Skip to main content
WireAndSun
Calculators
CEC PV Module

JA Solar JAP6(BK)-72-270 — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP6(BK)-72-270 is a 270.0 W STC (240.1 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 13.93% efficiency, 44.0 V Voc at 25 C, and 49.61 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
270.0 W
PTC Wattage
240.1 W
Voc @ 25C
44.0 V
Efficiency
13.93%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP6(BK)-72-270 Compare Against Peer CEC Listings?

How JA Solar JA Solar JAP6(BK)-72-270 handles rooftop heat (240.1 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, JA Solar JAP6(BK)-72-270 exhibits 8.2 A short-circuit current, requiring a 12.79 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #18,572 of 21,677 (8.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 58.1 m2 for an 8 kW system (38 panels for 10 kW). Mid-range 44.0 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does JA Solar JAP6(BK)-72-270 Fall Across Listed CEC Models?

Where JA Solar JAP6(BK)-72-270 (270.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP6(BK)-72-270 (270.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP6(BK)-: 270.0 W

What Dataset Percentiles Define JA Solar JAP6(BK)-72-270?

Percentile placement of JA Solar JAP6(BK)-72-270 across power density (139.3 W/m2), thermal retention, and nameplate STC wattage.

JA Solar JAP6(BK)-72-270 Engineering BenchmarksPercentile comparison of JA Solar JAP6(BK)-72-270 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage270.0 WPTC/STC Retention88.9%Module Efficiency13.93%

What Do the Dataset Ranks Show for JA Solar JAP6(BK)-72-270?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAP6(BK)-72-270 specifications.

Rank #18,572 / 21,677

270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,942

13.93% Aperture Efficiency

Power density 139.3 W/m2 (5.98 percentage points below 19.91% CEC median). PTC/STC ratio: 88.9% (rank #20,819).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.61 V at -10 C (595.3 V string) and 51.21 V at -20 C (11 max).

8 kW Reference Array

30 Panels = 8,100 W STC

Occupies 58.1 m2 (626 sq ft) producing 7,203 W PTC; NEC 690.8 OCPD floor is 12.79 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.0 * (1 + (-0.364/100) * (-10 - 25)) = 49.61 V | OCPD = 1.56 * 8.2 = 12.79 A

Inputs from CEC Modules.csv for JA Solar JAP6(BK)-72-270: Voc=44.0 V, beta_Voc=-0.364%/C, Isc=8.2 A, STC=270.0 W, Area=1.938 m2.

Result: 12 panels max on 600 V (595.3 V); 30 panels for 8 kW (626 sq ft).

What Are the Published CEC Specifications for JA Solar JAP6(BK)-72-270?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAP6(BK)-72-270.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6(BK)-72-270.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 270.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 240.1 W (88.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.2 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.0 V / 7.5 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.364 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.93% (1.938 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP6(BK)-72-270 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAP6(BK)-72-270 (270.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.21 kW 480 sq ft $1,554 $2,628
8 kW Class 30 8.1 kW 626 sq ft $2,027 $3,428
10 kW Class 38 10.26 kW 793 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAP6(BK)-72-270 architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the JA Solar JAP6(BK)-72-270 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAP6(BK)-72-265 265.0 W 235.5 W 44.0 V 35.96 V 13.67%
JA Solar JAP6(BK)-72-270 270.0 W 240.1 W 44.0 V 36.0 V 13.93%

How Many JA Solar JAP6(BK)-72-270 Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAP6(BK)-72-270 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=44.0V and beta_Voc=-0.364%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.21 V 11 panels 563.3 V 19 panels
-10 C (14 F) 49.61 V 12 panels 595.3 V 20 panels
0 C (32 F) 48.0 V 12 panels 576.0 V 20 panels
25 C (77 F STC) 44.0 V 13 panels 572.0 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6(BK)-72-270?

Alternative CEC solar modules from competing brands near JA Solar JAP6(BK)-72-270 (270.0 W), including Centrosolar America DP72 270.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DP72 270
Centrosolar America
270.0 W Tie (0 W) 43.85 V 13.89% 88.4%
AXITEC AC-270P/156-72S
AXITEC
270.0 W Tie (0 W) 44.18 V 13.94% 89.9%
Anhui Rinengzhongtian Semiconductor Development QJM270-72
Anhui Rinengzhongtian Semiconductor Development
270.0 W Tie (0 W) 43.67 V 13.92% 89.6%
Advance Power API-M270
Advance Power
270.0 W Tie (0 W) 44.64 V 13.84% 89.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP6(BK)-72-270?

Evaluate JA Solar JAP6(BK)-72-270 (270.0 W STC, 44.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6(BK)-72-270 reaches 51.21 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 626 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (626 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP6(BK)-72-270 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP6(BK)-72-270 8 kW Residential Fit

Needs 30 modules (626 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DP72 270.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 240.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6(BK)-72-270 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is JA Solar JAP6(BK)-72-270 PTC wattage (240.1 W) lower than STC (270.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 240.1 W PTC (88.9% retention) across JA Solar JAP6(BK)-72-270's 1.938 m2 aperture.

Who should skip JA Solar JAP6(BK)-72-270 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 30 JA Solar JAP6(BK)-72-270 panels (626 sq ft) leave unusable roof gaps vs. Centrosolar America DP72 270.

What is the 1,000 V commercial string limit for JA Solar JAP6(BK)-72-270?

On 1,000 V commercial inverters at -10 C (49.61 V cold Voc), JA Solar JAP6(BK)-72-270 fits up to 20 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.