Skip to main content
WireAndSun
Calculators
CEC PV Module

JA Solar JAP6(BK)-72-300 — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP6(BK)-72-300 is a 300.0 W STC (267.5 W PTC) Multi-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 15.48% efficiency, 44.6 V Voc at 25 C, and 50.28 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
300.0 W
PTC Wattage
267.5 W
Voc @ 25C
44.6 V
Efficiency
15.48%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP6(BK)-72-300 Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAP6(BK)-72-300: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from JA Solar and peers, JA Solar JAP6(BK)-72-300 stands 21.2 W above the 278.8 W Multi-c-Si median and typical 89.2% PTC-to-STC thermal output (267.5 W real-world rating). Sizing 6 kW (20 panels) to 10 kW (34 panels) yields $1,502-$2,553/yr in baseline US bill offset. Mid-range 44.6 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does JA Solar JAP6(BK)-72-300 Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAP6(BK)-72-300 (300.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP6(BK)-72-300 (300.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP6(BK)-: 300.0 W

What Dataset Percentiles Define JA Solar JAP6(BK)-72-300?

Dataset percentiles tracking JA Solar JAP6(BK)-72-300 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

JA Solar JAP6(BK)-72-300 Engineering BenchmarksPercentile comparison of JA Solar JAP6(BK)-72-300 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage300.0 WPTC/STC Retention89.2%Module Efficiency15.48%

What Do the Dataset Ranks Show for JA Solar JAP6(BK)-72-300?

Benchmark highlights for JA Solar JAP6(BK)-72-300 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #16,498 / 21,677

300.0 W STC · Higher Than 22.1%

300.0 W STC (-85.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,946

15.48% Aperture Efficiency

Power density 154.8 W/m2 (4.43 percentage points below 19.91% CEC median). PTC/STC ratio: 89.2% (rank #20,311).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.28 V at -10 C (553.1 V string) and 51.91 V at -20 C (11 max).

8 kW Reference Array

27 Panels = 8,100 W STC

Occupies 52.3 m2 (563 sq ft) producing 7,222 W PTC; NEC 690.8 OCPD floor is 13.31 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.6 * (1 + (-0.364/100) * (-10 - 25)) = 50.28 V | OCPD = 1.56 * 8.53 = 13.31 A

Inputs from CEC Modules.csv for JA Solar JAP6(BK)-72-300: Voc=44.6 V, beta_Voc=-0.364%/C, Isc=8.53 A, STC=300.0 W, Area=1.938 m2.

Result: 11 panels max on 600 V (553.1 V); 27 panels for 8 kW (563 sq ft).

What Are the Published CEC Specifications for JA Solar JAP6(BK)-72-300?

Official CEC datasheet figures for JA Solar JAP6(BK)-72-300 (Multi-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6(BK)-72-300.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 300.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 267.5 W (89.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.53 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.17 V / 7.83 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.364 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.48% (1.938 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP6(BK)-72-300 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAP6(BK)-72-300 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.0 kW 417 sq ft $1,502 $2,539
8 kW Class 27 8.1 kW 563 sq ft $2,027 $3,428
10 kW Class 34 10.2 kW 709 sq ft $2,553 $4,317

How Many JA Solar JAP6(BK)-72-300 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAP6(BK)-72-300 (50.28 V at 14 F).

Computed from Voc=44.6V and beta_Voc=-0.364%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.91 V 11 panels 571.0 V 19 panels
-10 C (14 F) 50.28 V 11 panels 553.1 V 19 panels
0 C (32 F) 48.66 V 12 panels 583.9 V 20 panels
25 C (77 F STC) 44.6 V 13 panels 579.8 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6(BK)-72-300?

Competing CEC solar panels closest to JA Solar JAP6(BK)-72-300 in nameplate wattage and Voc, starting with Auxin Solar AXN6P612T305G.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6P612T305G
Auxin Solar
305.0 W +5.0 W 45.0 V 15.63% 90.3%
Anhui Rinengzhongtian Semiconductor Development QJM310-72
Anhui Rinengzhongtian Semiconductor Development
310.0 W +10.0 W 44.65 V 15.98% 90.0%
Anhui Rinengzhongtian Semiconductor Development QJP310-72
Anhui Rinengzhongtian Semiconductor Development
310.0 W +10.0 W 44.65 V 15.98% 90.6%
CSI Solar Co Ltd CS6X-310P
CSI Solar Co Ltd
310.0 W +10.0 W 44.9 V 16.31% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP6(BK)-72-300?

Evaluate JA Solar JAP6(BK)-72-300 (300.0 W STC, 44.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6(BK)-72-300 reaches 51.91 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 27 panels for an 8 kW build require 563 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (563 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP6(BK)-72-300 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP6(BK)-72-300 8 kW Residential Fit

Needs 27 modules (563 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 267.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6(BK)-72-300 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for JA Solar JAP6(BK)-72-300?

Multiplying JA Solar JAP6(BK)-72-300's 8.53 A short-circuit current by 1.56 equals 13.31 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can JA Solar JAP6(BK)-72-300 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.28 V cold Voc at 14 F and handles 8.53 A Isc; string inverters cap JA Solar JAP6(BK)-72-300 at 11 panels on 600 V.

Is JA Solar JAP6(BK)-72-300 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAP6(BK)-72-300 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.