LONGi Green Energy Technology Co Ltd LR5-54HABB-395M is a 395.0 W STC (369.3 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.79% efficiency, 36.81 V Voc at 25 C, and 40.2 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 369.3 W
- Voc @ 25C
- 36.81 V
- Efficiency
- 20.79%
How Does LONGi Green Energy Technology Co Ltd LR5-54HABB-395M Compare Against Peer CEC Listings?
How LONGi Green Energy Technology Co Ltd LONGi Green Energy Technology Co Ltd LR5-54HABB-395M handles rooftop heat (369.3 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, LONGi Green Energy Technology Co Ltd LR5-54HABB-395M exhibits 13.65 A short-circuit current, requiring a 21.29 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #9,869 of 21,677 (15.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 39.9 m2 for an 8 kW system (26 panels for 10 kW). Lower 36.81 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does LONGi Green Energy Technology Co Ltd LR5-54HABB-395M Fall Across Listed CEC Models?
Where LONGi Green Energy Technology Co Ltd LR5-54HABB-395M (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define LONGi Green Energy Technology Co Ltd LR5-54HABB-395M?
Percentile placement of LONGi Green Energy Technology Co Ltd LR5-54HABB-395M across power density (207.9 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for LONGi Green Energy Technology Co Ltd LR5-54HABB-395M?
Four critical engineering numbers homeowners and solar installers check first when reviewing LONGi Green Energy Technology Co Ltd LR5-54HABB-395M specifications.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.79% Aperture Efficiency
Power density 207.9 W/m2 (0.88 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.2 V at -10 C (562.8 V string) and 41.17 V at -20 C (14 max).
21 Panels = 8,295 W STC
Occupies 39.9 m2 (429 sq ft) producing 7,755 W PTC; NEC 690.8 OCPD floor is 21.29 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.81 * (1 + (-0.263/100) * (-10 - 25)) = 40.2 V | OCPD = 1.56 * 13.65 = 21.29 A
Inputs from CEC Modules.csv for LONGi Green Energy Technology Co Ltd LR5-54HABB-395M: Voc=36.81 V, beta_Voc=-0.263%/C, Isc=13.65 A, STC=395.0 W, Area=1.9 m2.
Result: 14 panels max on 600 V (562.8 V); 21 panels for 8 kW (429 sq ft).
What Are the Published CEC Specifications for LONGi Green Energy Technology Co Ltd LR5-54HABB-395M?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for LONGi Green Energy Technology Co Ltd LR5-54HABB-395M.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 369.3 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.81 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.65 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.7 V / 12.87 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.263 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.79% (1.9 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many LONGi Green Energy Technology Co Ltd LR5-54HABB-395M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using LONGi Green Energy Technology Co Ltd LR5-54HABB-395M (395.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 327 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 429 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 532 sq ft | $2,570 | $4,347 |
How Many LONGi Green Energy Technology Co Ltd LR5-54HABB-395M Modules Fit in a Cold-Weather String?
Maximum series module counts for LONGi Green Energy Technology Co Ltd LR5-54HABB-395M from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.17 V | 14 panels | 576.4 V | 24 panels |
| -10 C (14 F) | 40.2 V | 14 panels | 562.8 V | 24 panels |
| 0 C (32 F) | 39.23 V | 15 panels | 588.4 V | 25 panels |
| 25 C (77 F STC) | 36.81 V | 16 panels | 589.0 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to LONGi Green Energy Technology Co Ltd LR5-54HABB-395M?
Alternative CEC solar modules from competing brands near LONGi Green Energy Technology Co Ltd LR5-54HABB-395M (395.0 W), including ASTORIOS Holding Inc ASTR108BDG-395W-US.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ASTORIOS Holding Inc ASTR108BDG-395W-US ASTORIOS Holding Inc |
395.0 W | Tie (0 W) | 36.9 V | 20.36% | 92.9% |
| AXITEC AC-395MBT/108V AXITEC |
395.0 W | Tie (0 W) | 37.0 V | 20.47% | 93.3% |
| Elin Energy (Sirius PV) ELNSM54M-HC-BF-395 Elin Energy (Sirius PV) |
395.0 W | Tie (0 W) | 37.02 V | 20.36% | 94.3% |
| Belinus Solar BV BE-M7-GG-108-395 Belinus Solar BV |
395.0 W | Tie (0 W) | 37.03 V | 20.26% | 93.8% |
What Are the Design Limits and Best-Fit Uses for LONGi Green Energy Technology Co Ltd LR5-54HABB-395M?
Evaluate LONGi Green Energy Technology Co Ltd LR5-54HABB-395M (395.0 W STC, 36.81 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), LONGi Green Energy Technology Co Ltd LR5-54HABB-395M reaches 41.17 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 429 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (429 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of LONGi Green Energy Technology Co Ltd LR5-54HABB-395M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
LONGi Green Energy Technology Co Ltd LR5-54HABB-395M 8 kW Residential Fit
Needs 21 modules (429 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ASTORIOS Holding Inc ASTR108BDG-395W-US.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 369.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for LONGi Green Energy Technology Co Ltd LR5-54HABB-395M by LONGi Green Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is LONGi Green Energy Technology Co Ltd LR5-54HABB-395M PTC wattage (369.3 W) lower than STC (395.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 369.3 W PTC (93.5% retention) across LONGi Green Energy Technology Co Ltd LR5-54HABB-395M's 1.9 m2 aperture.
Who should skip LONGi Green Energy Technology Co Ltd LR5-54HABB-395M on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 LONGi Green Energy Technology Co Ltd LR5-54HABB-395M panels (429 sq ft) leave unusable roof gaps vs. ASTORIOS Holding Inc ASTR108BDG-395W-US.
What is the 1,000 V commercial string limit for LONGi Green Energy Technology Co Ltd LR5-54HABB-395M?
On 1,000 V commercial inverters at -10 C (40.2 V cold Voc), LONGi Green Energy Technology Co Ltd LR5-54HABB-395M fits up to 24 panels per series string.