JA Solar JAM72S10-410/MR is a 410.0 W STC (384.1 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.03% efficiency, 50.12 V Voc at 25 C, and 54.8 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 384.1 W
- Voc @ 25C
- 50.12 V
- Efficiency
- 21.03%
How Does JA Solar JAM72S10-410/MR Compare Against Peer CEC Listings?
How JA Solar JA Solar JAM72S10-410/MR handles rooftop heat (384.1 W PTC), 8 kW sizing, and cold winter string voltage.
JA Solar builds the JA Solar JAM72S10-410/MR (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). Compared against Auxin Solar AXNG1M410B (410.0 W), this model holds strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677). Higher 50.12 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 16.3 A overcurrent floor served by a 20 A breaker.
Where Does JA Solar JAM72S10-410/MR Fall Across Listed CEC Models?
Where JA Solar JAM72S10-410/MR (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define JA Solar JAM72S10-410/MR?
Percentile placement of JA Solar JAM72S10-410/MR across power density (210.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for JA Solar JAM72S10-410/MR?
Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAM72S10-410/MR specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.03% Aperture Efficiency
Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.8 V at -10 C (548.0 V string) and 56.14 V at -20 C (10 max).
20 Panels = 8,200 W STC
Occupies 39.0 m2 (420 sq ft) producing 7,682 W PTC; NEC 690.8 OCPD floor is 16.3 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 50.12 * (1 + (-0.267/100) * (-10 - 25)) = 54.8 V | OCPD = 1.56 * 10.45 = 16.3 A
Inputs from CEC Modules.csv for JA Solar JAM72S10-410/MR: Voc=50.12 V, beta_Voc=-0.267%/C, Isc=10.45 A, STC=410.0 W, Area=1.95 m2.
Result: 10 panels max on 600 V (548.0 V); 20 panels for 8 kW (420 sq ft).
What Are the Published CEC Specifications for JA Solar JAM72S10-410/MR?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAM72S10-410/MR.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 384.1 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 50.12 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.45 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.88 V / 9.79 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.267 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.03% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many JA Solar JAM72S10-410/MR Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAM72S10-410/MR (410.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 315 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 420 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 525 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAM72S10-410/MR architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAM72S10-400/MR | 400.0 W | 374.5 W | 49.58 V | 41.33 V | 20.51% |
| JA Solar JAM72S10-405/MR | 405.0 W | 379.3 W | 49.86 V | 41.6 V | 20.77% |
| JA Solar JAM72S10-410/MR | 410.0 W | 384.1 W | 50.12 V | 41.88 V | 21.03% |
| JA Solar JAM72S10-415/MR | 415.0 W | 389.0 W | 50.41 V | 42.18 V | 21.28% |
How Many JA Solar JAM72S10-410/MR Modules Fit in a Cold-Weather String?
Maximum series module counts for JA Solar JAM72S10-410/MR from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.14 V | 10 panels | 561.4 V | 17 panels |
| -10 C (14 F) | 54.8 V | 10 panels | 548.0 V | 18 panels |
| 0 C (32 F) | 53.47 V | 11 panels | 588.2 V | 18 panels |
| 25 C (77 F STC) | 50.12 V | 11 panels | 551.3 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72S10-410/MR?
Alternative CEC solar modules from competing brands near JA Solar JAM72S10-410/MR (410.0 W), including Auxin Solar AXNG1M410B.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXNG1M410B Auxin Solar |
410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.4% |
| Auxin Solar AXNG1M410W Auxin Solar |
410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.3% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W Dehui Solar Power (Vietnam) CoLtd |
410.0 W | Tie (0 W) | 49.4 V | 21.47% | 92.6% |
| AXITEC AC-410MB/144V AXITEC |
410.0 W | Tie (0 W) | 49.3 V | 21.03% | 93.0% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM72S10-410/MR?
Evaluate JA Solar JAM72S10-410/MR (410.0 W STC, 50.12 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72S10-410/MR reaches 56.14 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM72S10-410/MR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM72S10-410/MR 8 kW Residential Fit
Needs 20 modules (420 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Auxin Solar AXNG1M410B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 384.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM72S10-410/MR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for JA Solar JAM72S10-410/MR?
Multiplying JA Solar JAM72S10-410/MR's 10.45 A short-circuit current by 1.56 equals 16.3 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can JA Solar JAM72S10-410/MR pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.8 V cold Voc at 14 F and handles 10.45 A Isc; string inverters cap JA Solar JAM72S10-410/MR at 10 panels on 600 V.
Is JA Solar JAM72S10-410/MR eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM72S10-410/MR rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)