Gintung Energy GTEC-285G6S6B — CEC Solar Module Specifications

Manufacturer: Gintung Energy Registry: CEC Verified Engineering Specification

Gintung Energy GTEC-285G6S6B is a 285.0 W STC (250.0 W PTC) Mono-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 16.07% efficiency, 41.29 V Voc at 25 C, and 46.25 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
285.0 W
PTC Wattage
250.0 W
Voc @ 25C
41.29 V
Efficiency
16.07%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Gintung Energy GTEC-285G6S6B Compare Against Peer CEC Listings?

Solar engineering breakdown for Gintung Energy GTEC-285G6S6B: PTC thermal retention, roof footprint, and cold Voc string bounds. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Across 5,889 Mono-c-Si listings from Gintung Energy and peers, Gintung Energy GTEC-285G6S6B stands 125.0 W below the 410.0 W Mono-c-Si median and typical 87.7% PTC-to-STC thermal output (250.0 W real-world rating). Sizing 6 kW (22 panels) to 10 kW (36 panels) yields $1,569-$2,568/yr in baseline US bill offset. Mid-range 41.29 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Gintung Energy GTEC-285G6S6B Fall Across Listed CEC Models?

Distribution marker showing Gintung Energy GTEC-285G6S6B (285.0 W) relative to the 385.0 W all-CEC solar panel median. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Gintung Energy GTEC-285G6S6B (285.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGintung Energy GTE: 285.0 W

What Dataset Percentiles Define Gintung Energy GTEC-285G6S6B?

Dataset percentiles tracking Gintung Energy GTEC-285G6S6B power output, thermal retention ratio, and aperture efficiency against 21,677 models. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Gintung Energy GTEC-285G6S6B Engineering BenchmarksPercentile comparison of Gintung Energy GTEC-285G6S6B wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage285.0 WPTC/STC Retention87.7%Module Efficiency16.07%

What Do the Dataset Ranks Show for Gintung Energy GTEC-285G6S6B?

Benchmark highlights for Gintung Energy GTEC-285G6S6B covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #17,598 / 21,677

285.0 W STC · Higher Than 17.3%

285.0 W STC (-100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,013

16.07% Aperture Efficiency

Power density 160.7 W/m2 (3.84 percentage points below 19.91% CEC median). PTC/STC ratio: 87.7% (rank #21,496).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 46.25 V at -10 C (555.0 V string) and 47.66 V at -20 C (12 max).

8 kW Reference Array

29 Panels = 8,265 W STC

Occupies 51.4 m2 (553 sq ft) producing 7,250 W PTC; NEC 690.8 OCPD floor is 14.24 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.29 * (1 + (-0.343/100) * (-10 - 25)) = 46.25 V | OCPD = 1.56 * 9.13 = 14.24 A

Inputs from CEC Modules.csv for Gintung Energy GTEC-285G6S6B: Voc=41.29 V, beta_Voc=-0.343%/C, Isc=9.13 A, STC=285.0 W, Area=1.773 m2.

Result: 12 panels max on 600 V (555.0 V); 29 panels for 8 kW (553 sq ft).

What Are the Published CEC Specifications for Gintung Energy GTEC-285G6S6B?

Official CEC datasheet figures for Gintung Energy GTEC-285G6S6B (Mono-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy GTEC-285G6S6B.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 285.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 250.0 W (87.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.29 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.13 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.95 V / 8.65 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.343 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.07% (1.773 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many Gintung Energy GTEC-285G6S6B Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Gintung Energy GTEC-285G6S6B modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.27 kW 420 sq ft $1,569 $2,654
8 kW Class 29 8.27 kW 553 sq ft $2,070 $3,500
10 kW Class 36 10.26 kW 687 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

Consolidated Gintung Energy wattage variants sharing the Gintung Energy GTEC-285G6S6B mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the Gintung Energy GTEC-285G6S6B wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Gintung Energy GTEC-275G6S6B 275.0 W 241.0 W 41.06 V 32.66 V 15.51%
Gintung Energy GTEC-280G6S6B 280.0 W 245.5 W 41.18 V 32.83 V 15.79%
Gintung Energy GTEC-285G6S6B 285.0 W 250.0 W 41.29 V 32.95 V 16.07%
Gintung Energy GTEC-290G6S6B 290.0 W 254.6 W 41.44 V 33.03 V 16.35%
Gintung Energy GTEC-295G6S6B 295.0 W 259.1 W 41.54 V 33.18 V 16.64%

How Many Gintung Energy GTEC-285G6S6B Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Gintung Energy GTEC-285G6S6B (46.25 V at 14 F).

Computed from Voc=41.29V and beta_Voc=-0.343%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 47.66 V 12 panels 571.9 V 20 panels
-10 C (14 F) 46.25 V 12 panels 555.0 V 21 panels
0 C (32 F) 44.83 V 13 panels 582.8 V 22 panels
25 C (77 F STC) 41.29 V 14 panels 578.1 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-285G6S6B?

Competing CEC solar panels closest to Gintung Energy GTEC-285G6S6B in nameplate wattage and Voc, starting with Ablytek 6MN6A285.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Ablytek 6MN6A285
Ablytek
285.0 W Tie (0 W) 39.65 V 17.52% 89.8%
GermanSolar USA GSM6-60-285W
GermanSolar USA
285.0 W Tie (0 W) 39.65 V 17.52% 89.8%
Auxin Solar AXN6P610T285
Auxin Solar
285.0 W Tie (0 W) 39.57 V 17.52% 90.4%
Anhui Rinengzhongtian Semiconductor Development QJP285-72
Anhui Rinengzhongtian Semiconductor Development
285.0 W Tie (0 W) 43.1 V 14.69% 89.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-285G6S6B?

Evaluate Gintung Energy GTEC-285G6S6B (285.0 W STC, 41.29 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-285G6S6B reaches 47.66 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 553 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (553 sq ft).
  • 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-285G6S6B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Gintung Energy GTEC-285G6S6B 8 kW Residential Fit

Needs 29 modules (553 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Ablytek 6MN6A285.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 250.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy GTEC-285G6S6B by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Gintung Energy GTEC-285G6S6B?

Multiplying Gintung Energy GTEC-285G6S6B's 9.13 A short-circuit current by 1.56 equals 14.24 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Gintung Energy GTEC-285G6S6B pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 46.25 V cold Voc at 14 F and handles 9.13 A Isc; string inverters cap Gintung Energy GTEC-285G6S6B at 12 panels on 600 V.

Is Gintung Energy GTEC-285G6S6B eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Gintung Energy GTEC-285G6S6B rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.