Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP6(BK)-60-250 is a 250.0 W STC (222.9 W PTC) Multi-c-Si solar module ranking #19,686 of 21,677 CEC listings (below all-CEC median; higher than 8.0% of peers). It delivers 15.29% efficiency, 37.85 V Voc at 25 C, and 42.67 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
250.0 W
PTC Wattage
222.9 W
Voc @ 25C
37.85 V
Efficiency
15.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP6(BK)-60-250 Compare Against Peer CEC Listings?

Engineering position of JA Solar JAP6(BK)-60-250 (250.0 W STC) vs. Changzhou Nesl Solartech DJ-250DA/C-ST15 across 1,407 CEC Multi-c-Si solar modules.

Ranking #19,686 across 21,677 CEC solar panels (below all-CEC median; higher than 8.0% of peers), JA Solar JAP6(BK)-60-250 operates as a compact residential or specialty off-grid module sitting 28.8 W below the 278.8 W Multi-c-Si median. Lower 37.85 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 89.2% PTC-to-STC thermal output (222.9 W real-world rating), 32 panels occupy 563 sq ft and offset roughly $2,002/yr at average US rates (or $3,386/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does JA Solar JAP6(BK)-60-250 Fall Across Listed CEC Models?

Plots JA Solar JAP6(BK)-60-250 at 250.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP6(BK)-60-250 (250.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP6(BK)-: 250.0 W

What Dataset Percentiles Define JA Solar JAP6(BK)-60-250?

Benchmarks JA Solar JAP6(BK)-60-250 on STC wattage, thermal PTC/STC retention, and 15.29 aperture conversion efficiency against CEC peers.

JA Solar JAP6(BK)-60-250 Engineering BenchmarksPercentile comparison of JA Solar JAP6(BK)-60-250 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage250.0 WPTC/STC Retention89.2%Module Efficiency15.29%

What Do the Dataset Ranks Show for JA Solar JAP6(BK)-60-250?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAP6(BK)-60-250 by JA Solar.

Rank #19,686 / 21,677

250.0 W STC · Higher Than 8.0%

250.0 W STC (-135.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,272

15.29% Aperture Efficiency

Power density 152.9 W/m2 (4.62 percentage points below 19.91% CEC median). PTC/STC ratio: 89.2% (rank #20,311).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.67 V at -10 C (597.4 V string) and 44.05 V at -20 C (13 max).

8 kW Reference Array

32 Panels = 8,000 W STC

Occupies 52.3 m2 (563 sq ft) producing 7,133 W PTC; NEC 690.8 OCPD floor is 13.49 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.85 * (1 + (-0.364/100) * (-10 - 25)) = 42.67 V | OCPD = 1.56 * 8.65 = 13.49 A

Inputs from CEC Modules.csv for JA Solar JAP6(BK)-60-250: Voc=37.85 V, beta_Voc=-0.364%/C, Isc=8.65 A, STC=250.0 W, Area=1.635 m2.

Result: 14 panels max on 600 V (597.4 V); 32 panels for 8 kW (563 sq ft).

What Are the Published CEC Specifications for JA Solar JAP6(BK)-60-250?

Laboratory test ratings recorded for JA Solar JAP6(BK)-60-250 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6(BK)-60-250.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 250.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 222.9 W (89.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.85 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.65 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.12 V / 8.3 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.364 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.29% (1.635 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP6(BK)-60-250 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (563 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAP6(BK)-60-250.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.0 kW 422 sq ft $1,502 $2,539
8 kW Class 32 8.0 kW 563 sq ft $2,002 $3,386
10 kW Class 40 10.0 kW 704 sq ft $2,503 $4,232

How Many JA Solar JAP6(BK)-60-250 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAP6(BK)-60-250 (beta_Voc -0.364%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.85V and beta_Voc=-0.364%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.05 V 13 panels 572.6 V 22 panels
-10 C (14 F) 42.67 V 14 panels 597.4 V 23 panels
0 C (32 F) 41.29 V 14 panels 578.1 V 24 panels
25 C (77 F STC) 37.85 V 15 panels 567.8 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6(BK)-60-250?

Closest cross-brand CEC competitors to JA Solar JAP6(BK)-60-250 matched near 250.0 W STC and 37.85 V Voc, led by Changzhou Nesl Solartech DJ-250DA/C-ST15.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Changzhou Nesl Solartech DJ-250DA/C-ST15
Changzhou Nesl Solartech
250.0 W Tie (0 W) 38.07 V 15.3% 90.4%
Boviet Solar Technology Co Ltd BVM6610P-250
Boviet Solar Technology Co Ltd
250.0 W Tie (0 W) 37.5 V 15.37% 90.2%
Anji Technology AJP-M660-250
Anji Technology
250.0 W Tie (0 W) 37.32 V 15.4% 89.0%
Eoplly New Energy Technology EP156MB/60-250S AC
Eoplly New Energy Technology
250.0 W Tie (0 W) 37.26 V 15.45% 89.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP6(BK)-60-250?

Evaluate JA Solar JAP6(BK)-60-250 (250.0 W STC, 37.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6(BK)-60-250 reaches 44.05 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 32 panels for an 8 kW build require 563 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (563 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP6(BK)-60-250 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP6(BK)-60-250 8 kW Residential Fit

Needs 32 modules (563 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Changzhou Nesl Solartech DJ-250DA/C-ST15.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 222.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6(BK)-60-250 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAP6(BK)-60-250 panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAP6(BK)-60-250 cold Voc rises from 37.85 V to 42.67 V (beta_Voc -0.364%/C), capping a 600 V string at 14 panels (597.4 V).

How much roof area does an 8 kW array of JA Solar JAP6(BK)-60-250 need?

An 8 kW DC system uses 32 JA Solar JAP6(BK)-60-250 modules (8,000 W STC / 7,133 W PTC), covering roughly 563 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

How does JA Solar JAP6(BK)-60-250 compare against Changzhou Nesl Solartech DJ-250DA/C-ST15?

JA Solar JAP6(BK)-60-250 outputs 250.0 W STC (37.85 V Voc, rank #19,686 of 21,677), while Changzhou Nesl Solartech DJ-250DA/C-ST15 delivers 250.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.