CSI Solar Co Ltd CS6P-280M is a 280.0 W STC (254.2 W PTC) Mono-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 18.08% efficiency, 38.5 V Voc at 25 C, and 43.34 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 280.0 W
- PTC Wattage
- 254.2 W
- Voc @ 25C
- 38.5 V
- Efficiency
- 18.08%
How Does CSI Solar Co Ltd CS6P-280M Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for CSI Solar Co Ltd CS6P-280M (Mono-c-Si) residential solar systems.
Homeowners evaluating CSI Solar Co Ltd CS6P-280M need 22 panels for 6 kW or 29 panels (484 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (484 sq ft). Under NEC 690.7(A), beta_Voc (-0.359%/C) pushes open-circuit voltage to 43.34 V at 14 F and 44.72 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does CSI Solar Co Ltd CS6P-280M Fall Across Listed CEC Models?
Comparison of CSI Solar Co Ltd CS6P-280M (280.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define CSI Solar Co Ltd CS6P-280M?
Relative ranking of CSI Solar Co Ltd CS6P-280M across nameplate watts, 90.8% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS6P-280M?
Summary of CSI Solar Co Ltd CS6P-280M output rank, 8 kW array size (29 panels), efficiency rating, and 600 V string limit.
280.0 W STC · Higher Than 15.8%
280.0 W STC (-105.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.08% Aperture Efficiency
Power density 180.8 W/m2 (1.83 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.34 V at -10 C (563.4 V string) and 44.72 V at -20 C (13 max).
29 Panels = 8,120 W STC
Occupies 44.9 m2 (484 sq ft) producing 7,372 W PTC; NEC 690.8 OCPD floor is 14.71 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.5 * (1 + (-0.359/100) * (-10 - 25)) = 43.34 V | OCPD = 1.56 * 9.43 = 14.71 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS6P-280M: Voc=38.5 V, beta_Voc=-0.359%/C, Isc=9.43 A, STC=280.0 W, Area=1.549 m2.
Result: 13 panels max on 600 V (563.4 V); 29 panels for 8 kW (484 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS6P-280M?
Complete CEC test sheet for CSI Solar Co Ltd CS6P-280M including Isc (9.43 A), Voc (38.5 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 280.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 254.2 W (90.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.43 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.5 V / 8.89 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.359 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.08% (1.549 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS6P-280M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using CSI Solar Co Ltd CS6P-280M.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.16 kW | 367 sq ft | $1,542 | $2,607 |
| 8 kW Class | 29 | 8.12 kW | 484 sq ft | $2,032 | $3,437 |
| 10 kW Class | 36 | 10.08 kW | 600 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
Related CSI Solar Co Ltd power steps and black/silver trims consolidated into this CSI Solar Co Ltd CS6P-280M series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6P-275M | 275.0 W | 249.5 W | 38.3 V | 31.3 V | 17.76% |
| CSI Solar Co Ltd CS6P-280M | 280.0 W | 254.2 W | 38.5 V | 31.5 V | 18.08% |
| CSI Solar Co Ltd CS6P-285M | 285.0 W | 258.9 W | 38.6 V | 31.7 V | 18.4% |
How Many CSI Solar Co Ltd CS6P-280M Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for CSI Solar Co Ltd CS6P-280M (38.5 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.72 V | 13 panels | 581.4 V | 22 panels |
| -10 C (14 F) | 43.34 V | 13 panels | 563.4 V | 23 panels |
| 0 C (32 F) | 41.96 V | 14 panels | 587.4 V | 23 panels |
| 25 C (77 F STC) | 38.5 V | 15 panels | 577.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS6P-280M?
Four comparable CEC modules such as GermanSolar USA Inc GSP-280W (280.0 W) for side-by-side solar quote checks. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GermanSolar USA Inc GSP-280W GermanSolar USA Inc |
280.0 W | Tie (0 W) | 38.55 V | 16.87% | 92.1% |
| Centrosolar America TM6 280xx Centrosolar America |
280.0 W | Tie (0 W) | 38.7 V | 17.14% | 90.6% |
| Centrosolar America TM6S 280xx Centrosolar America |
280.0 W | Tie (0 W) | 38.7 V | 17.14% | 90.6% |
| GCL System Integration Technology Co Ltd GCL-M6/60280 GCL System Integration Technology Co Ltd |
280.0 W | Tie (0 W) | 38.7 V | 17.18% | 90.1% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS6P-280M?
Evaluate CSI Solar Co Ltd CS6P-280M (280.0 W STC, 38.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS6P-280M reaches 44.72 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 484 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (484 sq ft).
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS6P-280M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS6P-280M 8 kW Residential Fit
Needs 29 modules (484 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GermanSolar USA Inc GSP-280W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 254.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS6P-280M by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is CSI Solar Co Ltd CS6P-280M PTC wattage (254.2 W) lower than STC (280.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 254.2 W PTC (90.8% retention) across CSI Solar Co Ltd CS6P-280M's 1.549 m2 aperture.
Who should skip CSI Solar Co Ltd CS6P-280M on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 29 CSI Solar Co Ltd CS6P-280M panels (484 sq ft) leave unusable roof gaps vs. GermanSolar USA Inc GSP-280W.
What is the 1,000 V commercial string limit for CSI Solar Co Ltd CS6P-280M?
On 1,000 V commercial inverters at -10 C (43.34 V cold Voc), CSI Solar Co Ltd CS6P-280M fits up to 23 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)