Gintung Energy ASEC-285G6M6B is a 285.0 W STC (251.1 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 16.07% efficiency, 41.75 V Voc at 25 C, and 46.76 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 285.0 W
- PTC Wattage
- 251.1 W
- Voc @ 25C
- 41.75 V
- Efficiency
- 16.07%
How Does Gintung Energy ASEC-285G6M6B Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Gintung Energy ASEC-285G6M6B (Multi-c-Si) residential solar systems.
Homeowners evaluating Gintung Energy ASEC-285G6M6B need 22 panels for 6 kW or 29 panels (553 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (553 sq ft). Under NEC 690.7(A), beta_Voc (-0.343%/C) pushes open-circuit voltage to 46.76 V at 14 F and 48.19 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Gintung Energy ASEC-285G6M6B Fall Across Listed CEC Models?
Comparison of Gintung Energy ASEC-285G6M6B (285.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Dataset Percentiles Define Gintung Energy ASEC-285G6M6B?
Relative ranking of Gintung Energy ASEC-285G6M6B across nameplate watts, 88.1% PTC thermal ratio, and module aperture efficiency. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Do the Dataset Ranks Show for Gintung Energy ASEC-285G6M6B?
Summary of Gintung Energy ASEC-285G6M6B output rank, 8 kW array size (29 panels), efficiency rating, and 600 V string limit.
285.0 W STC · Higher Than 17.3%
285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.07% Aperture Efficiency
Power density 160.7 W/m2 (3.84 percentage points below 19.91% CEC median). PTC/STC ratio: 88.1% (rank #21,362).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 46.76 V at -10 C (561.1 V string) and 48.19 V at -20 C (12 max).
29 Panels = 8,265 W STC
Occupies 51.4 m2 (553 sq ft) producing 7,282 W PTC; NEC 690.8 OCPD floor is 14.09 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.75 * (1 + (-0.343/100) * (-10 - 25)) = 46.76 V | OCPD = 1.56 * 9.03 = 14.09 A
Inputs from CEC Modules.csv for Gintung Energy ASEC-285G6M6B: Voc=41.75 V, beta_Voc=-0.343%/C, Isc=9.03 A, STC=285.0 W, Area=1.773 m2.
Result: 12 panels max on 600 V (561.1 V); 29 panels for 8 kW (553 sq ft).
What Are the Published CEC Specifications for Gintung Energy ASEC-285G6M6B?
Complete CEC test sheet for Gintung Energy ASEC-285G6M6B including Isc (9.03 A), Voc (41.75 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 285.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 251.1 W (88.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.75 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.03 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.1 V / 8.61 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.343 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.07% (1.773 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Multi-c-Si) | Monofacial backsheet |
How Many Gintung Energy ASEC-285G6M6B Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Gintung Energy ASEC-285G6M6B.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.27 kW | 420 sq ft | $1,569 | $2,654 |
| 8 kW Class | 29 | 8.27 kW | 553 sq ft | $2,070 | $3,500 |
| 10 kW Class | 36 | 10.26 kW | 687 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?
Related Gintung Energy power steps and black/silver trims consolidated into this Gintung Energy ASEC-285G6M6B series guide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Gintung Energy ASEC-275G6M6B | 275.0 W | 242.0 W | 41.53 V | 32.82 V | 15.51% |
| Gintung Energy ASEC-280G6M6B | 280.0 W | 246.6 W | 41.64 V | 32.98 V | 15.79% |
| Gintung Energy ASEC-285G6M6B | 285.0 W | 251.1 W | 41.75 V | 33.1 V | 16.07% |
| Gintung Energy ASEC-290G6M6B | 290.0 W | 255.7 W | 41.89 V | 33.18 V | 16.35% |
| Gintung Energy ASEC-295G6M6B | 295.0 W | 260.2 W | 41.99 V | 33.33 V | 16.64% |
How Many Gintung Energy ASEC-285G6M6B Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Gintung Energy ASEC-285G6M6B (41.75 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 48.19 V | 12 panels | 578.3 V | 20 panels |
| -10 C (14 F) | 46.76 V | 12 panels | 561.1 V | 21 panels |
| 0 C (32 F) | 45.33 V | 13 panels | 589.3 V | 22 panels |
| 25 C (77 F STC) | 41.75 V | 14 panels | 584.5 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-285G6M6B?
Four comparable CEC modules such as Anhui Rinengzhongtian Semiconductor Development QJP285-72 (285.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Anhui Rinengzhongtian Semiconductor Development QJP285-72 Anhui Rinengzhongtian Semiconductor Development |
285.0 W | Tie (0 W) | 43.1 V | 14.69% | 89.3% |
| Ablytek 6MN6A285 Ablytek |
285.0 W | Tie (0 W) | 39.65 V | 17.52% | 89.8% |
| GermanSolar USA GSM6-60-285W GermanSolar USA |
285.0 W | Tie (0 W) | 39.65 V | 17.52% | 89.8% |
| Auxin Solar AXN6P610T285 Auxin Solar |
285.0 W | Tie (0 W) | 39.57 V | 17.52% | 90.4% |
What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-285G6M6B?
Evaluate Gintung Energy ASEC-285G6M6B (285.0 W STC, 41.75 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-285G6M6B reaches 48.19 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 553 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (553 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-285G6M6B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintung Energy ASEC-285G6M6B 8 kW Residential Fit
Needs 29 modules (553 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJP285-72.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 251.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintung Energy ASEC-285G6M6B by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Gintung Energy ASEC-285G6M6B PTC wattage (251.1 W) lower than STC (285.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 251.1 W PTC (88.1% retention) across Gintung Energy ASEC-285G6M6B's 1.773 m2 aperture.
Who should skip Gintung Energy ASEC-285G6M6B on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 29 Gintung Energy ASEC-285G6M6B panels (553 sq ft) leave unusable roof gaps vs. Anhui Rinengzhongtian Semiconductor Development QJP285-72.
What is the 1,000 V commercial string limit for Gintung Energy ASEC-285G6M6B?
On 1,000 V commercial inverters at -10 C (46.76 V cold Voc), Gintung Energy ASEC-285G6M6B fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy ASEC-285G6M6B.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)