Skip to main content
WireAndSun
Calculators
CEC PV Module

JA Solar JAP6-60-280/4BB/RE — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP6-60-280/4BB/RE is a 280.0 W STC (256.7 W PTC) Multi-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 17.12% efficiency, 38.85 V Voc at 25 C, and 42.94 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
280.0 W
PTC Wattage
256.7 W
Voc @ 25C
38.85 V
Efficiency
17.12%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP6-60-280/4BB/RE Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAP6-60-280/4BB/RE (Multi-c-Si) residential solar systems.

Homeowners evaluating JA Solar JAP6-60-280/4BB/RE need 22 panels for 6 kW or 29 panels (510 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (510 sq ft). Under NEC 690.7(A), beta_Voc (-0.301%/C) pushes open-circuit voltage to 42.94 V at 14 F and 44.11 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does JA Solar JAP6-60-280/4BB/RE Fall Across Listed CEC Models?

Comparison of JA Solar JAP6-60-280/4BB/RE (280.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP6-60-280/4BB/RE (280.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP6-60-2: 280.0 W

What Dataset Percentiles Define JA Solar JAP6-60-280/4BB/RE?

Relative ranking of JA Solar JAP6-60-280/4BB/RE across nameplate watts, 91.7% PTC thermal ratio, and module aperture efficiency.

JA Solar JAP6-60-280/4BB/RE Engineering BenchmarksPercentile comparison of JA Solar JAP6-60-280/4BB/RE wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage280.0 WPTC/STC Retention91.7%Module Efficiency17.12%

What Do the Dataset Ranks Show for JA Solar JAP6-60-280/4BB/RE?

Summary of JA Solar JAP6-60-280/4BB/RE output rank, 8 kW array size (29 panels), efficiency rating, and 600 V string limit.

Rank #17,941 / 21,677

280.0 W STC · Higher Than 15.8%

280.0 W STC (-105.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,307

17.12% Aperture Efficiency

Power density 171.3 W/m2 (2.79 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.94 V at -10 C (558.2 V string) and 44.11 V at -20 C (13 max).

8 kW Reference Array

29 Panels = 8,120 W STC

Occupies 47.4 m2 (510 sq ft) producing 7,444 W PTC; NEC 690.8 OCPD floor is 14.55 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.85 * (1 + (-0.301/100) * (-10 - 25)) = 42.94 V | OCPD = 1.56 * 9.33 = 14.55 A

Inputs from CEC Modules.csv for JA Solar JAP6-60-280/4BB/RE: Voc=38.85 V, beta_Voc=-0.301%/C, Isc=9.33 A, STC=280.0 W, Area=1.635 m2.

Result: 13 panels max on 600 V (558.2 V); 29 panels for 8 kW (510 sq ft).

What Are the Published CEC Specifications for JA Solar JAP6-60-280/4BB/RE?

Complete CEC test sheet for JA Solar JAP6-60-280/4BB/RE including Isc (9.33 A), Voc (38.85 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-60-280/4BB/RE.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 280.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 256.7 W (91.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.85 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.33 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.88 V / 8.78 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.301 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.12% (1.635 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP6-60-280/4BB/RE Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAP6-60-280/4BB/RE.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.16 kW 387 sq ft $1,542 $2,607
8 kW Class 29 8.12 kW 510 sq ft $2,032 $3,437
10 kW Class 36 10.08 kW 634 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAP6-60-280/4BB/RE series guide.

Sibling CEC listings grouped into the JA Solar JAP6-60-280/4BB/RE wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAP6-60-275/4BB/RE 275.0 W 252.0 W 38.46 V 31.54 V 16.82%
JA Solar JAP6-60-280/4BB/RE 280.0 W 256.7 W 38.85 V 31.88 V 17.12%

How Many JA Solar JAP6-60-280/4BB/RE Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for JA Solar JAP6-60-280/4BB/RE (38.85 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=38.85V and beta_Voc=-0.301%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.11 V 13 panels 573.4 V 22 panels
-10 C (14 F) 42.94 V 13 panels 558.2 V 23 panels
0 C (32 F) 41.77 V 14 panels 584.8 V 23 panels
25 C (77 F STC) 38.85 V 15 panels 582.8 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-280/4BB/RE?

Four comparable CEC modules such as Centrosolar America TM6 280xx (280.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America TM6 280xx
Centrosolar America
280.0 W Tie (0 W) 38.7 V 17.14% 90.6%
Centrosolar America TM6S 280xx
Centrosolar America
280.0 W Tie (0 W) 38.7 V 17.14% 90.6%
GCL System Integration Technology Co Ltd GCL-M6/60280
GCL System Integration Technology Co Ltd
280.0 W Tie (0 W) 38.7 V 17.18% 90.1%
GCL System Integration Technology Co Ltd GCL-P6/60280
GCL System Integration Technology Co Ltd
280.0 W Tie (0 W) 38.7 V 17.18% 90.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-280/4BB/RE?

Evaluate JA Solar JAP6-60-280/4BB/RE (280.0 W STC, 38.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-280/4BB/RE reaches 44.11 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 510 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (510 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-280/4BB/RE carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP6-60-280/4BB/RE 8 kW Residential Fit

Needs 29 modules (510 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America TM6 280xx.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 256.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-60-280/4BB/RE by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is JA Solar JAP6-60-280/4BB/RE PTC wattage (256.7 W) lower than STC (280.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 256.7 W PTC (91.7% retention) across JA Solar JAP6-60-280/4BB/RE's 1.635 m2 aperture.

Who should skip JA Solar JAP6-60-280/4BB/RE on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 29 JA Solar JAP6-60-280/4BB/RE panels (510 sq ft) leave unusable roof gaps vs. Centrosolar America TM6 280xx.

What is the 1,000 V commercial string limit for JA Solar JAP6-60-280/4BB/RE?

On 1,000 V commercial inverters at -10 C (42.94 V cold Voc), JA Solar JAP6-60-280/4BB/RE fits up to 23 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.