Jinko Solar Co Ltd JKM235P-60B is a 235.0 W STC (210.8 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.36% efficiency, 37.2 V Voc at 25 C, and 41.7 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 235.0 W
- PTC Wattage
- 210.8 W
- Voc @ 25C
- 37.2 V
- Efficiency
- 14.36%
How Does Jinko Solar Co Ltd JKM235P-60B Compare Against Peer CEC Listings?
Solar engineering breakdown for Jinko Solar Co Ltd JKM235P-60B: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from Jinko Solar Co Ltd and peers, Jinko Solar Co Ltd JKM235P-60B stands 43.8 W below the 278.8 W Multi-c-Si median and typical 89.7% PTC-to-STC thermal output (210.8 W real-world rating). Sizing 6 kW (26 panels) to 10 kW (43 panels) yields $1,529-$2,530/yr in baseline US bill offset. Lower 37.2 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Jinko Solar Co Ltd JKM235P-60B Fall Across Listed CEC Models?
Distribution marker showing Jinko Solar Co Ltd JKM235P-60B (235.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Jinko Solar Co Ltd JKM235P-60B?
Dataset percentiles tracking Jinko Solar Co Ltd JKM235P-60B power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM235P-60B?
Benchmark highlights for Jinko Solar Co Ltd JKM235P-60B covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
235.0 W STC · Higher Than 5.4%
235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.36% Aperture Efficiency
Power density 143.6 W/m2 (5.55 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.7 V at -10 C (583.8 V string) and 42.99 V at -20 C (13 max).
35 Panels = 8,225 W STC
Occupies 57.3 m2 (617 sq ft) producing 7,378 W PTC; NEC 690.8 OCPD floor is 13.15 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.2 * (1 + (-0.346/100) * (-10 - 25)) = 41.7 V | OCPD = 1.56 * 8.43 = 13.15 A
Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM235P-60B: Voc=37.2 V, beta_Voc=-0.346%/C, Isc=8.43 A, STC=235.0 W, Area=1.637 m2.
Result: 14 panels max on 600 V (583.8 V); 35 panels for 8 kW (617 sq ft).
What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM235P-60B?
Official CEC datasheet figures for Jinko Solar Co Ltd JKM235P-60B (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 235.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 210.8 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.43 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.0 V / 7.84 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.346 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.36% (1.637 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Jinko Solar Co Ltd JKM235P-60B Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Jinko Solar Co Ltd JKM235P-60B modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 26 | 6.11 kW | 458 sq ft | $1,529 | $2,586 |
| 8 kW Class | 35 | 8.22 kW | 617 sq ft | $2,057 | $3,479 |
| 10 kW Class | 43 | 10.11 kW | 758 sq ft | $2,530 | $4,279 |
Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?
Consolidated Jinko Solar Co Ltd wattage variants sharing the Jinko Solar Co Ltd JKM235P-60B mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jinko Solar Co Ltd JKM225P-60B | 225.0 W | 201.6 W | 36.9 V | 29.6 V | 13.75% |
| Jinko Solar Co Ltd JKM230P-60B | 230.0 W | 206.2 W | 37.0 V | 29.8 V | 14.05% |
| Jinko Solar Co Ltd JKM235P-60B | 235.0 W | 210.8 W | 37.2 V | 30.0 V | 14.36% |
| Jinko Solar Co Ltd JKM240P-60B | 240.0 W | 215.4 W | 37.4 V | 30.2 V | 14.66% |
| Jinko Solar Co Ltd JKM245P-60B | 245.0 W | 221.5 W | 37.5 V | 30.1 V | 14.97% |
How Many Jinko Solar Co Ltd JKM235P-60B Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Jinko Solar Co Ltd JKM235P-60B (41.7 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.99 V | 13 panels | 558.9 V | 23 panels |
| -10 C (14 F) | 41.7 V | 14 panels | 583.8 V | 23 panels |
| 0 C (32 F) | 40.42 V | 14 panels | 565.9 V | 24 panels |
| 25 C (77 F STC) | 37.2 V | 16 panels | 595.2 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM235P-60B?
Competing CEC solar panels closest to Jinko Solar Co Ltd JKM235P-60B in nameplate wattage and Voc, starting with AXITEC AC-235P/156-60S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-235P/156-60S AXITEC |
235.0 W | Tie (0 W) | 37.16 V | 14.48% | 90.0% |
| Gintech Energy GTE 235M Gintech Energy |
235.0 W | Tie (0 W) | 37.32 V | 13.97% | 89.5% |
| APOS Energy AS235 APOS Energy |
235.0 W | Tie (0 W) | 37.34 V | 14.17% | 89.7% |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q Hanwha Qcells (Qidong) Co Ltd |
235.0 W | Tie (0 W) | 37.0 V | 14.54% | 89.0% |
What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM235P-60B?
Evaluate Jinko Solar Co Ltd JKM235P-60B (235.0 W STC, 37.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM235P-60B reaches 42.99 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 617 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (617 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM235P-60B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jinko Solar Co Ltd JKM235P-60B 8 kW Residential Fit
Needs 35 modules (617 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-235P/156-60S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 210.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jinko Solar Co Ltd JKM235P-60B by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Jinko Solar Co Ltd JKM235P-60B?
Multiplying Jinko Solar Co Ltd JKM235P-60B's 8.43 A short-circuit current by 1.56 equals 13.15 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Jinko Solar Co Ltd JKM235P-60B pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 41.7 V cold Voc at 14 F and handles 8.43 A Isc; string inverters cap Jinko Solar Co Ltd JKM235P-60B at 14 panels on 600 V.
Is Jinko Solar Co Ltd JKM235P-60B eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jinko Solar Co Ltd JKM235P-60B rely on utility bill offset (~$2,057/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)