Skip to main content
WireAndSun
Calculators
CEC PV Module

JA Solar JAP72S01-335/SC — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP72S01-335/SC is a 335.0 W STC (309.0 W PTC) Multi-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 17.78% efficiency, 46.7 V Voc at 25 C, and 51.54 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
335.0 W
PTC Wattage
309.0 W
Voc @ 25C
46.7 V
Efficiency
17.78%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP72S01-335/SC Compare Against Peer CEC Listings?

How JA Solar JA Solar JAP72S01-335/SC handles rooftop heat (309.0 W PTC), 8 kW sizing, and cold winter string voltage.

JA Solar builds the JA Solar JAP72S01-335/SC (Multi-c-Si) as a compact residential or specialty off-grid module delivering 177.8 W/m2 (2.13 percentage points below 19.91% CEC median). Compared against Centrosolar America EM72 335BW (335.0 W), this model holds strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677). Mid-range 46.7 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 14.59 A overcurrent floor served by a 15 A breaker.

Where Does JA Solar JAP72S01-335/SC Fall Across Listed CEC Models?

Where JA Solar JAP72S01-335/SC (335.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP72S01-335/SC (335.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP72S01-: 335.0 W

What Dataset Percentiles Define JA Solar JAP72S01-335/SC?

Percentile placement of JA Solar JAP72S01-335/SC across power density (177.8 W/m2), thermal retention, and nameplate STC wattage.

JA Solar JAP72S01-335/SC Engineering BenchmarksPercentile comparison of JA Solar JAP72S01-335/SC wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage335.0 WPTC/STC Retention92.2%Module Efficiency17.78%

What Do the Dataset Ranks Show for JA Solar JAP72S01-335/SC?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAP72S01-335/SC specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #13,844 / 21,677

335.0 W STC · Higher Than 34.7%

335.0 W STC (-50.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #15,390

17.78% Aperture Efficiency

Power density 177.8 W/m2 (2.13 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.54 V at -10 C (566.9 V string) and 52.92 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,040 W STC

Occupies 45.2 m2 (487 sq ft) producing 7,416 W PTC; NEC 690.8 OCPD floor is 14.59 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.7 * (1 + (-0.296/100) * (-10 - 25)) = 51.54 V | OCPD = 1.56 * 9.35 = 14.59 A

Inputs from CEC Modules.csv for JA Solar JAP72S01-335/SC: Voc=46.7 V, beta_Voc=-0.296%/C, Isc=9.35 A, STC=335.0 W, Area=1.884 m2.

Result: 11 panels max on 600 V (566.9 V); 24 panels for 8 kW (487 sq ft).

What Are the Published CEC Specifications for JA Solar JAP72S01-335/SC?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAP72S01-335/SC.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP72S01-335/SC.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 335.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 309.0 W (92.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.83 V / 8.87 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.296 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.78% (1.884 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP72S01-335/SC Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAP72S01-335/SC (335.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.03 kW 365 sq ft $1,509 $2,552
8 kW Class 24 8.04 kW 487 sq ft $2,012 $3,403
10 kW Class 30 10.05 kW 608 sq ft $2,515 $4,253

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAP72S01-335/SC architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the JA Solar JAP72S01-335/SC wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAP72S01-325/SC 325.0 W 300.1 W 46.38 V 37.39 V 17.29%
JA Solar JAP72S01-330/SC 330.0 W 304.2 W 46.4 V 37.65 V 17.52%
JA Solar JAP72S01-335/SC 335.0 W 309.0 W 46.7 V 37.83 V 17.78%
JA Solar JAP72S01-340/SC 340.0 W 313.7 W 47.0 V 38.02 V 18.05%

How Many JA Solar JAP72S01-335/SC Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAP72S01-335/SC from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=46.7V and beta_Voc=-0.296%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.92 V 11 panels 582.1 V 18 panels
-10 C (14 F) 51.54 V 11 panels 566.9 V 19 panels
0 C (32 F) 50.16 V 11 panels 551.8 V 19 panels
25 C (77 F STC) 46.7 V 12 panels 560.4 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP72S01-335/SC?

Alternative CEC solar modules from competing brands near JA Solar JAP72S01-335/SC (335.0 W), including Centrosolar America EM72 335BW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America EM72 335BW
Centrosolar America
335.0 W Tie (0 W) 46.75 V 17.42% 91.4%
Centrosolar America EM72 335SW
Centrosolar America
335.0 W Tie (0 W) 46.75 V 17.42% 91.4%
Bluesun Solar Energy Tech CoLtd BSM335P-72
Bluesun Solar Energy Tech CoLtd
335.0 W Tie (0 W) 46.76 V 17.29% 91.4%
AXITEC AC-335P/72X
AXITEC
335.0 W Tie (0 W) 46.45 V 17.36% 90.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP72S01-335/SC?

Evaluate JA Solar JAP72S01-335/SC (335.0 W STC, 46.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP72S01-335/SC reaches 52.92 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 487 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (487 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP72S01-335/SC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP72S01-335/SC 8 kW Residential Fit

Needs 24 modules (487 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America EM72 335BW.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 309.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP72S01-335/SC by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for JA Solar JAP72S01-335/SC?

Multiplying JA Solar JAP72S01-335/SC's 9.35 A short-circuit current by 1.56 equals 14.59 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can JA Solar JAP72S01-335/SC pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.54 V cold Voc at 14 F and handles 9.35 A Isc; string inverters cap JA Solar JAP72S01-335/SC at 11 panels on 600 V.

Is JA Solar JAP72S01-335/SC eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAP72S01-335/SC rely on utility bill offset (~$2,012/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.