JA Solar JAP6(BK)-72-270 is a 270.0 W STC (240.1 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 13.93% efficiency, 44.0 V Voc at 25 C, and 49.61 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 270.0 W
- PTC Wattage
- 240.1 W
- Voc @ 25C
- 44.0 V
- Efficiency
- 13.93%
How Does JA Solar JAP6(BK)-72-270 Compare Against Peer CEC Listings?
How JA Solar JA Solar JAP6(BK)-72-270 handles rooftop heat (240.1 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, JA Solar JAP6(BK)-72-270 exhibits 8.2 A short-circuit current, requiring a 12.79 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #18,572 of 21,677 (8.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 58.1 m2 for an 8 kW system (38 panels for 10 kW). Mid-range 44.0 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does JA Solar JAP6(BK)-72-270 Fall Across Listed CEC Models?
Where JA Solar JAP6(BK)-72-270 (270.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define JA Solar JAP6(BK)-72-270?
Percentile placement of JA Solar JAP6(BK)-72-270 across power density (139.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for JA Solar JAP6(BK)-72-270?
Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAP6(BK)-72-270 specifications.
270.0 W STC · Higher Than 12.9%
270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.93% Aperture Efficiency
Power density 139.3 W/m2 (5.98 percentage points below 19.91% CEC median). PTC/STC ratio: 88.9% (rank #20,819).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.61 V at -10 C (595.3 V string) and 51.21 V at -20 C (11 max).
30 Panels = 8,100 W STC
Occupies 58.1 m2 (626 sq ft) producing 7,203 W PTC; NEC 690.8 OCPD floor is 12.79 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.0 * (1 + (-0.364/100) * (-10 - 25)) = 49.61 V | OCPD = 1.56 * 8.2 = 12.79 A
Inputs from CEC Modules.csv for JA Solar JAP6(BK)-72-270: Voc=44.0 V, beta_Voc=-0.364%/C, Isc=8.2 A, STC=270.0 W, Area=1.938 m2.
Result: 12 panels max on 600 V (595.3 V); 30 panels for 8 kW (626 sq ft).
What Are the Published CEC Specifications for JA Solar JAP6(BK)-72-270?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAP6(BK)-72-270.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 240.1 W (88.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.0 V / 7.5 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.364 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.93% (1.938 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many JA Solar JAP6(BK)-72-270 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAP6(BK)-72-270 (270.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.21 kW | 480 sq ft | $1,554 | $2,628 |
| 8 kW Class | 30 | 8.1 kW | 626 sq ft | $2,027 | $3,428 |
| 10 kW Class | 38 | 10.26 kW | 793 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAP6(BK)-72-270 architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAP6(BK)-72-265 | 265.0 W | 235.5 W | 44.0 V | 35.96 V | 13.67% |
| JA Solar JAP6(BK)-72-270 | 270.0 W | 240.1 W | 44.0 V | 36.0 V | 13.93% |
How Many JA Solar JAP6(BK)-72-270 Modules Fit in a Cold-Weather String?
Maximum series module counts for JA Solar JAP6(BK)-72-270 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.21 V | 11 panels | 563.3 V | 19 panels |
| -10 C (14 F) | 49.61 V | 12 panels | 595.3 V | 20 panels |
| 0 C (32 F) | 48.0 V | 12 panels | 576.0 V | 20 panels |
| 25 C (77 F STC) | 44.0 V | 13 panels | 572.0 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6(BK)-72-270?
Alternative CEC solar modules from competing brands near JA Solar JAP6(BK)-72-270 (270.0 W), including Centrosolar America DP72 270.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DP72 270 Centrosolar America |
270.0 W | Tie (0 W) | 43.85 V | 13.89% | 88.4% |
| AXITEC AC-270P/156-72S AXITEC |
270.0 W | Tie (0 W) | 44.18 V | 13.94% | 89.9% |
| Anhui Rinengzhongtian Semiconductor Development QJM270-72 Anhui Rinengzhongtian Semiconductor Development |
270.0 W | Tie (0 W) | 43.67 V | 13.92% | 89.6% |
| Advance Power API-M270 Advance Power |
270.0 W | Tie (0 W) | 44.64 V | 13.84% | 89.0% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAP6(BK)-72-270?
Evaluate JA Solar JAP6(BK)-72-270 (270.0 W STC, 44.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6(BK)-72-270 reaches 51.21 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 626 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (626 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6(BK)-72-270 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAP6(BK)-72-270 8 kW Residential Fit
Needs 30 modules (626 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DP72 270.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 240.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAP6(BK)-72-270 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is JA Solar JAP6(BK)-72-270 PTC wattage (240.1 W) lower than STC (270.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 240.1 W PTC (88.9% retention) across JA Solar JAP6(BK)-72-270's 1.938 m2 aperture.
Who should skip JA Solar JAP6(BK)-72-270 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 30 JA Solar JAP6(BK)-72-270 panels (626 sq ft) leave unusable roof gaps vs. Centrosolar America DP72 270.
What is the 1,000 V commercial string limit for JA Solar JAP6(BK)-72-270?
On 1,000 V commercial inverters at -10 C (49.61 V cold Voc), JA Solar JAP6(BK)-72-270 fits up to 20 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)