Manufacturer: LOF SOLAR CORP Registry: CEC Verified Engineering Specification

LOF SOLAR CORP LOF-MH62-C380 is a 380.0 W STC (351.4 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 21.11% efficiency, 41.0 V Voc at 25 C, and 45.64 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
380.0 W
PTC Wattage
351.4 W
Voc @ 25C
41.0 V
Efficiency
21.11%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does LOF SOLAR CORP LOF-MH62-C380 Compare Against Peer CEC Listings?

Solar engineering breakdown for LOF SOLAR CORP LOF-MH62-C380: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 380.0 W STC and 351.4 W PTC, LOF SOLAR CORP LOF-MH62-C380 sits -5.0 W vs all-CEC median (below all-CEC median; higher than 47.6% of peers) among 21,677 listed modules. Power density reaches 211.1 W/m2 (1.20 percentage points above 19.91% CEC median). Mid-range 41.0 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 21 panels in series. Alternative peer Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC rates 380.0 W.

Where Does LOF SOLAR CORP LOF-MH62-C380 Fall Across Listed CEC Models?

Distribution marker showing LOF SOLAR CORP LOF-MH62-C380 (380.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where LOF SOLAR CORP LOF-MH62-C380 (380.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLOF SOLAR CORP LOF: 380.0 W

What Dataset Percentiles Define LOF SOLAR CORP LOF-MH62-C380?

Dataset percentiles tracking LOF SOLAR CORP LOF-MH62-C380 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

LOF SOLAR CORP LOF-MH62-C380 Engineering BenchmarksPercentile comparison of LOF SOLAR CORP LOF-MH62-C380 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage380.0 WPTC/STC Retention92.5%Module Efficiency21.11%

What Do the Dataset Ranks Show for LOF SOLAR CORP LOF-MH62-C380?

Benchmark highlights for LOF SOLAR CORP LOF-MH62-C380 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #11,043 / 21,677

380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,929

21.11% Aperture Efficiency

Power density 211.1 W/m2 (1.20 percentage points above 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.64 V at -10 C (593.3 V string) and 46.96 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,360 W STC

Occupies 39.6 m2 (426 sq ft) producing 7,731 W PTC; NEC 690.8 OCPD floor is 17.74 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.0 * (1 + (-0.323/100) * (-10 - 25)) = 45.64 V | OCPD = 1.56 * 11.37 = 17.74 A

Inputs from CEC Modules.csv for LOF SOLAR CORP LOF-MH62-C380: Voc=41.0 V, beta_Voc=-0.323%/C, Isc=11.37 A, STC=380.0 W, Area=1.8 m2.

Result: 13 panels max on 600 V (593.3 V); 22 panels for 8 kW (426 sq ft).

What Are the Published CEC Specifications for LOF SOLAR CORP LOF-MH62-C380?

Official CEC datasheet figures for LOF SOLAR CORP LOF-MH62-C380 (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for LOF SOLAR CORP LOF-MH62-C380.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 380.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 351.4 W (92.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.37 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.9 V / 10.89 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.323 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.11% (1.8 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many LOF SOLAR CORP LOF-MH62-C380 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many LOF SOLAR CORP LOF-MH62-C380 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.08 kW 310 sq ft $1,522 $2,573
8 kW Class 22 8.36 kW 426 sq ft $2,092 $3,538
10 kW Class 27 10.26 kW 523 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This LOF SOLAR CORP Series?

Consolidated LOF SOLAR CORP wattage variants sharing the LOF SOLAR CORP LOF-MH62-C380 mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the LOF SOLAR CORP LOF-MH62-C380 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
LOF SOLAR CORP LOF-MH62-C375 375.0 W 346.7 W 40.85 V 34.75 V 20.83%
LOF SOLAR CORP LOF-MH62-C380 380.0 W 351.4 W 41.0 V 34.9 V 21.11%

How Many LOF SOLAR CORP LOF-MH62-C380 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on LOF SOLAR CORP LOF-MH62-C380 (45.64 V at 14 F).

Computed from Voc=41.0V and beta_Voc=-0.323%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.96 V 12 panels 563.5 V 21 panels
-10 C (14 F) 45.64 V 13 panels 593.3 V 21 panels
0 C (32 F) 44.31 V 13 panels 576.0 V 22 panels
25 C (77 F STC) 41.0 V 14 panels 574.0 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to LOF SOLAR CORP LOF-MH62-C380?

Competing CEC solar panels closest to LOF SOLAR CORP LOF-MH62-C380 in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC
Boviet Solar Technology Co Ltd
380.0 W Tie (0 W) 40.94 V 20.54% 94.2%
DualSun SAS DualSun 380M-120-01
DualSun SAS
380.0 W Tie (0 W) 41.3 V 21.47% 93.9%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W -5.0 W 41.1 V 21.07% 92.6%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W -5.0 W 41.1 V 20.72% 92.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for LOF SOLAR CORP LOF-MH62-C380?

Evaluate LOF SOLAR CORP LOF-MH62-C380 (380.0 W STC, 41.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), LOF SOLAR CORP LOF-MH62-C380 reaches 46.96 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 426 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (426 sq ft).
  • 2026 tax credit baseline: cash residential installs of LOF SOLAR CORP LOF-MH62-C380 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

LOF SOLAR CORP LOF-MH62-C380 8 kW Residential Fit

Needs 22 modules (426 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 351.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for LOF SOLAR CORP LOF-MH62-C380 by LOF SOLAR CORP grounded in CEC test data and NEC 690.7/690.8 limits.

How many LOF SOLAR CORP LOF-MH62-C380 panels fit on a 600 V winter solar string?

At -10 C (14 F), LOF SOLAR CORP LOF-MH62-C380 cold Voc rises from 41.0 V to 45.64 V (beta_Voc -0.323%/C), capping a 600 V string at 13 panels (593.3 V).

How much roof area does an 8 kW array of LOF SOLAR CORP LOF-MH62-C380 need?

An 8 kW DC system uses 22 LOF SOLAR CORP LOF-MH62-C380 modules (8,360 W STC / 7,731 W PTC), covering roughly 426 sq ft and saving ~$2,092/yr at 18.54 c/kWh.

How does LOF SOLAR CORP LOF-MH62-C380 compare against Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC?

LOF SOLAR CORP LOF-MH62-C380 outputs 380.0 W STC (41.0 V Voc, rank #11,043 of 21,677), while Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC delivers 380.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?