PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB is a 555.0 W STC (515.0 W PTC) Mono-c-Si solar module ranking #2,550 of 21,677 CEC listings (top 12.6%; higher than 87.4% of peers). It delivers 21.68% efficiency, 49.88 V Voc at 25 C, and 54.86 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 555.0 W
- PTC Wattage
- 515.0 W
- Voc @ 25C
- 49.88 V
- Efficiency
- 21.68%
How Does PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB Compare Against Peer CEC Listings?
Engineering position of PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB (555.0 W STC) vs. CSI Solar Co Ltd CS6W-555MB across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB pairs strong 92.8% PTC-to-STC heat retention (#10,898 of 21,677) with 49.88 V nominal Voc. An 8 kW residential build (8,325 W DC, 7,725 W PTC) saves ~$2,082/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer CSI Solar Co Ltd CS6W-555MB offers a 555.0 W alternative.
Where Does PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB Fall Across Listed CEC Models?
Plots PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB at 555.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB?
Benchmarks PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB on STC wattage, thermal PTC/STC retention, and 21.68 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB by PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd.
Top 12.6% STC Output
555.0 W STC (+170.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.68% Aperture Efficiency
Power density 216.8 W/m2 (1.77 percentage points above 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.86 V at -10 C (548.6 V string) and 56.28 V at -20 C (10 max).
15 Panels = 8,325 W STC
Occupies 38.4 m2 (413 sq ft) producing 7,725 W PTC; NEC 690.8 OCPD floor is 22.03 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.88 * (1 + (-0.285/100) * (-10 - 25)) = 54.86 V | OCPD = 1.56 * 14.12 = 22.03 A
Inputs from CEC Modules.csv for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB: Voc=49.88 V, beta_Voc=-0.285%/C, Isc=14.12 A, STC=555.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (548.6 V); 15 panels for 8 kW (413 sq ft).
What Are the Published CEC Specifications for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB?
Laboratory test ratings recorded for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 555.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 515.0 W (92.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.88 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.12 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.41 V / 13.4 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.285 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.68% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (413 sq ft at 8 kW), and estimated Year-1 electric bill offset for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.11 kW | 303 sq ft | $1,529 | $2,586 |
| 8 kW Class | 15 | 8.32 kW | 413 sq ft | $2,082 | $3,521 |
| 10 kW Class | 19 | 10.54 kW | 524 sq ft | $2,638 | $4,461 |
Which Sibling Wattage & Trim Variants Belong to This PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd Series?
Sibling wattage bins and frame colors grouped with PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB under PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-550HGB | 550.0 W | 510.2 W | 49.82 V | 41.38 V | 21.48% |
| PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB | 555.0 W | 515.0 W | 49.88 V | 41.41 V | 21.68% |
| PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-560HGB | 560.0 W | 519.8 W | 49.91 V | 41.43 V | 21.88% |
How Many PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB (beta_Voc -0.285%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.28 V | 10 panels | 562.8 V | 17 panels |
| -10 C (14 F) | 54.86 V | 10 panels | 548.6 V | 18 panels |
| 0 C (32 F) | 53.43 V | 11 panels | 587.7 V | 18 panels |
| 25 C (77 F STC) | 49.88 V | 12 panels | 598.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB?
Closest cross-brand CEC competitors to PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB matched near 555.0 W STC and 49.88 V Voc, led by CSI Solar Co Ltd CS6W-555MB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6W-555MB CSI Solar Co Ltd |
555.0 W | Tie (0 W) | 49.8 V | 21.94% | 94.2% |
| CSI Solar Co Ltd CS6W-555MB-AG CSI Solar Co Ltd |
555.0 W | Tie (0 W) | 49.8 V | 22.2% | 94.1% |
| Aptos Solar Technology LLC DNA-144-BF10-555W Aptos Solar Technology LLC |
555.0 W | Tie (0 W) | 50.0 V | 21.51% | 94.3% |
| AXITEC AC-555MBT/144V AXITEC |
555.0 W | Tie (0 W) | 50.05 V | 21.68% | 93.6% |
What Are the Design Limits and Best-Fit Uses for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB?
Evaluate PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB (555.0 W STC, 49.88 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB reaches 56.28 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB 8 kW Residential Fit
Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS6W-555MB.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 515.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB by PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB?
Multiplying PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB's 14.12 A short-circuit current by 1.56 equals 22.03 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.86 V cold Voc at 14 F and handles 14.12 A Isc; string inverters cap PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB at 10 panels on 600 V.
Is PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB rely on utility bill offset (~$2,082/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)