Skip to main content
WireAndSun
Calculators
CEC PV Module

Mitsubishi Electric PV-UD185MF5 — CEC Solar Module Specifications

Manufacturer: Mitsubishi Electric Registry: CEC Verified Engineering Specification

Mitsubishi Electric PV-UD185MF5 is a 185.0 W STC (166.2 W PTC) Multi-c-Si solar module ranking #21,185 of 21,677 CEC listings (below all-CEC median; higher than 2.1% of peers). It delivers 13.38% efficiency, 30.6 V Voc at 25 C, and 34.27 V cold Voc at -10 C (17 panels max per 600 V string).

STC Wattage
185.0 W
PTC Wattage
166.2 W
Voc @ 25C
30.6 V
Efficiency
13.38%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mitsubishi Electric PV-UD185MF5 Compare Against Peer CEC Listings?

Engineering position of Mitsubishi Electric PV-UD185MF5 (185.0 W STC) vs. Lightway Green New Energy LW185(23)P1310x990 across 1,407 CEC Multi-c-Si solar modules.

Ranking #21,185 across 21,677 CEC solar panels (below all-CEC median; higher than 2.1% of peers), Mitsubishi Electric PV-UD185MF5 operates as a compact residential or specialty off-grid module sitting 93.8 W below the 278.8 W Multi-c-Si median. Lower 30.6 V string voltage fits 17 panels in series at 14 F and pairs easily with microinverters. With typical 89.8% PTC-to-STC thermal output (166.2 W real-world rating), 44 panels occupy 655 sq ft and offset roughly $2,037/yr at average US rates (or $3,445/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Mitsubishi Electric PV-UD185MF5 Fall Across Listed CEC Models?

Plots Mitsubishi Electric PV-UD185MF5 at 185.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mitsubishi Electric PV-UD185MF5 (185.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMitsubishi Electri: 185.0 W

What Dataset Percentiles Define Mitsubishi Electric PV-UD185MF5?

Benchmarks Mitsubishi Electric PV-UD185MF5 on STC wattage, thermal PTC/STC retention, and 13.38 aperture conversion efficiency against CEC peers.

Mitsubishi Electric PV-UD185MF5 Engineering BenchmarksPercentile comparison of Mitsubishi Electric PV-UD185MF5 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage185.0 WPTC/STC Retention89.8%Module Efficiency13.38%

What Do the Dataset Ranks Show for Mitsubishi Electric PV-UD185MF5?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Mitsubishi Electric PV-UD185MF5 by Mitsubishi Electric.

Rank #21,185 / 21,677

185.0 W STC · Higher Than 2.1%

185.0 W STC (-200.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,271

13.38% Aperture Efficiency

Power density 133.8 W/m2 (6.53 percentage points below 19.91% CEC median). PTC/STC ratio: 89.8% (rank #19,481).

NEC 690.7 Limit

17 Panels Max @ -10 C (600 V)

Cold Voc reaches 34.27 V at -10 C (582.6 V string) and 35.32 V at -20 C (16 max).

8 kW Reference Array

44 Panels = 8,140 W STC

Occupies 60.9 m2 (655 sq ft) producing 7,313 W PTC; NEC 690.8 OCPD floor is 12.68 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 30.6 * (1 + (-0.343/100) * (-10 - 25)) = 34.27 V | OCPD = 1.56 * 8.13 = 12.68 A

Inputs from CEC Modules.csv for Mitsubishi Electric PV-UD185MF5: Voc=30.6 V, beta_Voc=-0.343%/C, Isc=8.13 A, STC=185.0 W, Area=1.383 m2.

Result: 17 panels max on 600 V (582.6 V); 44 panels for 8 kW (655 sq ft).

What Are the Published CEC Specifications for Mitsubishi Electric PV-UD185MF5?

Laboratory test ratings recorded for Mitsubishi Electric PV-UD185MF5 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Mitsubishi Electric PV-UD185MF5.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 185.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 166.2 W (89.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 30.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.13 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 24.4 V / 7.58 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.343 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.38% (1.383 m2) Array roof footprint density
Cell Count & Technology 50 cells (Multi-c-Si) Monofacial backsheet

How Many Mitsubishi Electric PV-UD185MF5 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (655 sq ft at 8 kW), and estimated Year-1 electric bill offset for Mitsubishi Electric PV-UD185MF5.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 33 6.11 kW 491 sq ft $1,529 $2,586
8 kW Class 44 8.14 kW 655 sq ft $2,037 $3,445
10 kW Class 55 10.18 kW 819 sq ft $2,548 $4,308

Which Sibling Wattage & Trim Variants Belong to This Mitsubishi Electric Series?

