Gintung Energy ASEC-285G6S6B is a 285.0 W STC (250.0 W PTC) Mono-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 16.07% efficiency, 41.29 V Voc at 25 C, and 46.25 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 285.0 W
- PTC Wattage
- 250.0 W
- Voc @ 25C
- 41.29 V
- Efficiency
- 16.07%
How Does Gintung Energy ASEC-285G6S6B Compare Against Peer CEC Listings?
Engineering position of Gintung Energy ASEC-285G6S6B (285.0 W STC) vs. Ablytek 6MN6A285 across 5,889 CEC Mono-c-Si solar modules.
Ranking #17,598 across 21,677 CEC solar panels (below all-CEC median; higher than 17.3% of peers), Gintung Energy ASEC-285G6S6B operates as a compact residential or specialty off-grid module sitting 125.0 W below the 410.0 W Mono-c-Si median. Mid-range 41.29 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F. With typical 87.7% PTC-to-STC thermal output (250.0 W real-world rating), 29 panels occupy 553 sq ft and offset roughly $2,070/yr at average US rates (or $3,500/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Gintung Energy ASEC-285G6S6B Fall Across Listed CEC Models?
Plots Gintung Energy ASEC-285G6S6B at 285.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Gintung Energy ASEC-285G6S6B?
Benchmarks Gintung Energy ASEC-285G6S6B on STC wattage, thermal PTC/STC retention, and 16.07 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Gintung Energy ASEC-285G6S6B?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Gintung Energy ASEC-285G6S6B by Gintung Energy.
285.0 W STC · Higher Than 17.3%
285.0 W STC (-100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.07% Aperture Efficiency
Power density 160.7 W/m2 (3.84 percentage points below 19.91% CEC median). PTC/STC ratio: 87.7% (rank #21,496).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 46.25 V at -10 C (555.0 V string) and 47.66 V at -20 C (12 max).
29 Panels = 8,265 W STC
Occupies 51.4 m2 (553 sq ft) producing 7,250 W PTC; NEC 690.8 OCPD floor is 14.24 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.29 * (1 + (-0.343/100) * (-10 - 25)) = 46.25 V | OCPD = 1.56 * 9.13 = 14.24 A
Inputs from CEC Modules.csv for Gintung Energy ASEC-285G6S6B: Voc=41.29 V, beta_Voc=-0.343%/C, Isc=9.13 A, STC=285.0 W, Area=1.773 m2.
Result: 12 panels max on 600 V (555.0 V); 29 panels for 8 kW (553 sq ft).
What Are the Published CEC Specifications for Gintung Energy ASEC-285G6S6B?
Laboratory test ratings recorded for Gintung Energy ASEC-285G6S6B (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 285.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 250.0 W (87.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.29 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.13 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.95 V / 8.65 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.343 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.07% (1.773 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many Gintung Energy ASEC-285G6S6B Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (553 sq ft at 8 kW), and estimated Year-1 electric bill offset for Gintung Energy ASEC-285G6S6B.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.27 kW | 420 sq ft | $1,569 | $2,654 |
| 8 kW Class | 29 | 8.27 kW | 553 sq ft | $2,070 | $3,500 |
| 10 kW Class | 36 | 10.26 kW | 687 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?
Sibling wattage bins and frame colors grouped with Gintung Energy ASEC-285G6S6B under Gintung Energy to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Gintung Energy ASEC-275G6S6B | 275.0 W | 241.0 W | 41.06 V | 32.66 V | 15.51% |
| Gintung Energy ASEC-280G6S6B | 280.0 W | 245.5 W | 41.18 V | 32.83 V | 15.79% |
| Gintung Energy ASEC-285G6S6B | 285.0 W | 250.0 W | 41.29 V | 32.95 V | 16.07% |
| Gintung Energy ASEC-290G6S6B | 290.0 W | 254.6 W | 41.44 V | 33.03 V | 16.35% |
| Gintung Energy ASEC-295G6S6B | 295.0 W | 259.1 W | 41.54 V | 33.18 V | 16.64% |
How Many Gintung Energy ASEC-285G6S6B Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Gintung Energy ASEC-285G6S6B (beta_Voc -0.343%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 47.66 V | 12 panels | 571.9 V | 20 panels |
| -10 C (14 F) | 46.25 V | 12 panels | 555.0 V | 21 panels |
| 0 C (32 F) | 44.83 V | 13 panels | 582.8 V | 22 panels |
| 25 C (77 F STC) | 41.29 V | 14 panels | 578.1 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-285G6S6B?
Closest cross-brand CEC competitors to Gintung Energy ASEC-285G6S6B matched near 285.0 W STC and 41.29 V Voc, led by Ablytek 6MN6A285.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Ablytek 6MN6A285 Ablytek |
285.0 W | Tie (0 W) | 39.65 V | 17.52% | 89.8% |
| GermanSolar USA GSM6-60-285W GermanSolar USA |
285.0 W | Tie (0 W) | 39.65 V | 17.52% | 89.8% |
| Auxin Solar AXN6P610T285 Auxin Solar |
285.0 W | Tie (0 W) | 39.57 V | 17.52% | 90.4% |
| Anhui Rinengzhongtian Semiconductor Development QJP285-72 Anhui Rinengzhongtian Semiconductor Development |
285.0 W | Tie (0 W) | 43.1 V | 14.69% | 89.3% |
What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-285G6S6B?
Evaluate Gintung Energy ASEC-285G6S6B (285.0 W STC, 41.29 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-285G6S6B reaches 47.66 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 553 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (553 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-285G6S6B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintung Energy ASEC-285G6S6B 8 kW Residential Fit
Needs 29 modules (553 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Ablytek 6MN6A285.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 250.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintung Energy ASEC-285G6S6B by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.
How many Gintung Energy ASEC-285G6S6B panels fit on a 600 V winter solar string?
At -10 C (14 F), Gintung Energy ASEC-285G6S6B cold Voc rises from 41.29 V to 46.25 V (beta_Voc -0.343%/C), capping a 600 V string at 12 panels (555.0 V).
How much roof area does an 8 kW array of Gintung Energy ASEC-285G6S6B need?
An 8 kW DC system uses 29 Gintung Energy ASEC-285G6S6B modules (8,265 W STC / 7,250 W PTC), covering roughly 553 sq ft and saving ~$2,070/yr at 18.54 c/kWh.
How does Gintung Energy ASEC-285G6S6B compare against Ablytek 6MN6A285?
Gintung Energy ASEC-285G6S6B outputs 285.0 W STC (41.29 V Voc, rank #17,598 of 21,677), while Ablytek 6MN6A285 delivers 285.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.