JA Solar JAP6-72-295 is a 295.0 W STC (264.1 W PTC) Multi-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 15.11% efficiency, 44.6 V Voc at 25 C, and 49.75 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 295.0 W
- PTC Wattage
- 264.1 W
- Voc @ 25C
- 44.6 V
- Efficiency
- 15.11%
How Does JA Solar JAP6-72-295 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAP6-72-295 (Multi-c-Si) residential solar systems.
Homeowners evaluating JA Solar JAP6-72-295 need 21 panels for 6 kW or 28 panels (588 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (588 sq ft). Under NEC 690.7(A), beta_Voc (-0.33%/C) pushes open-circuit voltage to 49.75 V at 14 F and 51.22 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does JA Solar JAP6-72-295 Fall Across Listed CEC Models?
Comparison of JA Solar JAP6-72-295 (295.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Dataset Percentiles Define JA Solar JAP6-72-295?
Relative ranking of JA Solar JAP6-72-295 across nameplate watts, 89.5% PTC thermal ratio, and module aperture efficiency. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Do the Dataset Ranks Show for JA Solar JAP6-72-295?
Summary of JA Solar JAP6-72-295 output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.
295.0 W STC · Higher Than 20.4%
295.0 W STC (-90.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.11% Aperture Efficiency
Power density 151.1 W/m2 (4.80 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.75 V at -10 C (597.0 V string) and 51.22 V at -20 C (11 max).
28 Panels = 8,260 W STC
Occupies 54.7 m2 (588 sq ft) producing 7,395 W PTC; NEC 690.8 OCPD floor is 13.23 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.6 * (1 + (-0.33/100) * (-10 - 25)) = 49.75 V | OCPD = 1.56 * 8.48 = 13.23 A
Inputs from CEC Modules.csv for JA Solar JAP6-72-295: Voc=44.6 V, beta_Voc=-0.33%/C, Isc=8.48 A, STC=295.0 W, Area=1.952 m2.
Result: 12 panels max on 600 V (597.0 V); 28 panels for 8 kW (588 sq ft).
What Are the Published CEC Specifications for JA Solar JAP6-72-295?
Complete CEC test sheet for JA Solar JAP6-72-295 including Isc (8.48 A), Voc (44.6 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 264.1 W (89.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.48 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.82 V / 7.8 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.11% (1.952 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many JA Solar JAP6-72-295 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAP6-72-295.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.2 kW | 441 sq ft | $1,552 | $2,624 |
| 8 kW Class | 28 | 8.26 kW | 588 sq ft | $2,067 | $3,496 |
| 10 kW Class | 34 | 10.03 kW | 714 sq ft | $2,510 | $4,245 |
How Many JA Solar JAP6-72-295 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for JA Solar JAP6-72-295 (44.6 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.22 V | 11 panels | 563.4 V | 19 panels |
| -10 C (14 F) | 49.75 V | 12 panels | 597.0 V | 20 panels |
| 0 C (32 F) | 48.28 V | 12 panels | 579.4 V | 20 panels |
| 25 C (77 F STC) | 44.6 V | 13 panels | 579.8 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-72-295?
Four comparable CEC modules such as Chinaland Solar Energy HSE295-72M (295.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Chinaland Solar Energy HSE295-72M Chinaland Solar Energy |
295.0 W | Tie (0 W) | 44.4 V | 15.28% | 90.2% |
| BYD Company Limited BYD295P6K-36 BYD Company Limited |
295.0 W | Tie (0 W) | 44.9 V | 15.21% | 91.5% |
| Centrosolar America TP7 295xx Centrosolar America |
295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |
| Centrosolar America TP7S 295xx Centrosolar America |
295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-72-295?
Evaluate JA Solar JAP6-72-295 (295.0 W STC, 44.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-72-295 reaches 51.22 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 588 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (588 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-72-295 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAP6-72-295 8 kW Residential Fit
Needs 28 modules (588 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Chinaland Solar Energy HSE295-72M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 264.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAP6-72-295 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is JA Solar JAP6-72-295 PTC wattage (264.1 W) lower than STC (295.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 264.1 W PTC (89.5% retention) across JA Solar JAP6-72-295's 1.952 m2 aperture.
Who should skip JA Solar JAP6-72-295 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 JA Solar JAP6-72-295 panels (588 sq ft) leave unusable roof gaps vs. Chinaland Solar Energy HSE295-72M.
What is the 1,000 V commercial string limit for JA Solar JAP6-72-295?
On 1,000 V commercial inverters at -10 C (49.75 V cold Voc), JA Solar JAP6-72-295 fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAP6-72-295.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)