PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB — CEC Solar Module Specifications

Manufacturer: PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd Registry: CEC Verified Engineering Specification

PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB is a 555.0 W STC (518.1 W PTC) Mono-c-Si solar module ranking #2,550 of 21,677 CEC listings (top 12.6%; higher than 87.4% of peers). It delivers 21.68% efficiency, 49.88 V Voc at 25 C, and 54.73 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
555.0 W
PTC Wattage
518.1 W
Voc @ 25C
49.88 V
Efficiency
21.68%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB Compare Against Peer CEC Listings?

How PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB handles rooftop heat (518.1 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB exhibits 14.12 A short-circuit current, requiring a 22.03 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #2,550 of 21,677 (145.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 38.4 m2 for an 8 kW system (19 panels for 10 kW). Higher 49.88 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB Fall Across Listed CEC Models?

Where PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB (555.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB (555.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPREMIER ENERGIES P: 555.0 W

What Dataset Percentiles Define PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB?

Percentile placement of PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB across power density (216.8 W/m2), thermal retention, and nameplate STC wattage.

PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB Engineering BenchmarksPercentile comparison of PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage555.0 WPTC/STC Retention93.4%Module Efficiency21.68%

What Do the Dataset Ranks Show for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB?

Four critical engineering numbers homeowners and solar installers check first when reviewing PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB specifications.

Rank #2,550 / 21,677

Top 12.6% STC Output

555.0 W STC (+170.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,913

21.68% Aperture Efficiency

Power density 216.8 W/m2 (1.77 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.73 V at -10 C (547.3 V string) and 56.12 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,325 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,772 W PTC; NEC 690.8 OCPD floor is 22.03 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.88 * (1 + (-0.278/100) * (-10 - 25)) = 54.73 V | OCPD = 1.56 * 14.12 = 22.03 A

Inputs from CEC Modules.csv for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB: Voc=49.88 V, beta_Voc=-0.278%/C, Isc=14.12 A, STC=555.0 W, Area=2.56 m2.

Result: 10 panels max on 600 V (547.3 V); 15 panels for 8 kW (413 sq ft).

What Are the Published CEC Specifications for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB.

Official California Energy Commission (NREL SAM) test parameters for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 555.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 518.1 W (93.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.88 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.12 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.41 V / 13.4 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.278 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.68% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB (555.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.11 kW 303 sq ft $1,529 $2,586
8 kW Class 15 8.32 kW 413 sq ft $2,082 $3,521
10 kW Class 19 10.54 kW 524 sq ft $2,638 $4,461

Which Sibling Wattage & Trim Variants Belong to This PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd Series?

All closely matched PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd wattages and cosmetic trims sharing the PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB architecture.

Sibling CEC listings grouped into the PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-550HB 550.0 W 513.3 W 49.82 V 41.38 V 21.48%
PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB 555.0 W 518.1 W 49.88 V 41.41 V 21.68%

How Many PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB Modules Fit in a Cold-Weather String?

Maximum series module counts for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.88V and beta_Voc=-0.278%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.12 V 10 panels 561.2 V 17 panels
-10 C (14 F) 54.73 V 10 panels 547.3 V 18 panels
0 C (32 F) 53.35 V 11 panels 586.9 V 18 panels
25 C (77 F STC) 49.88 V 12 panels 598.6 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB?

Alternative CEC solar modules from competing brands near PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB (555.0 W), including CSI Solar Co Ltd CS6W-555MB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6W-555MB
CSI Solar Co Ltd
555.0 W Tie (0 W) 49.8 V 21.94% 94.2%
CSI Solar Co Ltd CS6W-555MB-AG
CSI Solar Co Ltd
555.0 W Tie (0 W) 49.8 V 22.2% 94.1%
Aptos Solar Technology LLC DNA-144-BF10-555W
Aptos Solar Technology LLC
555.0 W Tie (0 W) 50.0 V 21.51% 94.3%
AXITEC AC-555MBT/144V
AXITEC
555.0 W Tie (0 W) 50.05 V 21.68% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB?

Evaluate PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB (555.0 W STC, 49.88 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB reaches 56.12 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS6W-555MB.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 518.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB by PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB PTC wattage (518.1 W) lower than STC (555.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 518.1 W PTC (93.4% retention) across PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB's 2.56 m2 aperture.

Who should skip PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB panels (413 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS6W-555MB.

What is the 1,000 V commercial string limit for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB?

On 1,000 V commercial inverters at -10 C (54.73 V cold Voc), PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB fits up to 18 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.