Skip to main content
WireAndSun
Calculators
CEC PV Module

AXITEC AC-335P/72X — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-335P/72X is a 335.0 W STC (304.2 W PTC) Multi-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 17.36% efficiency, 46.45 V Voc at 25 C, and 51.65 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
335.0 W
PTC Wattage
304.2 W
Voc @ 25C
46.45 V
Efficiency
17.36%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-335P/72X Compare Against Peer CEC Listings?

How AXITEC AXITEC AC-335P/72X handles rooftop heat (304.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, AXITEC AC-335P/72X exhibits 9.3 A short-circuit current, requiring a 14.51 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #13,844 of 21,677 (56.2 W above the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 46.3 m2 for an 8 kW system (30 panels for 10 kW). Mid-range 46.45 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does AXITEC AC-335P/72X Fall Across Listed CEC Models?

Where AXITEC AC-335P/72X (335.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-335P/72X (335.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-335P/72X: 335.0 W

What Dataset Percentiles Define AXITEC AC-335P/72X?

Percentile placement of AXITEC AC-335P/72X across power density (173.6 W/m2), thermal retention, and nameplate STC wattage.

AXITEC AC-335P/72X Engineering BenchmarksPercentile comparison of AXITEC AC-335P/72X wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage335.0 WPTC/STC Retention90.8%Module Efficiency17.36%

What Do the Dataset Ranks Show for AXITEC AC-335P/72X?

Four critical engineering numbers homeowners and solar installers check first when reviewing AXITEC AC-335P/72X specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #13,844 / 21,677

335.0 W STC · Higher Than 34.7%

335.0 W STC (-50.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #15,987

17.36% Aperture Efficiency

Power density 173.6 W/m2 (2.55 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.65 V at -10 C (568.1 V string) and 53.14 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,040 W STC

Occupies 46.3 m2 (499 sq ft) producing 7,301 W PTC; NEC 690.8 OCPD floor is 14.51 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.45 * (1 + (-0.32/100) * (-10 - 25)) = 51.65 V | OCPD = 1.56 * 9.3 = 14.51 A

Inputs from CEC Modules.csv for AXITEC AC-335P/72X: Voc=46.45 V, beta_Voc=-0.32%/C, Isc=9.3 A, STC=335.0 W, Area=1.93 m2.

Result: 11 panels max on 600 V (568.1 V); 24 panels for 8 kW (499 sq ft).

What Are the Published CEC Specifications for AXITEC AC-335P/72X?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for AXITEC AC-335P/72X.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-335P/72X.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 335.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 304.2 W (90.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.45 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.3 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.98 V / 8.82 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.32 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.36% (1.93 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many AXITEC AC-335P/72X Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using AXITEC AC-335P/72X (335.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.03 kW 374 sq ft $1,509 $2,552
8 kW Class 24 8.04 kW 499 sq ft $2,012 $3,403
10 kW Class 30 10.05 kW 623 sq ft $2,515 $4,253

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

All closely matched AXITEC wattages and cosmetic trims sharing the AXITEC AC-335P/72X architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the AXITEC AC-335P/72X wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-325P/72X 325.0 W 294.9 W 45.92 V 37.66 V 16.84%
AXITEC AC-330P/72X 330.0 W 299.5 W 45.97 V 37.8 V 17.1%
AXITEC AC-335P/72X 335.0 W 304.2 W 46.45 V 37.98 V 17.36%
AXITEC AC-340P/72X 340.0 W 308.9 W 46.61 V 38.16 V 17.62%
AXITEC AC-345P/72X 345.0 W 313.6 W 46.76 V 38.42 V 17.88%

How Many AXITEC AC-335P/72X Modules Fit in a Cold-Weather String?

Maximum series module counts for AXITEC AC-335P/72X from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=46.45V and beta_Voc=-0.32%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.14 V 11 panels 584.5 V 18 panels
-10 C (14 F) 51.65 V 11 panels 568.1 V 19 panels
0 C (32 F) 50.17 V 11 panels 551.9 V 19 panels
25 C (77 F STC) 46.45 V 12 panels 557.4 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-335P/72X?

Alternative CEC solar modules from competing brands near AXITEC AC-335P/72X (335.0 W), including Boviet Solar Technology Co Ltd BVM6612M-335.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-335
Boviet Solar Technology Co Ltd
335.0 W Tie (0 W) 46.4 V 17.27% 91.7%
GCL System Integration Technology Co Ltd GCL-M6/72335
GCL System Integration Technology Co Ltd
335.0 W Tie (0 W) 46.4 V 17.27% 90.4%
GCL System Integration Technology Co Ltd GCL-P6/72335
GCL System Integration Technology Co Ltd
335.0 W Tie (0 W) 46.4 V 17.27% 90.8%
GCL System Integration Technology Co Ltd GCL-P6/72B335
GCL System Integration Technology Co Ltd
335.0 W Tie (0 W) 46.4 V 17.27% 90.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-335P/72X?

Evaluate AXITEC AC-335P/72X (335.0 W STC, 46.45 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-335P/72X reaches 53.14 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 499 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (499 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-335P/72X carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-335P/72X 8 kW Residential Fit

Needs 24 modules (499 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-335.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 304.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-335P/72X by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

Why is AXITEC AC-335P/72X PTC wattage (304.2 W) lower than STC (335.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 304.2 W PTC (90.8% retention) across AXITEC AC-335P/72X's 1.93 m2 aperture.

Who should skip AXITEC AC-335P/72X on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 AXITEC AC-335P/72X panels (499 sq ft) leave unusable roof gaps vs. Boviet Solar Technology Co Ltd BVM6612M-335.

What is the 1,000 V commercial string limit for AXITEC AC-335P/72X?

On 1,000 V commercial inverters at -10 C (51.65 V cold Voc), AXITEC AC-335P/72X fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AXITEC AC-335P/72X.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.