IDN SOLAR TECH Series?
Consolidated PT IDN SOLAR TECH wattage variants sharing the PT IDN SOLAR TECH NUSA120H-315MB mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PT IDN SOLAR TECH NUSA120H-310MB | 310.0 W | 288.9 W | 39.8 V | 33.1 V | 18.34% |
| PT IDN SOLAR TECH NUSA120H-315MB | 315.0 W | 293.6 W | 40.1 V | 33.4 V | 18.64% |
| PT IDN SOLAR TECH NUSA120H-320MB | 320.0 W | 298.4 W | 40.4 V | 33.6 V | 18.93% |
How Many PT IDN SOLAR TECH NUSA120H-315MB Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on PT IDN SOLAR TECH NUSA120H-315MB (44.58 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.86 V | 13 panels | 596.2 V | 21 panels |
| -10 C (14 F) | 44.58 V | 13 panels | 579.5 V | 22 panels |
| 0 C (32 F) | 43.3 V | 13 panels | 562.9 V | 23 panels |
| 25 C (77 F STC) | 40.1 V | 14 panels | 561.4 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to PT IDN SOLAR TECH NUSA120H-315MB?
Competing CEC solar panels closest to PT IDN SOLAR TECH NUSA120H-315MB in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-M6/60315.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/60315 GCL System Integration Technology Co Ltd |
315.0 W | Tie (0 W) | 40.1 V | 19.33% | 91.3% |
| AXITEC AC-315MH/120S AXITEC |
315.0 W | Tie (0 W) | 39.74 V | 18.96% | 93.0% |
| AXITEC AC-315MH/120V AXITEC |
315.0 W | Tie (0 W) | 39.74 V | 18.96% | 93.0% |
| CertainTeed CT315HC11-04 CertainTeed |
315.0 W | Tie (0 W) | 39.74 V | 19.58% | 92.2% |
What Are the Design Limits and Best-Fit Uses for PT IDN SOLAR TECH NUSA120H-315MB?
Evaluate PT IDN SOLAR TECH NUSA120H-315MB (315.0 W STC, 40.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PT IDN SOLAR TECH NUSA120H-315MB reaches 45.86 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 473 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (473 sq ft).
- 2026 tax credit baseline: cash residential installs of PT IDN SOLAR TECH NUSA120H-315MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PT IDN SOLAR TECH NUSA120H-315MB 8 kW Residential Fit
Needs 26 modules (473 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60315.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 293.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PT IDN SOLAR TECH NUSA120H-315MB by PT IDN SOLAR TECH grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for PT IDN SOLAR TECH NUSA120H-315MB?
Multiplying PT IDN SOLAR TECH NUSA120H-315MB's 9.95 A short-circuit current by 1.56 equals 15.52 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can PT IDN SOLAR TECH NUSA120H-315MB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 44.58 V cold Voc at 14 F and handles 9.95 A Isc; string inverters cap PT IDN SOLAR TECH NUSA120H-315MB at 13 panels on 600 V.
Is PT IDN SOLAR TECH NUSA120H-315MB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PT IDN SOLAR TECH NUSA120H-315MB rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)