Mitrex M335-RF041F is a 335.0 W STC (305.1 W PTC) Mono-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 16.75% efficiency, 48.8 V Voc at 25 C, and 53.45 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 335.0 W
- PTC Wattage
- 305.1 W
- Voc @ 25C
- 48.8 V
- Efficiency
- 16.75%
How Does Mitrex M335-RF041F Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Mitrex M335-RF041F (Mono-c-Si) residential solar systems. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
Mitrex M335-RF041F delivers 167.5 W/m2 (3.16 percentage points below 19.91% CEC median) and typical 91.1% PTC-to-STC thermal output (305.1 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (517 sq ft). At -4 F (-20 C), string voltage climbs to 54.77 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with DEHUI SOLAR POWER INC DH-72P-335W (335.0 W).
Where Does Mitrex M335-RF041F Fall Across Listed CEC Models?
Comparison of Mitrex M335-RF041F (335.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Dataset Percentiles Define Mitrex M335-RF041F?
Relative ranking of Mitrex M335-RF041F across nameplate watts, 91.1% PTC thermal ratio, and module aperture efficiency. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Do the Dataset Ranks Show for Mitrex M335-RF041F?
Summary of Mitrex M335-RF041F output rank, 8 kW array size (24 panels), efficiency rating, and 600 V string limit.
335.0 W STC · Higher Than 34.7%
335.0 W STC (-50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.75% Aperture Efficiency
Power density 167.5 W/m2 (3.16 percentage points below 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.45 V at -10 C (588.0 V string) and 54.77 V at -20 C (10 max).
24 Panels = 8,040 W STC
Occupies 48.0 m2 (517 sq ft) producing 7,322 W PTC; NEC 690.8 OCPD floor is 13.54 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.8 * (1 + (-0.272/100) * (-10 - 25)) = 53.45 V | OCPD = 1.56 * 8.68 = 13.54 A
Inputs from CEC Modules.csv for Mitrex M335-RF041F: Voc=48.8 V, beta_Voc=-0.272%/C, Isc=8.68 A, STC=335.0 W, Area=2.0 m2.
Result: 11 panels max on 600 V (588.0 V); 24 panels for 8 kW (517 sq ft).
What Are the Published CEC Specifications for Mitrex M335-RF041F?
Complete CEC test sheet for Mitrex M335-RF041F including Isc (8.68 A), Voc (48.8 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 335.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 305.1 W (91.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.68 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.9 V / 8.19 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.272 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.75% (2.0 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Mitrex M335-RF041F Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Mitrex M335-RF041F.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.03 kW | 388 sq ft | $1,509 | $2,552 |
| 8 kW Class | 24 | 8.04 kW | 517 sq ft | $2,012 | $3,403 |
| 10 kW Class | 30 | 10.05 kW | 646 sq ft | $2,515 | $4,253 |
Which Sibling Wattage & Trim Variants Belong to This Mitrex Series?
Related Mitrex power steps and black/silver trims consolidated into this Mitrex M335-RF041F series guide. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Mitrex M325-RF041F | 325.0 W | 295.8 W | 48.7 V | 40.8 V | 16.25% |
| Mitrex M330-RF041F | 330.0 W | 300.5 W | 48.7 V | 40.8 V | 16.5% |
| Mitrex M335-RF041F | 335.0 W | 305.1 W | 48.8 V | 40.9 V | 16.75% |
| Mitrex M340-RF041F | 340.0 W | 310.9 W | 48.8 V | 40.9 V | 17.0% |
| Mitrex M345-RF041F | 345.0 W | 315.6 W | 48.9 V | 41.0 V | 17.25% |
How Many Mitrex M335-RF041F Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Mitrex M335-RF041F (48.8 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.77 V | 10 panels | 547.7 V | 18 panels |
| -10 C (14 F) | 53.45 V | 11 panels | 588.0 V | 18 panels |
| 0 C (32 F) | 52.12 V | 11 panels | 573.3 V | 19 panels |
| 25 C (77 F STC) | 48.8 V | 12 panels | 585.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Mitrex M335-RF041F?
Four comparable CEC modules such as DEHUI SOLAR POWER INC DH-72P-335W (335.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DEHUI SOLAR POWER INC DH-72P-335W DEHUI SOLAR POWER INC |
335.0 W | Tie (0 W) | 47.8 V | 17.42% | 90.7% |
| BYD Company Limited BYD335P6K-36 BYD Company Limited |
335.0 W | Tie (0 W) | 47.28 V | 17.27% | 91.8% |
| Auxin Solar AXN6M612T335 Auxin Solar |
335.0 W | Tie (0 W) | 47.04 V | 17.26% | 91.7% |
| Bluesun Solar Energy Tech CoLtd BSM335P-72 Bluesun Solar Energy Tech CoLtd |
335.0 W | Tie (0 W) | 46.76 V | 17.29% | 91.4% |
What Are the Design Limits and Best-Fit Uses for Mitrex M335-RF041F?
Evaluate Mitrex M335-RF041F (335.0 W STC, 48.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Mitrex M335-RF041F reaches 54.77 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 517 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (517 sq ft).
- 2026 tax credit baseline: cash residential installs of Mitrex M335-RF041F carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Mitrex M335-RF041F 8 kW Residential Fit
Needs 24 modules (517 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare DEHUI SOLAR POWER INC DH-72P-335W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 305.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Mitrex M335-RF041F by Mitrex grounded in CEC test data and NEC 690.7/690.8 limits. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
How many Mitrex M335-RF041F panels fit on a 600 V winter solar string?
At -10 C (14 F), Mitrex M335-RF041F cold Voc rises from 48.8 V to 53.45 V (beta_Voc -0.272%/C), capping a 600 V string at 11 panels (588.0 V).
How much roof area does an 8 kW array of Mitrex M335-RF041F need?
An 8 kW DC system uses 24 Mitrex M335-RF041F modules (8,040 W STC / 7,322 W PTC), covering roughly 517 sq ft and saving ~$2,012/yr at 18.54 c/kWh.
How does Mitrex M335-RF041F compare against DEHUI SOLAR POWER INC DH-72P-335W?
Mitrex M335-RF041F outputs 335.0 W STC (48.8 V Voc, rank #13,844 of 21,677), while DEHUI SOLAR POWER INC DH-72P-335W delivers 335.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)