Sibling wattage bins and frame colors grouped with Mitsubishi Electric PV-UD185MF5 under Mitsubishi Electric to prevent duplicate spec pages.

Sibling CEC listings grouped into the Mitsubishi Electric PV-UD185MF5 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Mitsubishi Electric PV-UD175MF5 175.0 W 157.0 W 30.2 V 23.9 V 12.66%
Mitsubishi Electric PV-UD180MF5 180.0 W 161.6 W 30.4 V 24.2 V 13.02%
Mitsubishi Electric PV-UD185MF5 185.0 W 166.2 W 30.6 V 24.4 V 13.38%
Mitsubishi Electric PV-UD190MF5 190.0 W 169.8 W 30.8 V 24.7 V 13.72%

How Many Mitsubishi Electric PV-UD185MF5 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Mitsubishi Electric PV-UD185MF5 (beta_Voc -0.343%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=30.6V and beta_Voc=-0.343%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 35.32 V 16 panels 565.1 V 28 panels
-10 C (14 F) 34.27 V 17 panels 582.6 V 29 panels
0 C (32 F) 33.22 V 18 panels 598.0 V 30 panels
25 C (77 F STC) 30.6 V 19 panels 581.4 V 32 panels

Which Cross-Brand Solar Modules Compare Closest to Mitsubishi Electric PV-UD185MF5?

Closest cross-brand CEC competitors to Mitsubishi Electric PV-UD185MF5 matched near 185.0 W STC and 30.6 V Voc, led by Lightway Green New Energy LW185(23)P1310x990.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Lightway Green New Energy LW185(23)P1310x990
Lightway Green New Energy
185.0 W Tie (0 W) 30.0 V 14.41% 89.6%
APOS Energy AS185
APOS Energy
185.0 W Tie (0 W) 29.78 V 13.8% 89.6%
Centrosolar America DP48 185
Centrosolar America
185.0 W Tie (0 W) 29.49 V 13.96% 88.4%
Solartech Energy ASC-6P-48-185
Solartech Energy
185.0 W Tie (0 W) 29.49 V 13.96% 88.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mitsubishi Electric PV-UD185MF5?

Evaluate Mitsubishi Electric PV-UD185MF5 (185.0 W STC, 30.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mitsubishi Electric PV-UD185MF5 reaches 35.32 V per panel—exceeding 16 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 44 panels for an 8 kW build require 655 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 44 panels (655 sq ft).
  • 2026 tax credit baseline: cash residential installs of Mitsubishi Electric PV-UD185MF5 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mitsubishi Electric PV-UD185MF5 8 kW Residential Fit

Needs 44 modules (655 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 17 panels (-10 C) or 16 panels (-20 C), or compare Lightway Green New Energy LW185(23)P1310x990.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 166.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mitsubishi Electric PV-UD185MF5 by Mitsubishi Electric grounded in CEC test data and NEC 690.7/690.8 limits.

How many Mitsubishi Electric PV-UD185MF5 panels fit on a 600 V winter solar string?

At -10 C (14 F), Mitsubishi Electric PV-UD185MF5 cold Voc rises from 30.6 V to 34.27 V (beta_Voc -0.343%/C), capping a 600 V string at 17 panels (582.6 V).

How much roof area does an 8 kW array of Mitsubishi Electric PV-UD185MF5 need?

An 8 kW DC system uses 44 Mitsubishi Electric PV-UD185MF5 modules (8,140 W STC / 7,313 W PTC), covering roughly 655 sq ft and saving ~$2,037/yr at 18.54 c/kWh.

How does Mitsubishi Electric PV-UD185MF5 compare against Lightway Green New Energy LW185(23)P1310x990?

Mitsubishi Electric PV-UD185MF5 outputs 185.0 W STC (30.6 V Voc, rank #21,185 of 21,677), while Lightway Green New Energy LW185(23)P1310x990 delivers 185.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.