GCL System Integration Technology Co Ltd GCL-P6/60280 — CEC Solar Module Specifications

Manufacturer: GCL System Integration Technology Co Ltd Registry: CEC Verified Engineering Specification

GCL System Integration Technology Co Ltd GCL-P6/60280 is a 280.0 W STC (253.7 W PTC) Multi-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 17.18% efficiency, 38.7 V Voc at 25 C, and 43.71 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
280.0 W
PTC Wattage
253.7 W
Voc @ 25C
38.7 V
Efficiency
17.18%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does GCL System Integration Technology Co Ltd GCL-P6/60280 Compare Against Peer CEC Listings?

How GCL System Integration Technology Co Ltd GCL System Integration Technology Co Ltd GCL-P6/60280 handles rooftop heat (253.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, GCL System Integration Technology Co Ltd GCL-P6/60280 exhibits 9.46 A short-circuit current, requiring a 14.76 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #17,941 of 21,677 (1.2 W above the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 47.3 m2 for an 8 kW system (36 panels for 10 kW). Lower 38.7 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

Where Does GCL System Integration Technology Co Ltd GCL-P6/60280 Fall Across Listed CEC Models?

Where GCL System Integration Technology Co Ltd GCL-P6/60280 (280.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where GCL System Integration Technology Co Ltd GCL-P6/60280 (280.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGCL System Integra: 280.0 W

What Dataset Percentiles Define GCL System Integration Technology Co Ltd GCL-P6/60280?

Percentile placement of GCL System Integration Technology Co Ltd GCL-P6/60280 across power density (171.8 W/m2), thermal retention, and nameplate STC wattage.

GCL System Integration Technology Co Ltd GCL-P6/60280 Engineering BenchmarksPercentile comparison of GCL System Integration Technology Co Ltd GCL-P6/60280 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage280.0 WPTC/STC Retention90.6%Module Efficiency17.18%

What Do the Dataset Ranks Show for GCL System Integration Technology Co Ltd GCL-P6/60280?

Four critical engineering numbers homeowners and solar installers check first when reviewing GCL System Integration Technology Co Ltd GCL-P6/60280 specifications.

Rank #17,941 / 21,677

280.0 W STC · Higher Than 15.8%

280.0 W STC (-105.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,219

17.18% Aperture Efficiency

Power density 171.8 W/m2 (2.73 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.71 V at -10 C (568.2 V string) and 45.14 V at -20 C (13 max).

8 kW Reference Array

29 Panels = 8,120 W STC

Occupies 47.3 m2 (509 sq ft) producing 7,357 W PTC; NEC 690.8 OCPD floor is 14.76 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.7 * (1 + (-0.37/100) * (-10 - 25)) = 43.71 V | OCPD = 1.56 * 9.46 = 14.76 A

Inputs from CEC Modules.csv for GCL System Integration Technology Co Ltd GCL-P6/60280: Voc=38.7 V, beta_Voc=-0.37%/C, Isc=9.46 A, STC=280.0 W, Area=1.63 m2.

Result: 13 panels max on 600 V (568.2 V); 29 panels for 8 kW (509 sq ft).

What Are the Published CEC Specifications for GCL System Integration Technology Co Ltd GCL-P6/60280?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for GCL System Integration Technology Co Ltd GCL-P6/60280.

Official California Energy Commission (NREL SAM) test parameters for GCL System Integration Technology Co Ltd GCL-P6/60280.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 280.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 253.7 W (90.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.46 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.6 V / 8.86 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.37 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.18% (1.63 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many GCL System Integration Technology Co Ltd GCL-P6/60280 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using GCL System Integration Technology Co Ltd GCL-P6/60280 (280.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.16 kW 386 sq ft $1,542 $2,607
8 kW Class 29 8.12 kW 509 sq ft $2,032 $3,437
10 kW Class 36 10.08 kW 632 sq ft $2,523 $4,266

How Many GCL System Integration Technology Co Ltd GCL-P6/60280 Modules Fit in a Cold-Weather String?

Maximum series module counts for GCL System Integration Technology Co Ltd GCL-P6/60280 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.7V and beta_Voc=-0.37%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.14 V 13 panels 586.8 V 22 panels
-10 C (14 F) 43.71 V 13 panels 568.2 V 22 panels
0 C (32 F) 42.28 V 14 panels 591.9 V 23 panels
25 C (77 F STC) 38.7 V 15 panels 580.5 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to GCL System Integration Technology Co Ltd GCL-P6/60280?

Alternative CEC solar modules from competing brands near GCL System Integration Technology Co Ltd GCL-P6/60280 (280.0 W), including Centrosolar America TM6 280xx.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America TM6 280xx
Centrosolar America
280.0 W Tie (0 W) 38.7 V 17.14% 90.6%
Centrosolar America TM6S 280xx
Centrosolar America
280.0 W Tie (0 W) 38.7 V 17.14% 90.6%
GermanSolar USA Inc GSP-280W
GermanSolar USA Inc
280.0 W Tie (0 W) 38.55 V 16.87% 92.1%
CSI Solar Co Ltd CS6P-280M
CSI Solar Co Ltd
280.0 W Tie (0 W) 38.5 V 18.08% 90.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for GCL System Integration Technology Co Ltd GCL-P6/60280?

Evaluate GCL System Integration Technology Co Ltd GCL-P6/60280 (280.0 W STC, 38.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), GCL System Integration Technology Co Ltd GCL-P6/60280 reaches 45.14 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 509 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (509 sq ft).
  • 2026 tax credit baseline: cash residential installs of GCL System Integration Technology Co Ltd GCL-P6/60280 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

GCL System Integration Technology Co Ltd GCL-P6/60280 8 kW Residential Fit

Needs 29 modules (509 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America TM6 280xx.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 253.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for GCL System Integration Technology Co Ltd GCL-P6/60280 by GCL System Integration Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is GCL System Integration Technology Co Ltd GCL-P6/60280 PTC wattage (253.7 W) lower than STC (280.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 253.7 W PTC (90.6% retention) across GCL System Integration Technology Co Ltd GCL-P6/60280's 1.63 m2 aperture.

Who should skip GCL System Integration Technology Co Ltd GCL-P6/60280 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 29 GCL System Integration Technology Co Ltd GCL-P6/60280 panels (509 sq ft) leave unusable roof gaps vs. Centrosolar America TM6 280xx.

What is the 1,000 V commercial string limit for GCL System Integration Technology Co Ltd GCL-P6/60280?

On 1,000 V commercial inverters at -10 C (43.71 V cold Voc), GCL System Integration Technology Co Ltd GCL-P6/60280 fits up to 22 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.