Mitrex M310-RF041F is a 310.0 W STC (281.9 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.5% efficiency, 48.5 V Voc at 25 C, and 53.13 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 281.9 W
- Voc @ 25C
- 48.5 V
- Efficiency
- 15.5%
How Does Mitrex M310-RF041F Compare Against Peer CEC Listings?
Solar engineering breakdown for Mitrex M310-RF041F: PTC thermal retention, roof footprint, and cold Voc string bounds. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Across 5,889 Mono-c-Si listings from Mitrex and peers, Mitrex M310-RF041F stands 100.0 W below the 410.0 W Mono-c-Si median and typical 90.9% PTC-to-STC thermal output (281.9 W real-world rating). Sizing 6 kW (20 panels) to 10 kW (33 panels) yields $1,552-$2,560/yr in baseline US bill offset. Higher 48.5 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Mitrex M310-RF041F Fall Across Listed CEC Models?
Distribution marker showing Mitrex M310-RF041F (310.0 W) relative to the 385.0 W all-CEC solar panel median. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Dataset Percentiles Define Mitrex M310-RF041F?
Dataset percentiles tracking Mitrex M310-RF041F power output, thermal retention ratio, and aperture efficiency against 21,677 models. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Do the Dataset Ranks Show for Mitrex M310-RF041F?
Benchmark highlights for Mitrex M310-RF041F covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.5% Aperture Efficiency
Power density 155.0 W/m2 (4.41 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.13 V at -10 C (584.4 V string) and 54.46 V at -20 C (11 max).
26 Panels = 8,060 W STC
Occupies 52.0 m2 (560 sq ft) producing 7,329 W PTC; NEC 690.8 OCPD floor is 12.53 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.5 * (1 + (-0.273/100) * (-10 - 25)) = 53.13 V | OCPD = 1.56 * 8.03 = 12.53 A
Inputs from CEC Modules.csv for Mitrex M310-RF041F: Voc=48.5 V, beta_Voc=-0.273%/C, Isc=8.03 A, STC=310.0 W, Area=2.0 m2.
Result: 11 panels max on 600 V (584.4 V); 26 panels for 8 kW (560 sq ft).
What Are the Published CEC Specifications for Mitrex M310-RF041F?
Official CEC datasheet figures for Mitrex M310-RF041F (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 281.9 W (90.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.03 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.6 V / 7.64 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.273 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.5% (2.0 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Mitrex M310-RF041F Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Mitrex M310-RF041F modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 431 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 560 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 710 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Mitrex Series?
Consolidated Mitrex wattage variants sharing the Mitrex M310-RF041F mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Mitrex M300-RF041F | 300.0 W | 272.6 W | 48.4 V | 40.5 V | 15.0% |
| Mitrex M305-RF041F | 305.0 W | 277.2 W | 48.5 V | 40.6 V | 15.25% |
| Mitrex M310-RF041F | 310.0 W | 281.9 W | 48.5 V | 40.6 V | 15.5% |
| Mitrex M315-RF041F | 315.0 W | 286.6 W | 48.6 V | 40.7 V | 15.75% |
| Mitrex M320-RF041F | 320.0 W | 291.1 W | 48.6 V | 40.7 V | 16.0% |
How Many Mitrex M310-RF041F Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Mitrex M310-RF041F (53.13 V at 14 F). All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.46 V | 11 panels | 599.1 V | 18 panels |
| -10 C (14 F) | 53.13 V | 11 panels | 584.4 V | 18 panels |
| 0 C (32 F) | 51.81 V | 11 panels | 569.9 V | 19 panels |
| 25 C (77 F STC) | 48.5 V | 12 panels | 582.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Mitrex M310-RF041F?
Competing CEC solar panels closest to Mitrex M310-RF041F in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6612P-310.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612P-310 Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 45.8 V | 15.98% | 90.3% |
| Centrosolar America CP72 310-C1 Centrosolar America |
310.0 W | Tie (0 W) | 45.8 V | 15.98% | 90.3% |
| BYD Company Limited BYD 310P6C-36 BYD Company Limited |
310.0 W | Tie (0 W) | 45.79 V | 15.98% | 91.2% |
| BYD Company Limited BYD310P6K-36 BYD Company Limited |
310.0 W | Tie (0 W) | 45.79 V | 15.98% | 91.6% |
What Are the Design Limits and Best-Fit Uses for Mitrex M310-RF041F?
Evaluate Mitrex M310-RF041F (310.0 W STC, 48.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Mitrex M310-RF041F reaches 54.46 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 560 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (560 sq ft).
- 2026 tax credit baseline: cash residential installs of Mitrex M310-RF041F carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Mitrex M310-RF041F 8 kW Residential Fit
Needs 26 modules (560 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612P-310.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 281.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Mitrex M310-RF041F by Mitrex grounded in CEC test data and NEC 690.7/690.8 limits. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What fuse or breaker size does NEC 690.8 require for Mitrex M310-RF041F?
Multiplying Mitrex M310-RF041F's 8.03 A short-circuit current by 1.56 equals 12.53 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Mitrex M310-RF041F before finalizing component orders.
Can Mitrex M310-RF041F pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.13 V cold Voc at 14 F and handles 8.03 A Isc; string inverters cap Mitrex M310-RF041F at 11 panels on 600 V.
Is Mitrex M310-RF041F eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mitrex M310-RF041F rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)