ELITE Solar ET-M672BH455TW is a 455.0 W STC (425.4 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.16% efficiency, 49.8 V Voc at 25 C, and 54.63 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 455.0 W
- PTC Wattage
- 425.4 W
- Voc @ 25C
- 49.8 V
- Efficiency
- 21.16%
How Does ELITE Solar ET-M672BH455TW Compare Against Peer CEC Listings?
Solar engineering breakdown for ELITE Solar ET-M672BH455TW: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
Measured at 455.0 W STC and 425.4 W PTC, ELITE Solar ET-M672BH455TW sits +70.0 W vs all-CEC median (top 26.2%; higher than 73.8% of peers) among 21,677 listed modules. Power density reaches 211.6 W/m2 (1.25 percentage points above 19.91% CEC median). Higher 49.8 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Apollo Renewables Inc Apollo-M672BH-455TW rates 455.0 W.
Where Does ELITE Solar ET-M672BH455TW Fall Across Listed CEC Models?
Distribution marker showing ELITE Solar ET-M672BH455TW (455.0 W) relative to the 385.0 W all-CEC solar panel median. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Dataset Percentiles Define ELITE Solar ET-M672BH455TW?
Dataset percentiles tracking ELITE Solar ET-M672BH455TW power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Do the Dataset Ranks Show for ELITE Solar ET-M672BH455TW?
Benchmark highlights for ELITE Solar ET-M672BH455TW covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Top 26.2% STC Output
455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.16% Aperture Efficiency
Power density 211.6 W/m2 (1.25 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.63 V at -10 C (546.3 V string) and 56.01 V at -20 C (10 max).
18 Panels = 8,190 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,657 W PTC; NEC 690.8 OCPD floor is 18.17 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.8 * (1 + (-0.277/100) * (-10 - 25)) = 54.63 V | OCPD = 1.56 * 11.65 = 18.17 A
Inputs from CEC Modules.csv for ELITE Solar ET-M672BH455TW: Voc=49.8 V, beta_Voc=-0.277%/C, Isc=11.65 A, STC=455.0 W, Area=2.15 m2.
Result: 10 panels max on 600 V (546.3 V); 18 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for ELITE Solar ET-M672BH455TW?
Official CEC datasheet figures for ELITE Solar ET-M672BH455TW (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 425.4 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.65 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.6 V / 10.93 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.277 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.16% (2.15 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many ELITE Solar ET-M672BH455TW Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many ELITE Solar ET-M672BH455TW modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.37 kW | 324 sq ft | $1,594 | $2,696 |
| 8 kW Class | 18 | 8.19 kW | 417 sq ft | $2,050 | $3,466 |
| 10 kW Class | 22 | 10.01 kW | 509 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This ELITE Solar Series?
Consolidated ELITE Solar wattage variants sharing the ELITE Solar ET-M672BH455TW mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| ELITE Solar ET-M672BH450TW | 450.0 W | 420.6 W | 49.6 V | 41.4 V | 20.93% |
| ELITE Solar ET-M672BH455TW | 455.0 W | 425.4 W | 49.8 V | 41.6 V | 21.16% |
How Many ELITE Solar ET-M672BH455TW Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on ELITE Solar ET-M672BH455TW (54.63 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.01 V | 10 panels | 560.1 V | 17 panels |
| -10 C (14 F) | 54.63 V | 10 panels | 546.3 V | 18 panels |
| 0 C (32 F) | 53.25 V | 11 panels | 585.8 V | 18 panels |
| 25 C (77 F STC) | 49.8 V | 12 panels | 597.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to ELITE Solar ET-M672BH455TW?
Competing CEC solar panels closest to ELITE Solar ET-M672BH455TW in nameplate wattage and Voc, starting with Apollo Renewables Inc Apollo-M672BH-455TW.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Apollo Renewables Inc Apollo-M672BH-455TW Apollo Renewables Inc |
455.0 W | Tie (0 W) | 49.8 V | 21.16% | 93.5% |
| Bluesun Solar CoLtd BSM455M-72HPH Bluesun Solar CoLtd |
455.0 W | Tie (0 W) | 49.8 V | 20.97% | 92.8% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455XI HD HYUNDAI ENERGY SOLUTIONS CO LTD |
455.0 W | Tie (0 W) | 50.0 V | 20.97% | 93.9% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455YI HD HYUNDAI ENERGY SOLUTIONS CO LTD |
455.0 W | Tie (0 W) | 50.0 V | 20.97% | 93.8% |
What Are the Design Limits and Best-Fit Uses for ELITE Solar ET-M672BH455TW?
Evaluate ELITE Solar ET-M672BH455TW (455.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), ELITE Solar ET-M672BH455TW reaches 56.01 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 417 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (417 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of ELITE Solar ET-M672BH455TW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
ELITE Solar ET-M672BH455TW 8 kW Residential Fit
Needs 18 modules (417 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Apollo Renewables Inc Apollo-M672BH-455TW.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 425.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for ELITE Solar ET-M672BH455TW by ELITE Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many ELITE Solar ET-M672BH455TW panels fit on a 600 V winter solar string?
At -10 C (14 F), ELITE Solar ET-M672BH455TW cold Voc rises from 49.8 V to 54.63 V (beta_Voc -0.277%/C), capping a 600 V string at 10 panels (546.3 V).
How much roof area does an 8 kW array of ELITE Solar ET-M672BH455TW need?
An 8 kW DC system uses 18 ELITE Solar ET-M672BH455TW modules (8,190 W STC / 7,657 W PTC), covering roughly 417 sq ft and saving ~$2,050/yr at 18.54 c/kWh.
How does ELITE Solar ET-M672BH455TW compare against Apollo Renewables Inc Apollo-M672BH-455TW?
ELITE Solar ET-M672BH455TW outputs 455.0 W STC (49.8 V Voc, rank #5,417 of 21,677), while Apollo Renewables Inc Apollo-M672BH-455TW delivers 455.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)