Skip to main content
WireAndSun
Calculators
CEC PV Module

LOF SOLAR CORP LOF-MH82-C385 — CEC Solar Module Specifications

Manufacturer: LOF SOLAR CORP Registry: CEC Verified Engineering Specification

LOF SOLAR CORP LOF-MH82-C385 is a 385.0 W STC (355.2 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.44% efficiency, 44.15 V Voc at 25 C, and 49.14 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
385.0 W
PTC Wattage
355.2 W
Voc @ 25C
44.15 V
Efficiency
19.44%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does LOF SOLAR CORP LOF-MH82-C385 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for LOF SOLAR CORP LOF-MH82-C385 (Mono-c-Si) residential solar systems.

Homeowners evaluating LOF SOLAR CORP LOF-MH82-C385 need 16 panels for 6 kW or 21 panels (448 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (448 sq ft). Under NEC 690.7(A), beta_Voc (-0.323%/C) pushes open-circuit voltage to 49.14 V at 14 F and 50.57 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does LOF SOLAR CORP LOF-MH82-C385 Fall Across Listed CEC Models?

Comparison of LOF SOLAR CORP LOF-MH82-C385 (385.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where LOF SOLAR CORP LOF-MH82-C385 (385.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLOF SOLAR CORP LOF: 385.0 W

What Dataset Percentiles Define LOF SOLAR CORP LOF-MH82-C385?

Relative ranking of LOF SOLAR CORP LOF-MH82-C385 across nameplate watts, 92.3% PTC thermal ratio, and module aperture efficiency.

LOF SOLAR CORP LOF-MH82-C385 Engineering BenchmarksPercentile comparison of LOF SOLAR CORP LOF-MH82-C385 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage385.0 WPTC/STC Retention92.3%Module Efficiency19.44%

What Do the Dataset Ranks Show for LOF SOLAR CORP LOF-MH82-C385?

Summary of LOF SOLAR CORP LOF-MH82-C385 output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.

Rank #10,723 / 21,677

385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,328

19.44% Aperture Efficiency

Power density 194.4 W/m2 (0.47 percentage points below 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.14 V at -10 C (589.7 V string) and 50.57 V at -20 C (11 max).

8 kW Reference Array

21 Panels = 8,085 W STC

Occupies 41.6 m2 (448 sq ft) producing 7,459 W PTC; NEC 690.8 OCPD floor is 16.86 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.15 * (1 + (-0.323/100) * (-10 - 25)) = 49.14 V | OCPD = 1.56 * 10.81 = 16.86 A

Inputs from CEC Modules.csv for LOF SOLAR CORP LOF-MH82-C385: Voc=44.15 V, beta_Voc=-0.323%/C, Isc=10.81 A, STC=385.0 W, Area=1.98 m2.

Result: 12 panels max on 600 V (589.7 V); 21 panels for 8 kW (448 sq ft).

What Are the Published CEC Specifications for LOF SOLAR CORP LOF-MH82-C385?

Complete CEC test sheet for LOF SOLAR CORP LOF-MH82-C385 including Isc (10.81 A), Voc (44.15 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for LOF SOLAR CORP LOF-MH82-C385.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 385.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 355.2 W (92.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.15 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.81 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.45 V / 10.29 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.323 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.44% (1.98 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many LOF SOLAR CORP LOF-MH82-C385 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using LOF SOLAR CORP LOF-MH82-C385.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.16 kW 341 sq ft $1,542 $2,607
8 kW Class 21 8.09 kW 448 sq ft $2,025 $3,424
10 kW Class 26 10.01 kW 554 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This LOF SOLAR CORP Series?

Related LOF SOLAR CORP power steps and black/silver trims consolidated into this LOF SOLAR CORP LOF-MH82-C385 series guide.

Sibling CEC listings grouped into the LOF SOLAR CORP LOF-MH82-C385 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
LOF SOLAR CORP LOF-MH82-C375 375.0 W 345.7 W 43.85 V 37.15 V 18.94%
LOF SOLAR CORP LOF-MH82-C380 380.0 W 350.4 W 44.0 V 37.3 V 19.19%
LOF SOLAR CORP LOF-MH82-C385 385.0 W 355.2 W 44.15 V 37.45 V 19.44%
LOF SOLAR CORP LOF-MH82-C390 390.0 W 359.9 W 44.3 V 37.6 V 19.7%
LOF SOLAR CORP LOF-MH82-C395 395.0 W 364.7 W 44.45 V 37.78 V 19.95%

How Many LOF SOLAR CORP LOF-MH82-C385 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for LOF SOLAR CORP LOF-MH82-C385 (44.15 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.15V and beta_Voc=-0.323%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.57 V 11 panels 556.3 V 19 panels
-10 C (14 F) 49.14 V 12 panels 589.7 V 20 panels
0 C (32 F) 47.72 V 12 panels 572.6 V 20 panels
25 C (77 F STC) 44.15 V 13 panels 573.9 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to LOF SOLAR CORP LOF-MH82-C385?

Four comparable CEC modules such as CSI Solar Co Ltd CS3N-385MS {Blk} (385.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3N-385MS {Blk}
CSI Solar Co Ltd
385.0 W Tie (0 W) 43.9 V 19.54% 93.4%
CSI Solar Co Ltd CS3N-385MS {Wht}
CSI Solar Co Ltd
385.0 W Tie (0 W) 43.9 V 19.54% 93.4%
EMMVEE Photovoltaic Power Private Limited E385M72-B
EMMVEE Photovoltaic Power Private Limited
385.0 W Tie (0 W) 45.9 V 19.32% 91.5%
CSI Solar Co Ltd CS3L-385MS
CSI Solar Co Ltd
385.0 W Tie (0 W) 41.4 V 21.51% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for LOF SOLAR CORP LOF-MH82-C385?

Evaluate LOF SOLAR CORP LOF-MH82-C385 (385.0 W STC, 44.15 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), LOF SOLAR CORP LOF-MH82-C385 reaches 50.57 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 448 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (448 sq ft).
  • 2026 tax credit baseline: cash residential installs of LOF SOLAR CORP LOF-MH82-C385 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

LOF SOLAR CORP LOF-MH82-C385 8 kW Residential Fit

Needs 21 modules (448 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3N-385MS {Blk}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 355.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for LOF SOLAR CORP LOF-MH82-C385 by LOF SOLAR CORP grounded in CEC test data and NEC 690.7/690.8 limits.

Why is LOF SOLAR CORP LOF-MH82-C385 PTC wattage (355.2 W) lower than STC (385.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 355.2 W PTC (92.3% retention) across LOF SOLAR CORP LOF-MH82-C385's 1.98 m2 aperture.

Who should skip LOF SOLAR CORP LOF-MH82-C385 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 LOF SOLAR CORP LOF-MH82-C385 panels (448 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3N-385MS {Blk}.

What is the 1,000 V commercial string limit for LOF SOLAR CORP LOF-MH82-C385?

On 1,000 V commercial inverters at -10 C (49.14 V cold Voc), LOF SOLAR CORP LOF-MH82-C385 fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting LOF SOLAR CORP LOF-MH82-C385.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.