Mitsubishi Electric PV-UJ220GA6 is a 220.0 W STC (198.6 W PTC) Multi-c-Si solar module ranking #20,759 of 21,677 CEC listings (below all-CEC median; higher than 3.8% of peers). It delivers 13.35% efficiency, 36.2 V Voc at 25 C, and 40.25 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 220.0 W
- PTC Wattage
- 198.6 W
- Voc @ 25C
- 36.2 V
- Efficiency
- 13.35%
How Does Mitsubishi Electric PV-UJ220GA6 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Mitsubishi Electric PV-UJ220GA6 (Multi-c-Si) residential solar systems.
Homeowners evaluating Mitsubishi Electric PV-UJ220GA6 need 28 panels for 6 kW or 37 panels (656 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (656 sq ft). Under NEC 690.7(A), beta_Voc (-0.32%/C) pushes open-circuit voltage to 40.25 V at 14 F and 41.41 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Mitsubishi Electric PV-UJ220GA6 Fall Across Listed CEC Models?
Comparison of Mitsubishi Electric PV-UJ220GA6 (220.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define Mitsubishi Electric PV-UJ220GA6?
Relative ranking of Mitsubishi Electric PV-UJ220GA6 across nameplate watts, 90.3% PTC thermal ratio, and module aperture efficiency. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What Do the Dataset Ranks Show for Mitsubishi Electric PV-UJ220GA6?
Summary of Mitsubishi Electric PV-UJ220GA6 output rank, 8 kW array size (37 panels), efficiency rating, and 600 V string limit.
220.0 W STC · Higher Than 3.8%
220.0 W STC (-165.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.35% Aperture Efficiency
Power density 133.5 W/m2 (6.56 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.25 V at -10 C (563.5 V string) and 41.41 V at -20 C (14 max).
37 Panels = 8,140 W STC
Occupies 61.0 m2 (656 sq ft) producing 7,348 W PTC; NEC 690.8 OCPD floor is 12.79 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.2 * (1 + (-0.32/100) * (-10 - 25)) = 40.25 V | OCPD = 1.56 * 8.2 = 12.79 A
Inputs from CEC Modules.csv for Mitsubishi Electric PV-UJ220GA6: Voc=36.2 V, beta_Voc=-0.32%/C, Isc=8.2 A, STC=220.0 W, Area=1.648 m2.
Result: 14 panels max on 600 V (563.5 V); 37 panels for 8 kW (656 sq ft).
What Are the Published CEC Specifications for Mitsubishi Electric PV-UJ220GA6?
Complete CEC test sheet for Mitsubishi Electric PV-UJ220GA6 including Isc (8.2 A), Voc (36.2 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 220.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 198.6 W (90.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.7 V / 7.39 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.32 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.35% (1.648 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Mitsubishi Electric PV-UJ220GA6 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Mitsubishi Electric PV-UJ220GA6.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 28 | 6.16 kW | 497 sq ft | $1,542 | $2,607 |
| 8 kW Class | 37 | 8.14 kW | 656 sq ft | $2,037 | $3,445 |
| 10 kW Class | 46 | 10.12 kW | 816 sq ft | $2,533 | $4,283 |
How Many Mitsubishi Electric PV-UJ220GA6 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Mitsubishi Electric PV-UJ220GA6 (36.2 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.41 V | 14 panels | 579.7 V | 24 panels |
| -10 C (14 F) | 40.25 V | 14 panels | 563.5 V | 24 panels |
| 0 C (32 F) | 39.1 V | 15 panels | 586.5 V | 25 panels |
| 25 C (77 F STC) | 36.2 V | 16 panels | 579.2 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Mitsubishi Electric PV-UJ220GA6?
Four comparable CEC modules such as Centrosolar America DP60 220 (220.0 W) for side-by-side solar quote checks. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DP60 220 Centrosolar America |
220.0 W | Tie (0 W) | 36.26 V | 13.42% | 89.8% |
| Anhui Rinengzhongtian Semiconductor Development QJM220-60 Anhui Rinengzhongtian Semiconductor Development |
220.0 W | Tie (0 W) | 36.29 V | 13.52% | 89.8% |
| Alps Technology ATI-M660-220 Alps Technology |
220.0 W | Tie (0 W) | 36.06 V | 13.67% | 86.0% |
| Anji Technology AJP-M660-220 Anji Technology |
220.0 W | Tie (0 W) | 36.06 V | 13.55% | 86.0% |
What Are the Design Limits and Best-Fit Uses for Mitsubishi Electric PV-UJ220GA6?
Evaluate Mitsubishi Electric PV-UJ220GA6 (220.0 W STC, 36.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Mitsubishi Electric PV-UJ220GA6 reaches 41.41 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 37 panels for an 8 kW build require 656 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (656 sq ft).
- 2026 tax credit baseline: cash residential installs of Mitsubishi Electric PV-UJ220GA6 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Mitsubishi Electric PV-UJ220GA6 8 kW Residential Fit
Needs 37 modules (656 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Centrosolar America DP60 220.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 198.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Mitsubishi Electric PV-UJ220GA6 by Mitsubishi Electric grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Mitsubishi Electric PV-UJ220GA6 PTC wattage (198.6 W) lower than STC (220.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 198.6 W PTC (90.3% retention) across Mitsubishi Electric PV-UJ220GA6's 1.648 m2 aperture.
Who should skip Mitsubishi Electric PV-UJ220GA6 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 37 Mitsubishi Electric PV-UJ220GA6 panels (656 sq ft) leave unusable roof gaps vs. Centrosolar America DP60 220.
What is the 1,000 V commercial string limit for Mitsubishi Electric PV-UJ220GA6?
On 1,000 V commercial inverters at -10 C (40.25 V cold Voc), Mitsubishi Electric PV-UJ220GA6 fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Mitsubishi Electric PV-UJ220GA6.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)