Skip to main content
WireAndSun
Calculators
CEC PV Module

PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB — CEC Solar Module Specifications

Manufacturer: PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd Registry: CEC Verified Engineering Specification

PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB is a 400.0 W STC (371.0 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.51% efficiency, 36.94 V Voc at 25 C, and 40.69 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
400.0 W
PTC Wattage
371.0 W
Voc @ 25C
36.94 V
Efficiency
20.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB Compare Against Peer CEC Listings?

How PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB handles rooftop heat (371.0 W PTC), 8 kW sizing, and cold winter string voltage.

PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd builds the PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 205.1 W/m2 (0.60 percentage points above 19.91% CEC median). Compared against CertainTeed CTM10400HC11-08 (400.0 W), this model holds strong 92.8% PTC-to-STC heat retention (#10,898 of 21,677). Lower 36.94 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.56 A overcurrent floor served by a 25 A breaker.

Where Does PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB Fall Across Listed CEC Models?

Where PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB (400.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB (400.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPREMIER ENERGIES P: 400.0 W

What Dataset Percentiles Define PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB?

Percentile placement of PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB across power density (205.1 W/m2), thermal retention, and nameplate STC wattage.

PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB Engineering BenchmarksPercentile comparison of PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage400.0 WPTC/STC Retention92.8%Module Efficiency20.51%

What Do the Dataset Ranks Show for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB?

Four critical engineering numbers homeowners and solar installers check first when reviewing PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB specifications.

Rank #9,407 / 21,677

Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,487

20.51% Aperture Efficiency

Power density 205.1 W/m2 (0.60 percentage points above 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.69 V at -10 C (569.7 V string) and 41.76 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,000 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,420 W PTC; NEC 690.8 OCPD floor is 21.56 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.94 * (1 + (-0.29/100) * (-10 - 25)) = 40.69 V | OCPD = 1.56 * 13.82 = 21.56 A

Inputs from CEC Modules.csv for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB: Voc=36.94 V, beta_Voc=-0.29%/C, Isc=13.82 A, STC=400.0 W, Area=1.95 m2.

Result: 14 panels max on 600 V (569.7 V); 20 panels for 8 kW (420 sq ft).

What Are the Published CEC Specifications for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB.

Official California Energy Commission (NREL SAM) test parameters for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 400.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 371.0 W (92.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.94 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.82 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.13 V / 12.85 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.29 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.51% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB (400.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.0 kW 315 sq ft $1,502 $2,539
8 kW Class 20 8.0 kW 420 sq ft $2,002 $3,386
10 kW Class 25 10.0 kW 525 sq ft $2,503 $4,232

How Many PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB Modules Fit in a Cold-Weather String?

Maximum series module counts for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.94V and beta_Voc=-0.29%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.76 V 14 panels 584.6 V 23 panels
-10 C (14 F) 40.69 V 14 panels 569.7 V 24 panels
0 C (32 F) 39.62 V 15 panels 594.3 V 25 panels
25 C (77 F STC) 36.94 V 16 panels 591.0 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB?

Alternative CEC solar modules from competing brands near PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB (400.0 W), including CertainTeed CTM10400HC11-08.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CTM10400HC11-08
CertainTeed
400.0 W Tie (0 W) 37.08 V 20.73% 94.1%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
405.0 W +5.0 W 37.2 V 20.98% 93.4%
AXITEC AC-405MBT/108V
AXITEC
405.0 W +5.0 W 37.2 V 20.98% 93.4%
Aptos Solar Technology LLC DNA-108-BF10-405W
Aptos Solar Technology LLC
405.0 W +5.0 W 37.23 V 20.98% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB?

Evaluate PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB (400.0 W STC, 36.94 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB reaches 41.76 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CertainTeed CTM10400HC11-08.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 371.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB by PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB?

Multiplying PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB's 13.82 A short-circuit current by 1.56 equals 21.56 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.69 V cold Voc at 14 F and handles 13.82 A Isc; string inverters cap PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB at 14 panels on 600 V.

Is PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.