Jinko Solar Co Ltd JKM360M-66H is a 360.0 W STC (333.4 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 20.34% efficiency, 43.58 V Voc at 25 C, and 48.37 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 360.0 W
- PTC Wattage
- 333.4 W
- Voc @ 25C
- 43.58 V
- Efficiency
- 20.34%
How Does Jinko Solar Co Ltd JKM360M-66H Compare Against Peer CEC Listings?
Solar engineering breakdown for Jinko Solar Co Ltd JKM360M-66H: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Jinko Solar Co Ltd and peers, Jinko Solar Co Ltd JKM360M-66H stands 50.0 W below the 410.0 W Mono-c-Si median and strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677). Sizing 6 kW (17 panels) to 10 kW (28 panels) yields $1,532-$2,523/yr in baseline US bill offset. Mid-range 43.58 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does Jinko Solar Co Ltd JKM360M-66H Fall Across Listed CEC Models?
Distribution marker showing Jinko Solar Co Ltd JKM360M-66H (360.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Jinko Solar Co Ltd JKM360M-66H?
Dataset percentiles tracking Jinko Solar Co Ltd JKM360M-66H power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM360M-66H?
Benchmark highlights for Jinko Solar Co Ltd JKM360M-66H covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
360.0 W STC · Higher Than 41.3%
360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.34% Aperture Efficiency
Power density 203.4 W/m2 (0.43 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 48.37 V at -10 C (580.4 V string) and 49.74 V at -20 C (12 max).
23 Panels = 8,280 W STC
Occupies 40.7 m2 (438 sq ft) producing 7,668 W PTC; NEC 690.8 OCPD floor is 16.35 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 43.58 * (1 + (-0.314/100) * (-10 - 25)) = 48.37 V | OCPD = 1.56 * 10.48 = 16.35 A
Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM360M-66H: Voc=43.58 V, beta_Voc=-0.314%/C, Isc=10.48 A, STC=360.0 W, Area=1.77 m2.
Result: 12 panels max on 600 V (580.4 V); 23 panels for 8 kW (438 sq ft).
What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM360M-66H?
Official CEC datasheet figures for Jinko Solar Co Ltd JKM360M-66H (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 333.4 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 43.58 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.48 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.97 V / 9.74 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.314 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.34% (1.77 m2) | Array roof footprint density |
| Cell Count & Technology | 22 cells (Mono-c-Si) | Monofacial backsheet |
How Many Jinko Solar Co Ltd JKM360M-66H Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Jinko Solar Co Ltd JKM360M-66H modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.12 kW | 324 sq ft | $1,532 | $2,590 |
| 8 kW Class | 23 | 8.28 kW | 438 sq ft | $2,072 | $3,504 |
| 10 kW Class | 28 | 10.08 kW | 533 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?
Consolidated Jinko Solar Co Ltd wattage variants sharing the Jinko Solar Co Ltd JKM360M-66H mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jinko Solar Co Ltd JKM350M-66H | 350.0 W | 323.9 W | 43.41 V | 36.77 V | 19.77% |
| Jinko Solar Co Ltd JKM355M-66H | 355.0 W | 328.6 W | 43.49 V | 36.87 V | 20.06% |
| Jinko Solar Co Ltd JKM360M-66H | 360.0 W | 333.4 W | 43.58 V | 36.97 V | 20.34% |
| Jinko Solar Co Ltd JKM365M-66H | 365.0 W | 338.2 W | 43.66 V | 37.06 V | 20.62% |
| Jinko Solar Co Ltd JKM370M-66H | 370.0 W | 342.9 W | 43.75 V | 37.15 V | 20.9% |
How Many Jinko Solar Co Ltd JKM360M-66H Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Jinko Solar Co Ltd JKM360M-66H (48.37 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 49.74 V | 12 panels | 596.9 V | 20 panels |
| -10 C (14 F) | 48.37 V | 12 panels | 580.4 V | 20 panels |
| 0 C (32 F) | 47.0 V | 12 panels | 564.0 V | 21 panels |
| 25 C (77 F STC) | 43.58 V | 13 panels | 566.5 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM360M-66H?
Competing CEC solar panels closest to Jinko Solar Co Ltd JKM360M-66H in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS6XH-360M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6XH-360M CSI Solar Co Ltd |
360.0 W | Tie (0 W) | 45.0 V | 19.46% | 92.8% |
| DualSun SAS DualSun 360M-120-00 DualSun SAS |
360.0 W | Tie (0 W) | 40.9 V | 19.89% | 93.3% |
| DualSun SAS DualSun 360M-120-01 DualSun SAS |
360.0 W | Tie (0 W) | 40.9 V | 19.89% | 93.2% |
| CSI Solar Co Ltd CS3L-360P CSI Solar Co Ltd |
360.0 W | Tie (0 W) | 40.6 V | 20.11% | 92.4% |
What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM360M-66H?
Evaluate Jinko Solar Co Ltd JKM360M-66H (360.0 W STC, 43.58 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM360M-66H reaches 49.74 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 438 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (438 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM360M-66H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jinko Solar Co Ltd JKM360M-66H 8 kW Residential Fit
Needs 23 modules (438 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS6XH-360M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 333.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jinko Solar Co Ltd JKM360M-66H by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Jinko Solar Co Ltd JKM360M-66H?
Multiplying Jinko Solar Co Ltd JKM360M-66H's 10.48 A short-circuit current by 1.56 equals 16.35 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Jinko Solar Co Ltd JKM360M-66H pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 48.37 V cold Voc at 14 F and handles 10.48 A Isc; string inverters cap Jinko Solar Co Ltd JKM360M-66H at 12 panels on 600 V.
Is Jinko Solar Co Ltd JKM360M-66H eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jinko Solar Co Ltd JKM360M-66H rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)