ONYX SOLAR ENERGY SL ONYX G/G M06666 is a 291.0 W STC (256.6 W PTC) Mono-c-Si solar module ranking #17,252 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 14.62% efficiency, 42.0 V Voc at 25 C, and 46.85 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 291.0 W
- PTC Wattage
- 256.6 W
- Voc @ 25C
- 42.0 V
- Efficiency
- 14.62%
How Does ONYX SOLAR ENERGY SL ONYX G/G M06666 Compare Against Peer CEC Listings?
Engineering position of ONYX SOLAR ENERGY SL ONYX G/G M06666 (291.0 W STC) vs. Gintung Energy ASEC-285G6M6B across 5,889 CEC Mono-c-Si solar modules.
Built with 66 Mono-c-Si cells, ONYX SOLAR ENERGY SL ONYX G/G M06666 pairs typical 88.2% PTC-to-STC thermal output (256.6 W real-world rating) with 42.0 V nominal Voc. An 8 kW residential build (8,148 W DC, 7,185 W PTC) saves ~$2,040/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Gintung Energy ASEC-285G6M6B offers a 285.0 W alternative.
Where Does ONYX SOLAR ENERGY SL ONYX G/G M06666 Fall Across Listed CEC Models?
Plots ONYX SOLAR ENERGY SL ONYX G/G M06666 at 291.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define ONYX SOLAR ENERGY SL ONYX G/G M06666?
Benchmarks ONYX SOLAR ENERGY SL ONYX G/G M06666 on STC wattage, thermal PTC/STC retention, and 14.62 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for ONYX SOLAR ENERGY SL ONYX G/G M06666?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for ONYX SOLAR ENERGY SL ONYX G/G M06666 by ONYX SOLAR ENERGY SL.
291.0 W STC · Higher Than 20.4%
291.0 W STC (-94.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.62% Aperture Efficiency
Power density 146.2 W/m2 (5.29 percentage points below 19.91% CEC median). PTC/STC ratio: 88.2% (rank #21,309).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 46.85 V at -10 C (562.2 V string) and 48.24 V at -20 C (12 max).
28 Panels = 8,148 W STC
Occupies 55.7 m2 (600 sq ft) producing 7,185 W PTC; NEC 690.8 OCPD floor is 13.93 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 42.0 * (1 + (-0.33/100) * (-10 - 25)) = 46.85 V | OCPD = 1.56 * 8.93 = 13.93 A
Inputs from CEC Modules.csv for ONYX SOLAR ENERGY SL ONYX G/G M06666: Voc=42.0 V, beta_Voc=-0.33%/C, Isc=8.93 A, STC=291.0 W, Area=1.99 m2.
Result: 12 panels max on 600 V (562.2 V); 28 panels for 8 kW (600 sq ft).
What Are the Published CEC Specifications for ONYX SOLAR ENERGY SL ONYX G/G M06666?
Laboratory test ratings recorded for ONYX SOLAR ENERGY SL ONYX G/G M06666 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 291.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 256.6 W (88.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 42.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.93 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.0 V / 8.39 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.62% (1.99 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many ONYX SOLAR ENERGY SL ONYX G/G M06666 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (600 sq ft at 8 kW), and estimated Year-1 electric bill offset for ONYX SOLAR ENERGY SL ONYX G/G M06666.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.11 kW | 450 sq ft | $1,529 | $2,586 |
| 8 kW Class | 28 | 8.15 kW | 600 sq ft | $2,040 | $3,449 |
| 10 kW Class | 35 | 10.19 kW | 750 sq ft | $2,550 | $4,313 |
How Many ONYX SOLAR ENERGY SL ONYX G/G M06666 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for ONYX SOLAR ENERGY SL ONYX G/G M06666 (beta_Voc -0.33%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 48.24 V | 12 panels | 578.9 V | 20 panels |
| -10 C (14 F) | 46.85 V | 12 panels | 562.2 V | 21 panels |
| 0 C (32 F) | 45.47 V | 13 panels | 591.1 V | 21 panels |
| 25 C (77 F STC) | 42.0 V | 14 panels | 588.0 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to ONYX SOLAR ENERGY SL ONYX G/G M06666?
Closest cross-brand CEC competitors to ONYX SOLAR ENERGY SL ONYX G/G M06666 matched near 291.0 W STC and 42.0 V Voc, led by Gintung Energy ASEC-285G6M6B.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-285G6M6B Gintung Energy |
285.0 W | -6.0 W | 41.75 V | 16.07% | 88.1% |
| Gintung Energy GTEC-285G6M6B Gintung Energy |
285.0 W | -6.0 W | 41.75 V | 16.07% | 88.1% |
| Gintung Energy ASEC-285G6S6B Gintung Energy |
285.0 W | -6.0 W | 41.29 V | 16.07% | 87.7% |
| Gintung Energy GTEC-285G6S6B Gintung Energy |
285.0 W | -6.0 W | 41.29 V | 16.07% | 87.7% |
What Are the Design Limits and Best-Fit Uses for ONYX SOLAR ENERGY SL ONYX G/G M06666?
Evaluate ONYX SOLAR ENERGY SL ONYX G/G M06666 (291.0 W STC, 42.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), ONYX SOLAR ENERGY SL ONYX G/G M06666 reaches 48.24 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 600 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (600 sq ft).
- 2026 tax credit baseline: cash residential installs of ONYX SOLAR ENERGY SL ONYX G/G M06666 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
ONYX SOLAR ENERGY SL ONYX G/G M06666 8 kW Residential Fit
Needs 28 modules (600 sq ft) with a 15 A string OCPD, offsetting ~$2,040/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Gintung Energy ASEC-285G6M6B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 256.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for ONYX SOLAR ENERGY SL ONYX G/G M06666 by ONYX SOLAR ENERGY SL grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for ONYX SOLAR ENERGY SL ONYX G/G M06666?
Multiplying ONYX SOLAR ENERGY SL ONYX G/G M06666's 8.93 A short-circuit current by 1.56 equals 13.93 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can ONYX SOLAR ENERGY SL ONYX G/G M06666 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 46.85 V cold Voc at 14 F and handles 8.93 A Isc; string inverters cap ONYX SOLAR ENERGY SL ONYX G/G M06666 at 12 panels on 600 V.
Is ONYX SOLAR ENERGY SL ONYX G/G M06666 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of ONYX SOLAR ENERGY SL ONYX G/G M06666 rely on utility bill offset (~$2,040/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)