LIGHT ENGINE ILUMINACAO SA HS78-600-MN is a 600.0 W STC (565.1 W PTC) Mono-c-Si solar module ranking #1,320 of 21,677 CEC listings (top 6.7%; higher than 93.3% of peers). It delivers 22.06% efficiency, 54.1 V Voc at 25 C, and 59.23 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 600.0 W
- PTC Wattage
- 565.1 W
- Voc @ 25C
- 54.1 V
- Efficiency
- 22.06%
How Does LIGHT ENGINE ILUMINACAO SA HS78-600-MN Compare Against Peer CEC Listings?
How LIGHT ENGINE ILUMINACAO SA LIGHT ENGINE ILUMINACAO SA HS78-600-MN handles rooftop heat (565.1 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, LIGHT ENGINE ILUMINACAO SA HS78-600-MN exhibits 14.1 A short-circuit current, requiring a 22.0 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #1,320 of 21,677 (190.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 38.1 m2 for an 8 kW system (17 panels for 10 kW). Higher 54.1 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does LIGHT ENGINE ILUMINACAO SA HS78-600-MN Fall Across Listed CEC Models?
Where LIGHT ENGINE ILUMINACAO SA HS78-600-MN (600.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define LIGHT ENGINE ILUMINACAO SA HS78-600-MN?
Percentile placement of LIGHT ENGINE ILUMINACAO SA HS78-600-MN across power density (220.6 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for LIGHT ENGINE ILUMINACAO SA HS78-600-MN?
Four critical engineering numbers homeowners and solar installers check first when reviewing LIGHT ENGINE ILUMINACAO SA HS78-600-MN specifications.
Top 6.7% STC Output
600.0 W STC (+215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.06% Aperture Efficiency
Power density 220.6 W/m2 (2.15 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 59.23 V at -10 C (592.3 V string) and 60.7 V at -20 C (9 max).
14 Panels = 8,400 W STC
Occupies 38.1 m2 (410 sq ft) producing 7,911 W PTC; NEC 690.8 OCPD floor is 22.0 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 54.1 * (1 + (-0.271/100) * (-10 - 25)) = 59.23 V | OCPD = 1.56 * 14.1 = 22.0 A
Inputs from CEC Modules.csv for LIGHT ENGINE ILUMINACAO SA HS78-600-MN: Voc=54.1 V, beta_Voc=-0.271%/C, Isc=14.1 A, STC=600.0 W, Area=2.72 m2.
Result: 10 panels max on 600 V (592.3 V); 14 panels for 8 kW (410 sq ft).
What Are the Published CEC Specifications for LIGHT ENGINE ILUMINACAO SA HS78-600-MN?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for LIGHT ENGINE ILUMINACAO SA HS78-600-MN.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 600.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 565.1 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 54.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.1 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.6 V / 13.17 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.06% (2.72 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Monofacial backsheet |
How Many LIGHT ENGINE ILUMINACAO SA HS78-600-MN Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using LIGHT ENGINE ILUMINACAO SA HS78-600-MN (600.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.0 kW | 293 sq ft | $1,502 | $2,539 |
| 8 kW Class | 14 | 8.4 kW | 410 sq ft | $2,102 | $3,555 |
| 10 kW Class | 17 | 10.2 kW | 498 sq ft | $2,553 | $4,317 |
How Many LIGHT ENGINE ILUMINACAO SA HS78-600-MN Modules Fit in a Cold-Weather String?
Maximum series module counts for LIGHT ENGINE ILUMINACAO SA HS78-600-MN from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 60.7 V | 9 panels | 546.3 V | 16 panels |
| -10 C (14 F) | 59.23 V | 10 panels | 592.3 V | 16 panels |
| 0 C (32 F) | 57.77 V | 10 panels | 577.7 V | 17 panels |
| 25 C (77 F STC) | 54.1 V | 11 panels | 595.1 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to LIGHT ENGINE ILUMINACAO SA HS78-600-MN?
Alternative CEC solar modules from competing brands near LIGHT ENGINE ILUMINACAO SA HS78-600-MN (600.0 W), including Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE78-18X-600.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE78-18X-600 Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd |
600.0 W | Tie (0 W) | 54.09 V | 21.43% | 93.2% |
| Hengdian Group DMEGC Magnetics Co Ltd DM600M10T-B72yyy Hengdian Group DMEGC Magnetics Co Ltd |
600.0 W | Tie (0 W) | 53.3 V | 23.26% | 94.1% |
| G-Star Pte Ltd GSD7G78M-605BT G-Star Pte Ltd |
605.0 W | +5.0 W | 54.29 V | 21.84% | 94.4% |
| G-Star Pte Ltd GSD7G78M-605WT G-Star Pte Ltd |
605.0 W | +5.0 W | 54.29 V | 21.84% | 94.4% |
What Are the Design Limits and Best-Fit Uses for LIGHT ENGINE ILUMINACAO SA HS78-600-MN?
Evaluate LIGHT ENGINE ILUMINACAO SA HS78-600-MN (600.0 W STC, 54.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), LIGHT ENGINE ILUMINACAO SA HS78-600-MN reaches 60.7 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 410 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of LIGHT ENGINE ILUMINACAO SA HS78-600-MN carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
LIGHT ENGINE ILUMINACAO SA HS78-600-MN 8 kW Residential Fit
Needs 14 modules (410 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 9 panels (-20 C), or compare Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE78-18X-600.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 565.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for LIGHT ENGINE ILUMINACAO SA HS78-600-MN by LIGHT ENGINE ILUMINACAO SA grounded in CEC test data and NEC 690.7/690.8 limits.
Why is LIGHT ENGINE ILUMINACAO SA HS78-600-MN PTC wattage (565.1 W) lower than STC (600.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 565.1 W PTC (94.2% retention) across LIGHT ENGINE ILUMINACAO SA HS78-600-MN's 2.72 m2 aperture.
Who should skip LIGHT ENGINE ILUMINACAO SA HS78-600-MN on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 LIGHT ENGINE ILUMINACAO SA HS78-600-MN panels (410 sq ft) leave unusable roof gaps vs. Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE78-18X-600.
What is the 1,000 V commercial string limit for LIGHT ENGINE ILUMINACAO SA HS78-600-MN?
On 1,000 V commercial inverters at -10 C (59.23 V cold Voc), LIGHT ENGINE ILUMINACAO SA HS78-600-MN fits up to 16 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)