LOF SOLAR CORP LOF-MG31-C310 is a 310.0 W STC (283.8 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 18.56% efficiency, 40.1 V Voc at 25 C, and 44.77 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 283.8 W
- Voc @ 25C
- 40.1 V
- Efficiency
- 18.56%
How Does LOF SOLAR CORP LOF-MG31-C310 Compare Against Peer CEC Listings?
Solar engineering breakdown for LOF SOLAR CORP LOF-MG31-C310: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from LOF SOLAR CORP and peers, LOF SOLAR CORP LOF-MG31-C310 stands 100.0 W below the 410.0 W Mono-c-Si median and strong 91.5% PTC-to-STC heat retention (#15,584 of 21,677). Sizing 6 kW (20 panels) to 10 kW (33 panels) yields $1,552-$2,560/yr in baseline US bill offset. Mid-range 40.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does LOF SOLAR CORP LOF-MG31-C310 Fall Across Listed CEC Models?
Distribution marker showing LOF SOLAR CORP LOF-MG31-C310 (310.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define LOF SOLAR CORP LOF-MG31-C310?
Dataset percentiles tracking LOF SOLAR CORP LOF-MG31-C310 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for LOF SOLAR CORP LOF-MG31-C310?
Benchmark highlights for LOF SOLAR CORP LOF-MG31-C310 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.56% Aperture Efficiency
Power density 185.6 W/m2 (1.35 percentage points below 19.91% CEC median). PTC/STC ratio: 91.5% (rank #15,584).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.77 V at -10 C (582.0 V string) and 46.11 V at -20 C (13 max).
26 Panels = 8,060 W STC
Occupies 43.4 m2 (467 sq ft) producing 7,379 W PTC; NEC 690.8 OCPD floor is 15.77 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.1 * (1 + (-0.333/100) * (-10 - 25)) = 44.77 V | OCPD = 1.56 * 10.11 = 15.77 A
Inputs from CEC Modules.csv for LOF SOLAR CORP LOF-MG31-C310: Voc=40.1 V, beta_Voc=-0.333%/C, Isc=10.11 A, STC=310.0 W, Area=1.67 m2.
Result: 13 panels max on 600 V (582.0 V); 26 panels for 8 kW (467 sq ft).
What Are the Published CEC Specifications for LOF SOLAR CORP LOF-MG31-C310?
Official CEC datasheet figures for LOF SOLAR CORP LOF-MG31-C310 (Mono-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 283.8 W (91.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.11 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.5 V / 9.54 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.333 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.56% (1.67 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many LOF SOLAR CORP LOF-MG31-C310 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many LOF SOLAR CORP LOF-MG31-C310 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 360 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 467 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 593 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This LOF SOLAR CORP Series?
Consolidated LOF SOLAR CORP wattage variants sharing the LOF SOLAR CORP LOF-MG31-C310 mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| LOF SOLAR CORP LOF-MG31-C300 | 300.0 W | 274.4 W | 39.8 V | 32.2 V | 17.96% |
| LOF SOLAR CORP LOF-MG31-C305 | 305.0 W | 279.1 W | 39.95 V | 32.35 V | 18.26% |
| LOF SOLAR CORP LOF-MG31-C310 | 310.0 W | 283.8 W | 40.1 V | 32.5 V | 18.56% |
| LOF SOLAR CORP LOF-MG31-C315 | 315.0 W | 288.6 W | 40.25 V | 32.65 V | 18.86% |
| LOF SOLAR CORP LOF-MG31-C320 | 320.0 W | 293.3 W | 40.4 V | 32.8 V | 19.16% |
How Many LOF SOLAR CORP LOF-MG31-C310 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on LOF SOLAR CORP LOF-MG31-C310 (44.77 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.11 V | 13 panels | 599.4 V | 21 panels |
| -10 C (14 F) | 44.77 V | 13 panels | 582.0 V | 22 panels |
| 0 C (32 F) | 43.44 V | 13 panels | 564.7 V | 23 panels |
| 25 C (77 F STC) | 40.1 V | 14 panels | 561.4 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to LOF SOLAR CORP LOF-MG31-C310?
Competing CEC solar panels closest to LOF SOLAR CORP LOF-MG31-C310 in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6610M-310.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6610M-310 Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.05% | 92.2% |
| Boviet Solar Technology Co Ltd BVM6610M-310-H Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.02% | 93.1% |
| Boviet Solar Technology Co Ltd BVM6610M-W5-310-H Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.05% | 93.1% |
| Bluesun Solar Energy Tech CoLtd BSM310M-60 Bluesun Solar Energy Tech CoLtd |
310.0 W | Tie (0 W) | 40.18 V | 19.02% | 91.9% |
What Are the Design Limits and Best-Fit Uses for LOF SOLAR CORP LOF-MG31-C310?
Evaluate LOF SOLAR CORP LOF-MG31-C310 (310.0 W STC, 40.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), LOF SOLAR CORP LOF-MG31-C310 reaches 46.11 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 467 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (467 sq ft).
- 2026 tax credit baseline: cash residential installs of LOF SOLAR CORP LOF-MG31-C310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
LOF SOLAR CORP LOF-MG31-C310 8 kW Residential Fit
Needs 26 modules (467 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6610M-310.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 283.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for LOF SOLAR CORP LOF-MG31-C310 by LOF SOLAR CORP grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for LOF SOLAR CORP LOF-MG31-C310?
Multiplying LOF SOLAR CORP LOF-MG31-C310's 10.11 A short-circuit current by 1.56 equals 15.77 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can LOF SOLAR CORP LOF-MG31-C310 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 44.77 V cold Voc at 14 F and handles 10.11 A Isc; string inverters cap LOF SOLAR CORP LOF-MG31-C310 at 13 panels on 600 V.
Is LOF SOLAR CORP LOF-MG31-C310 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of LOF SOLAR CORP LOF-MG31-C310 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)