Manufacturer: PT IDN SOLAR TECH Registry: CEC Verified Engineering Specification

PT IDN SOLAR TECH NUSA132H-505MT is a 505.0 W STC (476.0 W PTC) Mono-c-Si solar module ranking #4,444 of 21,677 CEC listings (top 20.8%; higher than 79.2% of peers). It delivers 21.31% efficiency, 45.69 V Voc at 25 C, and 50.26 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
505.0 W
PTC Wattage
476.0 W
Voc @ 25C
45.69 V
Efficiency
21.31%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PT IDN SOLAR TECH NUSA132H-505MT Compare Against Peer CEC Listings?

How PT IDN SOLAR TECH PT IDN SOLAR TECH NUSA132H-505MT handles rooftop heat (476.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PT IDN SOLAR TECH NUSA132H-505MT exhibits 13.98 A short-circuit current, requiring a 21.81 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #4,444 of 21,677 (95.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 37.9 m2 for an 8 kW system (20 panels for 10 kW). Mid-range 45.69 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does PT IDN SOLAR TECH NUSA132H-505MT Fall Across Listed CEC Models?

Where PT IDN SOLAR TECH NUSA132H-505MT (505.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PT IDN SOLAR TECH NUSA132H-505MT (505.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPT IDN SOLAR TECH : 505.0 W

What Dataset Percentiles Define PT IDN SOLAR TECH NUSA132H-505MT?

Percentile placement of PT IDN SOLAR TECH NUSA132H-505MT across power density (213.1 W/m2), thermal retention, and nameplate STC wattage.

PT IDN SOLAR TECH NUSA132H-505MT Engineering BenchmarksPercentile comparison of PT IDN SOLAR TECH NUSA132H-505MT wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage505.0 WPTC/STC Retention94.3%Module Efficiency21.31%

What Do the Dataset Ranks Show for PT IDN SOLAR TECH NUSA132H-505MT?

Four critical engineering numbers homeowners and solar installers check first when reviewing PT IDN SOLAR TECH NUSA132H-505MT specifications.

Rank #4,444 / 21,677

Top 20.8% STC Output

505.0 W STC (+120.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,088

21.31% Aperture Efficiency

Power density 213.1 W/m2 (1.40 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.26 V at -10 C (552.9 V string) and 51.57 V at -20 C (11 max).

8 kW Reference Array

16 Panels = 8,080 W STC

Occupies 37.9 m2 (408 sq ft) producing 7,616 W PTC; NEC 690.8 OCPD floor is 21.81 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.69 * (1 + (-0.286/100) * (-10 - 25)) = 50.26 V | OCPD = 1.56 * 13.98 = 21.81 A

Inputs from CEC Modules.csv for PT IDN SOLAR TECH NUSA132H-505MT: Voc=45.69 V, beta_Voc=-0.286%/C, Isc=13.98 A, STC=505.0 W, Area=2.37 m2.

Result: 11 panels max on 600 V (552.9 V); 16 panels for 8 kW (408 sq ft).

What Are the Published CEC Specifications for PT IDN SOLAR TECH NUSA132H-505MT?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PT IDN SOLAR TECH NUSA132H-505MT.

Official California Energy Commission (NREL SAM) test parameters for PT IDN SOLAR TECH NUSA132H-505MT.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 505.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 476.0 W (94.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.69 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.98 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.53 V / 13.11 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.286 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.31% (2.37 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many PT IDN SOLAR TECH NUSA132H-505MT Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PT IDN SOLAR TECH NUSA132H-505MT (505.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.06 kW 306 sq ft $1,517 $2,565
8 kW Class 16 8.08 kW 408 sq ft $2,022 $3,420
10 kW Class 20 10.1 kW 510 sq ft $2,528 $4,275

Which Sibling Wattage & Trim Variants Belong to This PT IDN SOLAR TECH Series?

All closely matched PT IDN SOLAR TECH wattages and cosmetic trims sharing the PT IDN SOLAR TECH NUSA132H-505MT architecture.

Sibling CEC listings grouped into the PT IDN SOLAR TECH NUSA132H-505MT wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PT IDN SOLAR TECH NUSA132H-500MT 500.0 W 471.2 W 45.55 V 38.38 V 21.1%
PT IDN SOLAR TECH NUSA132H-505MT 505.0 W 476.0 W 45.69 V 38.53 V 21.31%

How Many PT IDN SOLAR TECH NUSA132H-505MT Modules Fit in a Cold-Weather String?

Maximum series module counts for PT IDN SOLAR TECH NUSA132H-505MT from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.69V and beta_Voc=-0.286%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.57 V 11 panels 567.3 V 19 panels
-10 C (14 F) 50.26 V 11 panels 552.9 V 19 panels
0 C (32 F) 48.96 V 12 panels 587.5 V 20 panels
25 C (77 F STC) 45.69 V 13 panels 594.0 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to PT IDN SOLAR TECH NUSA132H-505MT?

Alternative CEC solar modules from competing brands near PT IDN SOLAR TECH NUSA132H-505MT (505.0 W), including Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505
Jiangsu Runergy New Energy Technology Co Ltd
505.0 W Tie (0 W) 45.72 V 29.88% 94.1%
Jiangsu Runergy New Energy Technology Co Ltd HY-WH132P8-505
Jiangsu Runergy New Energy Technology Co Ltd
505.0 W Tie (0 W) 45.72 V 29.88% 94.0%
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW505M
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD
505.0 W Tie (0 W) 45.16 V 26.58% 95.0%
Elin Energy (Sirius PV) ELNSM66M-HC-510
Elin Energy (Sirius PV)
510.0 W +5.0 W 46.05 V 21.61% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PT IDN SOLAR TECH NUSA132H-505MT?

Evaluate PT IDN SOLAR TECH NUSA132H-505MT (505.0 W STC, 45.69 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PT IDN SOLAR TECH NUSA132H-505MT reaches 51.57 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 16 panels for an 8 kW build require 408 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (408 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PT IDN SOLAR TECH NUSA132H-505MT carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PT IDN SOLAR TECH NUSA132H-505MT 8 kW Residential Fit

Needs 16 modules (408 sq ft) with a 25 A string OCPD, offsetting ~$2,022/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 476.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT IDN SOLAR TECH NUSA132H-505MT by PT IDN SOLAR TECH grounded in CEC test data and NEC 690.7/690.8 limits.

Why is PT IDN SOLAR TECH NUSA132H-505MT PTC wattage (476.0 W) lower than STC (505.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 476.0 W PTC (94.3% retention) across PT IDN SOLAR TECH NUSA132H-505MT's 2.37 m2 aperture.

Who should skip PT IDN SOLAR TECH NUSA132H-505MT on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 16 PT IDN SOLAR TECH NUSA132H-505MT panels (408 sq ft) leave unusable roof gaps vs. Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505.

What is the 1,000 V commercial string limit for PT IDN SOLAR TECH NUSA132H-505MT?

On 1,000 V commercial inverters at -10 C (50.26 V cold Voc), PT IDN SOLAR TECH NUSA132H-505MT fits up to 19 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.