Skip to main content
WireAndSun
Calculators
CEC PV Module

Mitsubishi Electric PV-UJ220GA6-D — CEC Solar Module Specifications

Manufacturer: Mitsubishi Electric Registry: CEC Verified Engineering Specification

Mitsubishi Electric PV-UJ220GA6-D is a 220.0 W STC (198.6 W PTC) Multi-c-Si solar module ranking #20,759 of 21,677 CEC listings (below all-CEC median; higher than 3.8% of peers). It delivers 13.35% efficiency, 36.2 V Voc at 25 C, and 40.25 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
220.0 W
PTC Wattage
198.6 W
Voc @ 25C
36.2 V
Efficiency
13.35%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mitsubishi Electric PV-UJ220GA6-D Compare Against Peer CEC Listings?

Solar engineering breakdown for Mitsubishi Electric PV-UJ220GA6-D: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Measured at 220.0 W STC and 198.6 W PTC, Mitsubishi Electric PV-UJ220GA6-D sits -165.0 W vs all-CEC median (below all-CEC median; higher than 3.8% of peers) among 21,677 listed modules. Power density reaches 133.5 W/m2 (6.56 percentage points below 19.91% CEC median). Lower 36.2 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer Centrosolar America DP60 220 rates 220.0 W.

Where Does Mitsubishi Electric PV-UJ220GA6-D Fall Across Listed CEC Models?

Distribution marker showing Mitsubishi Electric PV-UJ220GA6-D (220.0 W) relative to the 385.0 W all-CEC solar panel median. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mitsubishi Electric PV-UJ220GA6-D (220.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMitsubishi Electri: 220.0 W

What Dataset Percentiles Define Mitsubishi Electric PV-UJ220GA6-D?

Dataset percentiles tracking Mitsubishi Electric PV-UJ220GA6-D power output, thermal retention ratio, and aperture efficiency against 21,677 models. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Mitsubishi Electric PV-UJ220GA6-D Engineering BenchmarksPercentile comparison of Mitsubishi Electric PV-UJ220GA6-D wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage220.0 WPTC/STC Retention90.3%Module Efficiency13.35%

What Do the Dataset Ranks Show for Mitsubishi Electric PV-UJ220GA6-D?

Benchmark highlights for Mitsubishi Electric PV-UJ220GA6-D covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #20,759 / 21,677

220.0 W STC · Higher Than 3.8%

220.0 W STC (-165.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,285

13.35% Aperture Efficiency

Power density 133.5 W/m2 (6.56 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.25 V at -10 C (563.5 V string) and 41.41 V at -20 C (14 max).

8 kW Reference Array

37 Panels = 8,140 W STC

Occupies 61.0 m2 (656 sq ft) producing 7,348 W PTC; NEC 690.8 OCPD floor is 12.79 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.2 * (1 + (-0.32/100) * (-10 - 25)) = 40.25 V | OCPD = 1.56 * 8.2 = 12.79 A

Inputs from CEC Modules.csv for Mitsubishi Electric PV-UJ220GA6-D: Voc=36.2 V, beta_Voc=-0.32%/C, Isc=8.2 A, STC=220.0 W, Area=1.648 m2.

Result: 14 panels max on 600 V (563.5 V); 37 panels for 8 kW (656 sq ft).

What Are the Published CEC Specifications for Mitsubishi Electric PV-UJ220GA6-D?

Official CEC datasheet figures for Mitsubishi Electric PV-UJ220GA6-D (Multi-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for Mitsubishi Electric PV-UJ220GA6-D.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 220.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 198.6 W (90.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.2 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.7 V / 7.39 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.32 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.35% (1.648 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Mitsubishi Electric PV-UJ220GA6-D Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Mitsubishi Electric PV-UJ220GA6-D modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 28 6.16 kW 497 sq ft $1,542 $2,607
8 kW Class 37 8.14 kW 656 sq ft $2,037 $3,445
10 kW Class 46 10.12 kW 816 sq ft $2,533 $4,283

How Many Mitsubishi Electric PV-UJ220GA6-D Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Mitsubishi Electric PV-UJ220GA6-D (40.25 V at 14 F).

Computed from Voc=36.2V and beta_Voc=-0.32%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.41 V 14 panels 579.7 V 24 panels
-10 C (14 F) 40.25 V 14 panels 563.5 V 24 panels
0 C (32 F) 39.1 V 15 panels 586.5 V 25 panels
25 C (77 F STC) 36.2 V 16 panels 579.2 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Mitsubishi Electric PV-UJ220GA6-D?

Competing CEC solar panels closest to Mitsubishi Electric PV-UJ220GA6-D in nameplate wattage and Voc, starting with Centrosolar America DP60 220.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DP60 220
Centrosolar America
220.0 W Tie (0 W) 36.26 V 13.42% 89.8%
Anhui Rinengzhongtian Semiconductor Development QJM220-60
Anhui Rinengzhongtian Semiconductor Development
220.0 W Tie (0 W) 36.29 V 13.52% 89.8%
Alps Technology ATI-M660-220
Alps Technology
220.0 W Tie (0 W) 36.06 V 13.67% 86.0%
Anji Technology AJP-M660-220
Anji Technology
220.0 W Tie (0 W) 36.06 V 13.55% 86.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mitsubishi Electric PV-UJ220GA6-D?

Evaluate Mitsubishi Electric PV-UJ220GA6-D (220.0 W STC, 36.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mitsubishi Electric PV-UJ220GA6-D reaches 41.41 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 37 panels for an 8 kW build require 656 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (656 sq ft).
  • 2026 tax credit baseline: cash residential installs of Mitsubishi Electric PV-UJ220GA6-D carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mitsubishi Electric PV-UJ220GA6-D 8 kW Residential Fit

Needs 37 modules (656 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Centrosolar America DP60 220.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 198.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mitsubishi Electric PV-UJ220GA6-D by Mitsubishi Electric grounded in CEC test data and NEC 690.7/690.8 limits.

How many Mitsubishi Electric PV-UJ220GA6-D panels fit on a 600 V winter solar string?

At -10 C (14 F), Mitsubishi Electric PV-UJ220GA6-D cold Voc rises from 36.2 V to 40.25 V (beta_Voc -0.32%/C), capping a 600 V string at 14 panels (563.5 V).

How much roof area does an 8 kW array of Mitsubishi Electric PV-UJ220GA6-D need?

An 8 kW DC system uses 37 Mitsubishi Electric PV-UJ220GA6-D modules (8,140 W STC / 7,348 W PTC), covering roughly 656 sq ft and saving ~$2,037/yr at 18.54 c/kWh.

How does Mitsubishi Electric PV-UJ220GA6-D compare against Centrosolar America DP60 220?

Mitsubishi Electric PV-UJ220GA6-D outputs 220.0 W STC (36.2 V Voc, rank #20,759 of 21,677), while Centrosolar America DP60 220 delivers 220.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.