Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP6-60-245/3BB is a 245.0 W STC (218.3 W PTC) Multi-c-Si solar module ranking #19,942 of 21,677 CEC listings (below all-CEC median; higher than 7.0% of peers). It delivers 14.98% efficiency, 37.45 V Voc at 25 C, and 42.17 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
245.0 W
PTC Wattage
218.3 W
Voc @ 25C
37.45 V
Efficiency
14.98%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP6-60-245/3BB Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAP6-60-245/3BB (Multi-c-Si) residential solar systems.

JA Solar JAP6-60-245/3BB delivers 149.8 W/m2 (4.93 percentage points below 19.91% CEC median) and typical 89.1% PTC-to-STC thermal output (218.3 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (581 sq ft). At -4 F (-20 C), string voltage climbs to 43.52 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with BYD Company Limited BYD245P6K-30 (245.0 W).

Where Does JA Solar JAP6-60-245/3BB Fall Across Listed CEC Models?

Comparison of JA Solar JAP6-60-245/3BB (245.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP6-60-245/3BB (245.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP6-60-2: 245.0 W

What Dataset Percentiles Define JA Solar JAP6-60-245/3BB?

Relative ranking of JA Solar JAP6-60-245/3BB across nameplate watts, 89.1% PTC thermal ratio, and module aperture efficiency.

JA Solar JAP6-60-245/3BB Engineering BenchmarksPercentile comparison of JA Solar JAP6-60-245/3BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage245.0 WPTC/STC Retention89.1%Module Efficiency14.98%

What Do the Dataset Ranks Show for JA Solar JAP6-60-245/3BB?

Summary of JA Solar JAP6-60-245/3BB output rank, 8 kW array size (33 panels), efficiency rating, and 600 V string limit.

Rank #19,942 / 21,677

245.0 W STC · Higher Than 7.0%

245.0 W STC (-140.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,761

14.98% Aperture Efficiency

Power density 149.8 W/m2 (4.93 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.17 V at -10 C (590.4 V string) and 43.52 V at -20 C (13 max).

8 kW Reference Array

33 Panels = 8,085 W STC

Occupies 54.0 m2 (581 sq ft) producing 7,204 W PTC; NEC 690.8 OCPD floor is 13.7 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.45 * (1 + (-0.36/100) * (-10 - 25)) = 42.17 V | OCPD = 1.56 * 8.78 = 13.7 A

Inputs from CEC Modules.csv for JA Solar JAP6-60-245/3BB: Voc=37.45 V, beta_Voc=-0.36%/C, Isc=8.78 A, STC=245.0 W, Area=1.635 m2.

Result: 14 panels max on 600 V (590.4 V); 33 panels for 8 kW (581 sq ft).

What Are the Published CEC Specifications for JA Solar JAP6-60-245/3BB?

Complete CEC test sheet for JA Solar JAP6-60-245/3BB including Isc (8.78 A), Voc (37.45 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-60-245/3BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 245.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 218.3 W (89.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.45 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.78 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.63 V / 8.27 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.36 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.98% (1.635 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP6-60-245/3BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAP6-60-245/3BB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 25 6.12 kW 440 sq ft $1,532 $2,590
8 kW Class 33 8.09 kW 581 sq ft $2,025 $3,424
10 kW Class 41 10.04 kW 722 sq ft $2,513 $4,249

How Many JA Solar JAP6-60-245/3BB Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for JA Solar JAP6-60-245/3BB (37.45 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.45V and beta_Voc=-0.36%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.52 V 13 panels 565.8 V 22 panels
-10 C (14 F) 42.17 V 14 panels 590.4 V 23 panels
0 C (32 F) 40.82 V 14 panels 571.5 V 24 panels
25 C (77 F STC) 37.45 V 16 panels 599.2 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-245/3BB?

Four comparable CEC modules such as BYD Company Limited BYD245P6K-30 (245.0 W) for side-by-side solar quote checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
BYD Company Limited BYD245P6K-30
BYD Company Limited
245.0 W Tie (0 W) 37.45 V 15.03% 91.6%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-245W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
245.0 W Tie (0 W) 37.5 V 15.09% 88.3%
GermanSolar USA GSP6-60-245W
GermanSolar USA
245.0 W Tie (0 W) 37.5 V 14.89% 89.7%
Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-245T
Hanwha Qcells (Qidong) Co Ltd
245.0 W Tie (0 W) 37.5 V 14.83% 88.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-245/3BB?

Evaluate JA Solar JAP6-60-245/3BB (245.0 W STC, 37.45 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-245/3BB reaches 43.52 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 33 panels for an 8 kW build require 581 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (581 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-245/3BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP6-60-245/3BB 8 kW Residential Fit

Needs 33 modules (581 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare BYD Company Limited BYD245P6K-30.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 218.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-60-245/3BB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAP6-60-245/3BB panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAP6-60-245/3BB cold Voc rises from 37.45 V to 42.17 V (beta_Voc -0.36%/C), capping a 600 V string at 14 panels (590.4 V).

How much roof area does an 8 kW array of JA Solar JAP6-60-245/3BB need?

An 8 kW DC system uses 33 JA Solar JAP6-60-245/3BB modules (8,085 W STC / 7,204 W PTC), covering roughly 581 sq ft and saving ~$2,025/yr at 18.54 c/kWh.

How does JA Solar JAP6-60-245/3BB compare against BYD Company Limited BYD245P6K-30?

JA Solar JAP6-60-245/3BB outputs 245.0 W STC (37.45 V Voc, rank #19,942 of 21,677), while BYD Company Limited BYD245P6K-30 delivers 245.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.