LONGi Green Energy Technology Co Ltd LR6-60HPB-310M is a 310.0 W STC (289.3 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 19.1% efficiency, 40.3 V Voc at 25 C, and 44.07 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 289.3 W
- Voc @ 25C
- 40.3 V
- Efficiency
- 19.1%
How Does LONGi Green Energy Technology Co Ltd LR6-60HPB-310M Compare Against Peer CEC Listings?
Solar engineering breakdown for LONGi Green Energy Technology Co Ltd LR6-60HPB-310M: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 310.0 W STC and 289.3 W PTC, LONGi Green Energy Technology Co Ltd LR6-60HPB-310M sits -75.0 W vs all-CEC median (below all-CEC median; higher than 25.6% of peers) among 21,677 listed modules. Power density reaches 191.0 W/m2 (0.81 percentage points below 19.91% CEC median). Mid-range 40.3 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer DualSun SAS DualSun 310M-60-00 rates 310.0 W.
Where Does LONGi Green Energy Technology Co Ltd LR6-60HPB-310M Fall Across Listed CEC Models?
Distribution marker showing LONGi Green Energy Technology Co Ltd LR6-60HPB-310M (310.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define LONGi Green Energy Technology Co Ltd LR6-60HPB-310M?
Dataset percentiles tracking LONGi Green Energy Technology Co Ltd LR6-60HPB-310M power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for LONGi Green Energy Technology Co Ltd LR6-60HPB-310M?
Benchmark highlights for LONGi Green Energy Technology Co Ltd LR6-60HPB-310M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.1% Aperture Efficiency
Power density 191.0 W/m2 (0.81 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.07 V at -10 C (572.9 V string) and 45.14 V at -20 C (13 max).
26 Panels = 8,060 W STC
Occupies 42.2 m2 (454 sq ft) producing 7,522 W PTC; NEC 690.8 OCPD floor is 15.38 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.3 * (1 + (-0.267/100) * (-10 - 25)) = 44.07 V | OCPD = 1.56 * 9.86 = 15.38 A
Inputs from CEC Modules.csv for LONGi Green Energy Technology Co Ltd LR6-60HPB-310M: Voc=40.3 V, beta_Voc=-0.267%/C, Isc=9.86 A, STC=310.0 W, Area=1.623 m2.
Result: 13 panels max on 600 V (572.9 V); 26 panels for 8 kW (454 sq ft).
What Are the Published CEC Specifications for LONGi Green Energy Technology Co Ltd LR6-60HPB-310M?
Official CEC datasheet figures for LONGi Green Energy Technology Co Ltd LR6-60HPB-310M (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 289.3 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.86 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.3 V / 9.3 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.267 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.1% (1.623 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many LONGi Green Energy Technology Co Ltd LR6-60HPB-310M Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many LONGi Green Energy Technology Co Ltd LR6-60HPB-310M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 349 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 454 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 577 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This LONGi Green Energy Technology Co Ltd Series?
Consolidated LONGi Green Energy Technology Co Ltd wattage variants sharing the LONGi Green Energy Technology Co Ltd LR6-60HPB-310M mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| LONGi Green Energy Technology Co Ltd LR6-60HPB-300M | 300.0 W | 279.7 W | 39.8 V | 32.9 V | 18.48% |
| LONGi Green Energy Technology Co Ltd LR6-60HPB-305M | 305.0 W | 284.5 W | 40.1 V | 33.1 V | 18.79% |
| LONGi Green Energy Technology Co Ltd LR6-60HPB-310M | 310.0 W | 289.3 W | 40.3 V | 33.3 V | 19.1% |
| LONGi Green Energy Technology Co Ltd LR6-60HPB-315M | 315.0 W | 294.1 W | 40.6 V | 33.7 V | 19.41% |
| LONGi Green Energy Technology Co Ltd LR6-60HPB-320M | 320.0 W | 298.9 W | 40.9 V | 33.9 V | 19.72% |
How Many LONGi Green Energy Technology Co Ltd LR6-60HPB-310M Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on LONGi Green Energy Technology Co Ltd LR6-60HPB-310M (44.07 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.14 V | 13 panels | 586.8 V | 22 panels |
| -10 C (14 F) | 44.07 V | 13 panels | 572.9 V | 22 panels |
| 0 C (32 F) | 42.99 V | 13 panels | 558.9 V | 23 panels |
| 25 C (77 F STC) | 40.3 V | 14 panels | 564.2 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to LONGi Green Energy Technology Co Ltd LR6-60HPB-310M?
Competing CEC solar panels closest to LONGi Green Energy Technology Co Ltd LR6-60HPB-310M in nameplate wattage and Voc, starting with DualSun SAS DualSun 310M-60-00.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DualSun SAS DualSun 310M-60-00 DualSun SAS |
310.0 W | Tie (0 W) | 40.3 V | 18.9% | 91.4% |
| Bluesun Solar Energy Tech CoLtd BSM310M-60 Bluesun Solar Energy Tech CoLtd |
310.0 W | Tie (0 W) | 40.18 V | 19.02% | 91.9% |
| Boviet Solar Technology Co Ltd BVM6610M-310 Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.05% | 92.2% |
| Boviet Solar Technology Co Ltd BVM6610M-310-H Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.02% | 93.1% |
What Are the Design Limits and Best-Fit Uses for LONGi Green Energy Technology Co Ltd LR6-60HPB-310M?
Evaluate LONGi Green Energy Technology Co Ltd LR6-60HPB-310M (310.0 W STC, 40.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), LONGi Green Energy Technology Co Ltd LR6-60HPB-310M reaches 45.14 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 454 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (454 sq ft).
- 2026 tax credit baseline: cash residential installs of LONGi Green Energy Technology Co Ltd LR6-60HPB-310M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
LONGi Green Energy Technology Co Ltd LR6-60HPB-310M 8 kW Residential Fit
Needs 26 modules (454 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DualSun SAS DualSun 310M-60-00.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 289.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for LONGi Green Energy Technology Co Ltd LR6-60HPB-310M by LONGi Green Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many LONGi Green Energy Technology Co Ltd LR6-60HPB-310M panels fit on a 600 V winter solar string?
At -10 C (14 F), LONGi Green Energy Technology Co Ltd LR6-60HPB-310M cold Voc rises from 40.3 V to 44.07 V (beta_Voc -0.267%/C), capping a 600 V string at 13 panels (572.9 V).
How much roof area does an 8 kW array of LONGi Green Energy Technology Co Ltd LR6-60HPB-310M need?
An 8 kW DC system uses 26 LONGi Green Energy Technology Co Ltd LR6-60HPB-310M modules (8,060 W STC / 7,522 W PTC), covering roughly 454 sq ft and saving ~$2,017/yr at 18.54 c/kWh.
How does LONGi Green Energy Technology Co Ltd LR6-60HPB-310M compare against DualSun SAS DualSun 310M-60-00?
LONGi Green Energy Technology Co Ltd LR6-60HPB-310M outputs 310.0 W STC (40.3 V Voc, rank #15,760 of 21,677), while DualSun SAS DualSun 310M-60-00 delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)