Manufacturer: Merlin Solar Technologies Inc Registry: CEC Verified Engineering Specification

Merlin Solar Technologies Inc RFP-F036B170S is a 170.0 W STC (152.2 W PTC) Mono-c-Si solar module ranking #21,323 of 21,677 CEC listings (below all-CEC median; higher than 1.5% of peers). It delivers 15.6% efficiency, 24.36 V Voc at 25 C, and 26.63 V cold Voc at -10 C (22 panels max per 600 V string).

STC Wattage
170.0 W
PTC Wattage
152.2 W
Voc @ 25C
24.36 V
Efficiency
15.6%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Merlin Solar Technologies Inc RFP-F036B170S Compare Against Peer CEC Listings?

Solar engineering breakdown for Merlin Solar Technologies Inc RFP-F036B170S: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 170.0 W STC and 152.2 W PTC, Merlin Solar Technologies Inc RFP-F036B170S sits -215.0 W vs all-CEC median (below all-CEC median; higher than 1.5% of peers) among 21,677 listed modules. Power density reaches 156.0 W/m2 (4.31 percentage points below 19.91% CEC median). Lower 24.36 V string voltage fits 22 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 37 panels in series. Alternative peer Walters & Wolf Glass Co VL-C300-1-0904-175W-M rates 175.0 W.

Where Does Merlin Solar Technologies Inc RFP-F036B170S Fall Across Listed CEC Models?

Distribution marker showing Merlin Solar Technologies Inc RFP-F036B170S (170.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Merlin Solar Technologies Inc RFP-F036B170S (170.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMerlin Solar Techn: 170.0 W

What Dataset Percentiles Define Merlin Solar Technologies Inc RFP-F036B170S?

Dataset percentiles tracking Merlin Solar Technologies Inc RFP-F036B170S power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Merlin Solar Technologies Inc RFP-F036B170S Engineering BenchmarksPercentile comparison of Merlin Solar Technologies Inc RFP-F036B170S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage170.0 WPTC/STC Retention89.5%Module Efficiency15.6%

What Do the Dataset Ranks Show for Merlin Solar Technologies Inc RFP-F036B170S?

Benchmark highlights for Merlin Solar Technologies Inc RFP-F036B170S covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,323 / 21,677

170.0 W STC · Higher Than 1.5%

170.0 W STC (-215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,797

15.6% Aperture Efficiency

Power density 156.0 W/m2 (4.31 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).

NEC 690.7 Limit

22 Panels Max @ -10 C (600 V)

Cold Voc reaches 26.63 V at -10 C (585.9 V string) and 27.28 V at -20 C (21 max).

8 kW Reference Array

48 Panels = 8,160 W STC

Occupies 52.3 m2 (563 sq ft) producing 7,306 W PTC; NEC 690.8 OCPD floor is 13.98 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 24.36 * (1 + (-0.266/100) * (-10 - 25)) = 26.63 V | OCPD = 1.56 * 8.96 = 13.98 A

Inputs from CEC Modules.csv for Merlin Solar Technologies Inc RFP-F036B170S: Voc=24.36 V, beta_Voc=-0.266%/C, Isc=8.96 A, STC=170.0 W, Area=1.09 m2.

Result: 22 panels max on 600 V (585.9 V); 48 panels for 8 kW (563 sq ft).

What Are the Published CEC Specifications for Merlin Solar Technologies Inc RFP-F036B170S?

Official CEC datasheet figures for Merlin Solar Technologies Inc RFP-F036B170S (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Merlin Solar Technologies Inc RFP-F036B170S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 170.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 152.2 W (89.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 24.36 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.96 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 20.07 V / 8.49 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.6% (1.09 m2) Array roof footprint density
Cell Count & Technology 36 cells (Mono-c-Si) Monofacial backsheet

How Many Merlin Solar Technologies Inc RFP-F036B170S Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Merlin Solar Technologies Inc RFP-F036B170S modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 36 6.12 kW 422 sq ft $1,532 $2,590
8 kW Class 48 8.16 kW 563 sq ft $2,042 $3,454
10 kW Class 59 10.03 kW 692 sq ft $2,510 $4,245

How Many Merlin Solar Technologies Inc RFP-F036B170S Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Merlin Solar Technologies Inc RFP-F036B170S (26.63 V at 14 F).

Computed from Voc=24.36V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 27.28 V 21 panels 572.9 V 36 panels
-10 C (14 F) 26.63 V 22 panels 585.9 V 37 panels
0 C (32 F) 25.98 V 23 panels 597.5 V 38 panels
25 C (77 F STC) 24.36 V 24 panels 584.6 V 41 panels

Which Cross-Brand Solar Modules Compare Closest to Merlin Solar Technologies Inc RFP-F036B170S?

Competing CEC solar panels closest to Merlin Solar Technologies Inc RFP-F036B170S in nameplate wattage and Voc, starting with Walters & Wolf Glass Co VL-C300-1-0904-175W-M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Walters & Wolf Glass Co VL-C300-1-0904-175W-M
Walters & Wolf Glass Co
175.0 W +5.0 W 25.03 V 15.49% 92.9%
Trina Solar TSM-175PEG4007
Trina Solar
175.0 W +5.0 W 25.4 V 10.64% 88.1%
Trina Solar TSM-160PEG4007
Trina Solar
160.0 W -10.0 W 24.9 V 9.73% 87.9%
Grenzebach Envelon GmbH ON Generate-36-S1
Grenzebach Envelon GmbH
185.0 W +15.0 W 24.28 V 16.37% 91.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Merlin Solar Technologies Inc RFP-F036B170S?

Evaluate Merlin Solar Technologies Inc RFP-F036B170S (170.0 W STC, 24.36 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Merlin Solar Technologies Inc RFP-F036B170S reaches 27.28 V per panel—exceeding 21 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 48 panels for an 8 kW build require 563 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 48 panels (563 sq ft).
  • 2026 tax credit baseline: cash residential installs of Merlin Solar Technologies Inc RFP-F036B170S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Merlin Solar Technologies Inc RFP-F036B170S 8 kW Residential Fit

Needs 48 modules (563 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 22 panels (-10 C) or 21 panels (-20 C), or compare Walters & Wolf Glass Co VL-C300-1-0904-175W-M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 152.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Merlin Solar Technologies Inc RFP-F036B170S by Merlin Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many Merlin Solar Technologies Inc RFP-F036B170S panels fit on a 600 V winter solar string?

At -10 C (14 F), Merlin Solar Technologies Inc RFP-F036B170S cold Voc rises from 24.36 V to 26.63 V (beta_Voc -0.266%/C), capping a 600 V string at 22 panels (585.9 V).

How much roof area does an 8 kW array of Merlin Solar Technologies Inc RFP-F036B170S need?

An 8 kW DC system uses 48 Merlin Solar Technologies Inc RFP-F036B170S modules (8,160 W STC / 7,306 W PTC), covering roughly 563 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does Merlin Solar Technologies Inc RFP-F036B170S compare against Walters & Wolf Glass Co VL-C300-1-0904-175W-M?

Merlin Solar Technologies Inc RFP-F036B170S outputs 170.0 W STC (24.36 V Voc, rank #21,323 of 21,677), while Walters & Wolf Glass Co VL-C300-1-0904-175W-M delivers 175.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.