JA Solar JAM78S10-440/MR is a 440.0 W STC (413.5 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.85% efficiency, 53.0 V Voc at 25 C, and 57.9 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 440.0 W
- PTC Wattage
- 413.5 W
- Voc @ 25C
- 53.0 V
- Efficiency
- 20.85%
How Does JA Solar JAM78S10-440/MR Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAM78S10-440/MR (Mono-c-Si) residential solar systems.
Homeowners evaluating JA Solar JAM78S10-440/MR need 14 panels for 6 kW or 19 panels (432 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 19 panels (432 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.264%/C) pushes open-circuit voltage to 57.9 V at 14 F and 59.3 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does JA Solar JAM78S10-440/MR Fall Across Listed CEC Models?
Comparison of JA Solar JAM78S10-440/MR (440.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define JA Solar JAM78S10-440/MR?
Relative ranking of JA Solar JAM78S10-440/MR across nameplate watts, 94.0% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for JA Solar JAM78S10-440/MR?
Summary of JA Solar JAM78S10-440/MR output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.
Top 31.6% STC Output
440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.85% Aperture Efficiency
Power density 208.5 W/m2 (0.94 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 57.9 V at -10 C (579.0 V string) and 59.3 V at -20 C (10 max).
19 Panels = 8,360 W STC
Occupies 40.1 m2 (432 sq ft) producing 7,856 W PTC; NEC 690.8 OCPD floor is 16.29 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 53.0 * (1 + (-0.264/100) * (-10 - 25)) = 57.9 V | OCPD = 1.56 * 10.44 = 16.29 A
Inputs from CEC Modules.csv for JA Solar JAM78S10-440/MR: Voc=53.0 V, beta_Voc=-0.264%/C, Isc=10.44 A, STC=440.0 W, Area=2.11 m2.
Result: 10 panels max on 600 V (579.0 V); 19 panels for 8 kW (432 sq ft).
What Are the Published CEC Specifications for JA Solar JAM78S10-440/MR?
Complete CEC test sheet for JA Solar JAM78S10-440/MR including Isc (10.44 A), Voc (53.0 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 413.5 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 53.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.44 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 44.87 V / 9.81 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.264 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.85% (2.11 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Monofacial backsheet |
How Many JA Solar JAM78S10-440/MR Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAM78S10-440/MR.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.16 kW | 318 sq ft | $1,542 | $2,607 |
| 8 kW Class | 19 | 8.36 kW | 432 sq ft | $2,092 | $3,538 |
| 10 kW Class | 23 | 10.12 kW | 522 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAM78S10-440/MR series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAM78S10-435/MR | 435.0 W | 408.6 W | 52.73 V | 44.5 V | 20.62% |
| JA Solar JAM78S10-440/MR | 440.0 W | 413.5 W | 53.0 V | 44.87 V | 20.85% |
| JA Solar JAM78S10-445/MR | 445.0 W | 418.3 W | 53.31 V | 45.18 V | 21.09% |
How Many JA Solar JAM78S10-440/MR Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for JA Solar JAM78S10-440/MR (53.0 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 59.3 V | 10 panels | 593.0 V | 16 panels |
| -10 C (14 F) | 57.9 V | 10 panels | 579.0 V | 17 panels |
| 0 C (32 F) | 56.5 V | 10 panels | 565.0 V | 17 panels |
| 25 C (77 F STC) | 53.0 V | 11 panels | 583.0 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM78S10-440/MR?
Four comparable CEC modules such as CSI Solar Co Ltd CS3Y-445P (445.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3Y-445P CSI Solar Co Ltd |
445.0 W | +5.0 W | 51.4 V | 19.43% | 93.0% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
440.0 W | Tie (0 W) | 49.6 V | 20.75% | 92.4% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-440W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
440.0 W | Tie (0 W) | 49.3 V | 20.56% | 92.6% |
| Apollo Renewables Inc Apollo-M672BH-440TW Apollo Renewables Inc |
440.0 W | Tie (0 W) | 49.2 V | 20.47% | 93.4% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM78S10-440/MR?
Evaluate JA Solar JAM78S10-440/MR (440.0 W STC, 53.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM78S10-440/MR reaches 59.3 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 432 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (432 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM78S10-440/MR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM78S10-440/MR 8 kW Residential Fit
Needs 19 modules (432 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-445P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 413.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM78S10-440/MR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is JA Solar JAM78S10-440/MR PTC wattage (413.5 W) lower than STC (440.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 413.5 W PTC (94.0% retention) across JA Solar JAM78S10-440/MR's 2.11 m2 aperture.
Who should skip JA Solar JAM78S10-440/MR on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 JA Solar JAM78S10-440/MR panels (432 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3Y-445P.
What is the 1,000 V commercial string limit for JA Solar JAM78S10-440/MR?
On 1,000 V commercial inverters at -10 C (57.9 V cold Voc), JA Solar JAM78S10-440/MR fits up to 17 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAM78S10-440/MR.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)