JA Solar JAP6-72-310 — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP6-72-310 is a 310.0 W STC (281.0 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.99% efficiency, 45.61 V Voc at 25 C, and 50.86 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
281.0 W
Voc @ 25C
45.61 V
Efficiency
15.99%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP6-72-310 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAP6-72-310 (Multi-c-Si) residential solar systems.

JA Solar JAP6-72-310 delivers 160.0 W/m2 (3.92 percentage points below 19.91% CEC median) and typical 90.6% PTC-to-STC thermal output (281.0 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft). At -4 F (-20 C), string voltage climbs to 52.36 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with DEHUI SOLAR POWER INC DH-72P-310W (310.0 W).

Where Does JA Solar JAP6-72-310 Fall Across Listed CEC Models?

Comparison of JA Solar JAP6-72-310 (310.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP6-72-310 (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP6-72-3: 310.0 W

What Dataset Percentiles Define JA Solar JAP6-72-310?

Relative ranking of JA Solar JAP6-72-310 across nameplate watts, 90.6% PTC thermal ratio, and module aperture efficiency. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

JA Solar JAP6-72-310 Engineering BenchmarksPercentile comparison of JA Solar JAP6-72-310 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention90.6%Module Efficiency15.99%

What Do the Dataset Ranks Show for JA Solar JAP6-72-310?

Summary of JA Solar JAP6-72-310 output rank, 8 kW array size (26 panels), efficiency rating, and 600 V string limit.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,133

15.99% Aperture Efficiency

Power density 160.0 W/m2 (3.92 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.86 V at -10 C (559.5 V string) and 52.36 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 50.4 m2 (542 sq ft) producing 7,306 W PTC; NEC 690.8 OCPD floor is 13.7 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.61 * (1 + (-0.329/100) * (-10 - 25)) = 50.86 V | OCPD = 1.56 * 8.78 = 13.7 A

Inputs from CEC Modules.csv for JA Solar JAP6-72-310: Voc=45.61 V, beta_Voc=-0.329%/C, Isc=8.78 A, STC=310.0 W, Area=1.938 m2.

Result: 11 panels max on 600 V (559.5 V); 26 panels for 8 kW (542 sq ft).

What Are the Published CEC Specifications for JA Solar JAP6-72-310?

Complete CEC test sheet for JA Solar JAP6-72-310 including Isc (8.78 A), Voc (45.61 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-72-310.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 281.0 W (90.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.61 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.78 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.49 V / 8.41 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.329 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.99% (1.938 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP6-72-310 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAP6-72-310.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 417 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 542 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 688 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAP6-72-310 series guide. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the JA Solar JAP6-72-310 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAP6-72-300 300.0 W 271.7 W 45.31 V 36.74 V 15.48%
JA Solar JAP6-72-305 305.0 W 276.3 W 45.42 V 36.36 V 15.73%
JA Solar JAP6-72-310 310.0 W 281.0 W 45.61 V 36.49 V 15.99%
JA Solar JAP6-72-315 315.0 W 285.6 W 45.91 V 36.72 V 16.25%

How Many JA Solar JAP6-72-310 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for JA Solar JAP6-72-310 (45.61 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.61V and beta_Voc=-0.329%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.36 V 11 panels 576.0 V 19 panels
-10 C (14 F) 50.86 V 11 panels 559.5 V 19 panels
0 C (32 F) 49.36 V 12 panels 592.3 V 20 panels
25 C (77 F STC) 45.61 V 13 panels 592.9 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-72-310?

Four comparable CEC modules such as DEHUI SOLAR POWER INC DH-72P-310W (310.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DEHUI SOLAR POWER INC DH-72P-310W
DEHUI SOLAR POWER INC
310.0 W Tie (0 W) 45.6 V 16.12% 90.5%
Centrosolar America DM72 310
Centrosolar America
310.0 W Tie (0 W) 45.7 V 15.94% 90.8%
Centrosolar America TP7 310xx
Centrosolar America
310.0 W Tie (0 W) 45.7 V 15.89% 90.5%
Centrosolar America TP7S 310xx
Centrosolar America
310.0 W Tie (0 W) 45.7 V 15.89% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-72-310?

Evaluate JA Solar JAP6-72-310 (310.0 W STC, 45.61 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-72-310 reaches 52.36 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP6-72-310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP6-72-310 8 kW Residential Fit

Needs 26 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare DEHUI SOLAR POWER INC DH-72P-310W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 281.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-72-310 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAP6-72-310 panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAP6-72-310 cold Voc rises from 45.61 V to 50.86 V (beta_Voc -0.329%/C), capping a 600 V string at 11 panels (559.5 V).

How much roof area does an 8 kW array of JA Solar JAP6-72-310 need?

An 8 kW DC system uses 26 JA Solar JAP6-72-310 modules (8,060 W STC / 7,306 W PTC), covering roughly 542 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does JA Solar JAP6-72-310 compare against DEHUI SOLAR POWER INC DH-72P-310W?

JA Solar JAP6-72-310 outputs 310.0 W STC (45.61 V Voc, rank #15,760 of 21,677), while DEHUI SOLAR POWER INC DH-72P-310W delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.