JA Solar JAM72S20-455/MR — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM72S20-455/MR is a 455.0 W STC (426.7 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 20.97% efficiency, 49.85 V Voc at 25 C, and 54.47 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
455.0 W
PTC Wattage
426.7 W
Voc @ 25C
49.85 V
Efficiency
20.97%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM72S20-455/MR Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAM72S20-455/MR: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 455.0 W STC and 426.7 W PTC, JA Solar JAM72S20-455/MR sits +70.0 W vs all-CEC median (top 26.2%; higher than 73.8% of peers) among 21,677 listed modules. Power density reaches 209.7 W/m2 (1.06 percentage points above 19.91% CEC median). Higher 49.85 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Apollo Renewables Inc Apollo-M672BH-455TW rates 455.0 W.

Where Does JA Solar JAM72S20-455/MR Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAM72S20-455/MR (455.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM72S20-455/MR (455.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM72S20-: 455.0 W

What Dataset Percentiles Define JA Solar JAM72S20-455/MR?

Dataset percentiles tracking JA Solar JAM72S20-455/MR power output, thermal retention ratio, and aperture efficiency against 21,677 models.

JA Solar JAM72S20-455/MR Engineering BenchmarksPercentile comparison of JA Solar JAM72S20-455/MR wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage455.0 WPTC/STC Retention93.8%Module Efficiency20.97%

What Do the Dataset Ranks Show for JA Solar JAM72S20-455/MR?

Benchmark highlights for JA Solar JAM72S20-455/MR covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #5,417 / 21,677

Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,536

20.97% Aperture Efficiency

Power density 209.7 W/m2 (1.06 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.47 V at -10 C (599.2 V string) and 55.79 V at -20 C (10 max).

8 kW Reference Array

18 Panels = 8,190 W STC

Occupies 39.1 m2 (420 sq ft) producing 7,681 W PTC; NEC 690.8 OCPD floor is 17.8 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.85 * (1 + (-0.265/100) * (-10 - 25)) = 54.47 V | OCPD = 1.56 * 11.41 = 17.8 A

Inputs from CEC Modules.csv for JA Solar JAM72S20-455/MR: Voc=49.85 V, beta_Voc=-0.265%/C, Isc=11.41 A, STC=455.0 W, Area=2.17 m2.

Result: 11 panels max on 600 V (599.2 V); 18 panels for 8 kW (420 sq ft).

What Are the Published CEC Specifications for JA Solar JAM72S20-455/MR?

Official CEC datasheet figures for JA Solar JAM72S20-455/MR (Mono-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM72S20-455/MR.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 455.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 426.7 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.85 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.41 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.82 V / 10.88 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.265 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.97% (2.17 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many JA Solar JAM72S20-455/MR Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAM72S20-455/MR modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.37 kW 327 sq ft $1,594 $2,696
8 kW Class 18 8.19 kW 420 sq ft $2,050 $3,466
10 kW Class 22 10.01 kW 514 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Consolidated JA Solar wattage variants sharing the JA Solar JAM72S20-455/MR mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the JA Solar JAM72S20-455/MR wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM72S20-450/MR 450.0 W 421.8 W 49.7 V 41.52 V 20.74%
JA Solar JAM72S20-455/MR 455.0 W 426.7 W 49.85 V 41.82 V 20.97%
JA Solar JAM72S20-460/MR 460.0 W 431.5 W 50.01 V 42.13 V 21.2%

How Many JA Solar JAM72S20-455/MR Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM72S20-455/MR (54.47 V at 14 F).

Computed from Voc=49.85V and beta_Voc=-0.265%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.79 V 10 panels 557.9 V 17 panels
-10 C (14 F) 54.47 V 11 panels 599.2 V 18 panels
0 C (32 F) 53.15 V 11 panels 584.6 V 18 panels
25 C (77 F STC) 49.85 V 12 panels 598.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72S20-455/MR?

Competing CEC solar panels closest to JA Solar JAM72S20-455/MR in nameplate wattage and Voc, starting with Apollo Renewables Inc Apollo-M672BH-455TW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Apollo Renewables Inc Apollo-M672BH-455TW
Apollo Renewables Inc
455.0 W Tie (0 W) 49.8 V 21.16% 93.5%
Bluesun Solar CoLtd BSM455M-72HPH
Bluesun Solar CoLtd
455.0 W Tie (0 W) 49.8 V 20.97% 92.8%
ELITE Solar ET-M672BH455TW
ELITE Solar
455.0 W Tie (0 W) 49.8 V 21.16% 93.5%
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455XI
HD HYUNDAI ENERGY SOLUTIONS CO LTD
455.0 W Tie (0 W) 50.0 V 20.97% 93.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM72S20-455/MR?

Evaluate JA Solar JAM72S20-455/MR (455.0 W STC, 49.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72S20-455/MR reaches 55.79 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (420 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM72S20-455/MR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM72S20-455/MR 8 kW Residential Fit

Needs 18 modules (420 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Apollo Renewables Inc Apollo-M672BH-455TW.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 426.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM72S20-455/MR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAM72S20-455/MR panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM72S20-455/MR cold Voc rises from 49.85 V to 54.47 V (beta_Voc -0.265%/C), capping a 600 V string at 11 panels (599.2 V).

How much roof area does an 8 kW array of JA Solar JAM72S20-455/MR need?

An 8 kW DC system uses 18 JA Solar JAM72S20-455/MR modules (8,190 W STC / 7,681 W PTC), covering roughly 420 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does JA Solar JAM72S20-455/MR compare against Apollo Renewables Inc Apollo-M672BH-455TW?

JA Solar JAM72S20-455/MR outputs 455.0 W STC (49.85 V Voc, rank #5,417 of 21,677), while Apollo Renewables Inc Apollo-M672BH-455TW delivers 455.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.