Skip to main content
WireAndSun
Calculators
CEC PV Module

LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN — CEC Solar Module Specifications

Manufacturer: LIGHT ENGINE ILUMINACAO SA Registry: CEC Verified Engineering Specification

LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN is a 495.0 W STC (456.8 W PTC) Mono-c-Si solar module ranking #4,591 of 21,677 CEC listings (top 21.5%; higher than 78.5% of peers). It delivers 20.89% efficiency, 45.4 V Voc at 25 C, and 49.45 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
495.0 W
PTC Wattage
456.8 W
Voc @ 25C
45.4 V
Efficiency
20.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN Compare Against Peer CEC Listings?

How LIGHT ENGINE ILUMINACAO SA LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN handles rooftop heat (456.8 W PTC), 8 kW sizing, and cold winter string voltage.

LIGHT ENGINE ILUMINACAO SA builds the LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 208.9 W/m2 (0.98 percentage points above 19.91% CEC median). Compared against Elin Energy (Sirius PV) ELNSM66M-HC-BF-495 (495.0 W), this model holds strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677). Mid-range 45.4 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 21.62 A overcurrent floor served by a 25 A breaker.

Where Does LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN Fall Across Listed CEC Models?

Where LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN (495.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN (495.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLIGHT ENGINE ILUMI: 495.0 W

What Dataset Percentiles Define LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN?

Percentile placement of LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN across power density (208.9 W/m2), thermal retention, and nameplate STC wattage.

LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN Engineering BenchmarksPercentile comparison of LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage495.0 WPTC/STC Retention92.3%Module Efficiency20.89%

What Do the Dataset Ranks Show for LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN?

Four critical engineering numbers homeowners and solar installers check first when reviewing LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN specifications.

Rank #4,591 / 21,677

Top 21.5% STC Output

495.0 W STC (+110.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,901

20.89% Aperture Efficiency

Power density 208.9 W/m2 (0.98 percentage points above 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.45 V at -10 C (593.4 V string) and 50.61 V at -20 C (11 max).

8 kW Reference Array

17 Panels = 8,415 W STC

Occupies 40.3 m2 (434 sq ft) producing 7,766 W PTC; NEC 690.8 OCPD floor is 21.62 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.4 * (1 + (-0.255/100) * (-10 - 25)) = 49.45 V | OCPD = 1.56 * 13.86 = 21.62 A

Inputs from CEC Modules.csv for LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN: Voc=45.4 V, beta_Voc=-0.255%/C, Isc=13.86 A, STC=495.0 W, Area=2.37 m2.

Result: 12 panels max on 600 V (593.4 V); 17 panels for 8 kW (434 sq ft).

What Are the Published CEC Specifications for LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN.

Official California Energy Commission (NREL SAM) test parameters for LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 495.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 456.8 W (92.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.86 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.2 V / 12.96 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.255 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.89% (2.37 m2) Array roof footprint density
Cell Count & Technology 132 cells (Mono-c-Si) Bifacial glass-glass

How Many LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN (495.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.43 kW 332 sq ft $1,609 $2,721
8 kW Class 17 8.41 kW 434 sq ft $2,105 $3,559
10 kW Class 21 10.39 kW 536 sq ft $2,601 $4,397

How Many LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN Modules Fit in a Cold-Weather String?

Maximum series module counts for LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.4V and beta_Voc=-0.255%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.61 V 11 panels 556.7 V 19 panels
-10 C (14 F) 49.45 V 12 panels 593.4 V 20 panels
0 C (32 F) 48.29 V 12 panels 579.5 V 20 panels
25 C (77 F STC) 45.4 V 13 panels 590.2 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN?

Alternative CEC solar modules from competing brands near LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN (495.0 W), including Elin Energy (Sirius PV) ELNSM66M-HC-BF-495.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Elin Energy (Sirius PV) ELNSM66M-HC-BF-495
Elin Energy (Sirius PV)
495.0 W Tie (0 W) 45.45 V 21.02% 94.4%
Aptos Solar Technology LLC DNA-132-BF10-490W
Aptos Solar Technology LLC
490.0 W -5.0 W 45.3 V 20.68% 94.2%
Boviet Solar Technology Co Ltd BVM7610M-485-H-HC-BF
Boviet Solar Technology Co Ltd
485.0 W -10.0 W 44.39 V 22.45% 95.0%
Elin Energy (Sirius PV) ELNSM60M-HC-BF-475
Elin Energy (Sirius PV)
475.0 W -20.0 W 41.82 V 22.09% 94.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN?

Evaluate LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN (495.0 W STC, 45.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN reaches 50.61 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 17 panels for an 8 kW build require 434 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (434 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN 8 kW Residential Fit

Needs 17 modules (434 sq ft) with a 25 A string OCPD, offsetting ~$2,105/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM66M-HC-BF-495.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 456.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN by LIGHT ENGINE ILUMINACAO SA grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN?

Multiplying LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN's 13.86 A short-circuit current by 1.56 equals 21.62 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.45 V cold Voc at 14 F and handles 13.86 A Isc; string inverters cap LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN at 12 panels on 600 V.

Is LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN rely on utility bill offset (~$2,105/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.