Merlin Solar Technologies Inc RFP-F036B170S is a 170.0 W STC (152.2 W PTC) Mono-c-Si solar module ranking #21,323 of 21,677 CEC listings (below all-CEC median; higher than 1.5% of peers). It delivers 15.6% efficiency, 24.36 V Voc at 25 C, and 26.63 V cold Voc at -10 C (22 panels max per 600 V string).
- STC Wattage
- 170.0 W
- PTC Wattage
- 152.2 W
- Voc @ 25C
- 24.36 V
- Efficiency
- 15.6%
How Does Merlin Solar Technologies Inc RFP-F036B170S Compare Against Peer CEC Listings?
Solar engineering breakdown for Merlin Solar Technologies Inc RFP-F036B170S: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 170.0 W STC and 152.2 W PTC, Merlin Solar Technologies Inc RFP-F036B170S sits -215.0 W vs all-CEC median (below all-CEC median; higher than 1.5% of peers) among 21,677 listed modules. Power density reaches 156.0 W/m2 (4.31 percentage points below 19.91% CEC median). Lower 24.36 V string voltage fits 22 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 37 panels in series. Alternative peer Walters & Wolf Glass Co VL-C300-1-0904-175W-M rates 175.0 W.
Where Does Merlin Solar Technologies Inc RFP-F036B170S Fall Across Listed CEC Models?
Distribution marker showing Merlin Solar Technologies Inc RFP-F036B170S (170.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Merlin Solar Technologies Inc RFP-F036B170S?
Dataset percentiles tracking Merlin Solar Technologies Inc RFP-F036B170S power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Merlin Solar Technologies Inc RFP-F036B170S?
Benchmark highlights for Merlin Solar Technologies Inc RFP-F036B170S covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
170.0 W STC · Higher Than 1.5%
170.0 W STC (-215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.6% Aperture Efficiency
Power density 156.0 W/m2 (4.31 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).
22 Panels Max @ -10 C (600 V)
Cold Voc reaches 26.63 V at -10 C (585.9 V string) and 27.28 V at -20 C (21 max).
48 Panels = 8,160 W STC
Occupies 52.3 m2 (563 sq ft) producing 7,306 W PTC; NEC 690.8 OCPD floor is 13.98 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 24.36 * (1 + (-0.266/100) * (-10 - 25)) = 26.63 V | OCPD = 1.56 * 8.96 = 13.98 A
Inputs from CEC Modules.csv for Merlin Solar Technologies Inc RFP-F036B170S: Voc=24.36 V, beta_Voc=-0.266%/C, Isc=8.96 A, STC=170.0 W, Area=1.09 m2.
Result: 22 panels max on 600 V (585.9 V); 48 panels for 8 kW (563 sq ft).
What Are the Published CEC Specifications for Merlin Solar Technologies Inc RFP-F036B170S?
Official CEC datasheet figures for Merlin Solar Technologies Inc RFP-F036B170S (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 170.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 152.2 W (89.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 24.36 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.96 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 20.07 V / 8.49 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.266 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.6% (1.09 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Mono-c-Si) | Monofacial backsheet |
How Many Merlin Solar Technologies Inc RFP-F036B170S Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Merlin Solar Technologies Inc RFP-F036B170S modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 36 | 6.12 kW | 422 sq ft | $1,532 | $2,590 |
| 8 kW Class | 48 | 8.16 kW | 563 sq ft | $2,042 | $3,454 |
| 10 kW Class | 59 | 10.03 kW | 692 sq ft | $2,510 | $4,245 |
How Many Merlin Solar Technologies Inc RFP-F036B170S Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Merlin Solar Technologies Inc RFP-F036B170S (26.63 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 27.28 V | 21 panels | 572.9 V | 36 panels |
| -10 C (14 F) | 26.63 V | 22 panels | 585.9 V | 37 panels |
| 0 C (32 F) | 25.98 V | 23 panels | 597.5 V | 38 panels |
| 25 C (77 F STC) | 24.36 V | 24 panels | 584.6 V | 41 panels |
Which Cross-Brand Solar Modules Compare Closest to Merlin Solar Technologies Inc RFP-F036B170S?
Competing CEC solar panels closest to Merlin Solar Technologies Inc RFP-F036B170S in nameplate wattage and Voc, starting with Walters & Wolf Glass Co VL-C300-1-0904-175W-M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Walters & Wolf Glass Co VL-C300-1-0904-175W-M Walters & Wolf Glass Co |
175.0 W | +5.0 W | 25.03 V | 15.49% | 92.9% |
| Trina Solar TSM-175PEG4007 Trina Solar |
175.0 W | +5.0 W | 25.4 V | 10.64% | 88.1% |
| Trina Solar TSM-160PEG4007 Trina Solar |
160.0 W | -10.0 W | 24.9 V | 9.73% | 87.9% |
| Grenzebach Envelon GmbH ON Generate-36-S1 Grenzebach Envelon GmbH |
185.0 W | +15.0 W | 24.28 V | 16.37% | 91.0% |
What Are the Design Limits and Best-Fit Uses for Merlin Solar Technologies Inc RFP-F036B170S?
Evaluate Merlin Solar Technologies Inc RFP-F036B170S (170.0 W STC, 24.36 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Merlin Solar Technologies Inc RFP-F036B170S reaches 27.28 V per panel—exceeding 21 panels in series voids 600 V inverter warranties.
- Footprint constraint: 48 panels for an 8 kW build require 563 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 48 panels (563 sq ft).
- 2026 tax credit baseline: cash residential installs of Merlin Solar Technologies Inc RFP-F036B170S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Merlin Solar Technologies Inc RFP-F036B170S 8 kW Residential Fit
Needs 48 modules (563 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 22 panels (-10 C) or 21 panels (-20 C), or compare Walters & Wolf Glass Co VL-C300-1-0904-175W-M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 152.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Merlin Solar Technologies Inc RFP-F036B170S by Merlin Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many Merlin Solar Technologies Inc RFP-F036B170S panels fit on a 600 V winter solar string?
At -10 C (14 F), Merlin Solar Technologies Inc RFP-F036B170S cold Voc rises from 24.36 V to 26.63 V (beta_Voc -0.266%/C), capping a 600 V string at 22 panels (585.9 V).
How much roof area does an 8 kW array of Merlin Solar Technologies Inc RFP-F036B170S need?
An 8 kW DC system uses 48 Merlin Solar Technologies Inc RFP-F036B170S modules (8,160 W STC / 7,306 W PTC), covering roughly 563 sq ft and saving ~$2,042/yr at 18.54 c/kWh.
How does Merlin Solar Technologies Inc RFP-F036B170S compare against Walters & Wolf Glass Co VL-C300-1-0904-175W-M?
Merlin Solar Technologies Inc RFP-F036B170S outputs 170.0 W STC (24.36 V Voc, rank #21,323 of 21,677), while Walters & Wolf Glass Co VL-C300-1-0904-175W-M delivers 175.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)