JA Solar JAM72S10-405/PR is a 405.0 W STC (379.4 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.77% efficiency, 49.81 V Voc at 25 C, and 54.45 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 405.0 W
- PTC Wattage
- 379.4 W
- Voc @ 25C
- 49.81 V
- Efficiency
- 20.77%
How Does JA Solar JAM72S10-405/PR Compare Against Peer CEC Listings?
Engineering position of JA Solar JAM72S10-405/PR (405.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-405L-H across 5,889 CEC Mono-c-Si solar modules.
Ranking #8,961 across 21,677 CEC solar panels (top 43.4%; higher than 56.6% of peers), JA Solar JAM72S10-405/PR operates as a modern high-density residential and light-commercial module sitting 5.0 W below the 410.0 W Mono-c-Si median. Higher 49.81 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677), 20 panels occupy 420 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does JA Solar JAM72S10-405/PR Fall Across Listed CEC Models?
Plots JA Solar JAM72S10-405/PR at 405.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define JA Solar JAM72S10-405/PR?
Benchmarks JA Solar JAM72S10-405/PR on STC wattage, thermal PTC/STC retention, and 20.77 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for JA Solar JAM72S10-405/PR?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM72S10-405/PR by JA Solar.
Top 43.4% STC Output
405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.77% Aperture Efficiency
Power density 207.7 W/m2 (0.86 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.45 V at -10 C (599.0 V string) and 55.77 V at -20 C (10 max).
20 Panels = 8,100 W STC
Occupies 39.0 m2 (420 sq ft) producing 7,588 W PTC; NEC 690.8 OCPD floor is 16.1 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.81 * (1 + (-0.266/100) * (-10 - 25)) = 54.45 V | OCPD = 1.56 * 10.32 = 16.1 A
Inputs from CEC Modules.csv for JA Solar JAM72S10-405/PR: Voc=49.81 V, beta_Voc=-0.266%/C, Isc=10.32 A, STC=405.0 W, Area=1.95 m2.
Result: 11 panels max on 600 V (599.0 V); 20 panels for 8 kW (420 sq ft).
What Are the Published CEC Specifications for JA Solar JAM72S10-405/PR?
Laboratory test ratings recorded for JA Solar JAM72S10-405/PR (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 379.4 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.81 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.32 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.46 V / 9.77 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.266 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.77% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many JA Solar JAM72S10-405/PR Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (420 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM72S10-405/PR.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.08 kW | 315 sq ft | $1,522 | $2,573 |
| 8 kW Class | 20 | 8.1 kW | 420 sq ft | $2,027 | $3,428 |
| 10 kW Class | 25 | 10.12 kW | 525 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Sibling wattage bins and frame colors grouped with JA Solar JAM72S10-405/PR under JA Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAM72S10-400/PR | 400.0 W | 374.6 W | 49.5 V | 41.17 V | 20.51% |
| JA Solar JAM72S10-405/PR | 405.0 W | 379.4 W | 49.81 V | 41.46 V | 20.77% |
How Many JA Solar JAM72S10-405/PR Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for JA Solar JAM72S10-405/PR (beta_Voc -0.266%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.77 V | 10 panels | 557.7 V | 17 panels |
| -10 C (14 F) | 54.45 V | 11 panels | 599.0 V | 18 panels |
| 0 C (32 F) | 53.12 V | 11 panels | 584.3 V | 18 panels |
| 25 C (77 F STC) | 49.81 V | 12 panels | 597.7 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72S10-405/PR?
Closest cross-brand CEC competitors to JA Solar JAM72S10-405/PR matched near 405.0 W STC and 49.81 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-405L-H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612M-405L-H Boviet Solar Technology Co Ltd |
405.0 W | Tie (0 W) | 49.45 V | 20.35% | 93.3% |
| Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC Boviet Solar Technology Co Ltd |
405.0 W | Tie (0 W) | 49.45 V | 19.95% | 93.6% |
| CSI Solar Co Ltd CS3U-405MS CSI Solar Co Ltd |
405.0 W | Tie (0 W) | 49.3 V | 21.09% | 93.0% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
405.0 W | Tie (0 W) | 49.2 V | 21.2% | 92.6% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM72S10-405/PR?
Evaluate JA Solar JAM72S10-405/PR (405.0 W STC, 49.81 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72S10-405/PR reaches 55.77 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM72S10-405/PR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM72S10-405/PR 8 kW Residential Fit
Needs 20 modules (420 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-405L-H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 379.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM72S10-405/PR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many JA Solar JAM72S10-405/PR panels fit on a 600 V winter solar string?
At -10 C (14 F), JA Solar JAM72S10-405/PR cold Voc rises from 49.81 V to 54.45 V (beta_Voc -0.266%/C), capping a 600 V string at 11 panels (599.0 V).
How much roof area does an 8 kW array of JA Solar JAM72S10-405/PR need?
An 8 kW DC system uses 20 JA Solar JAM72S10-405/PR modules (8,100 W STC / 7,588 W PTC), covering roughly 420 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does JA Solar JAM72S10-405/PR compare against Boviet Solar Technology Co Ltd BVM6612M-405L-H?
JA Solar JAM72S10-405/PR outputs 405.0 W STC (49.81 V Voc, rank #8,961 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-405L-H delivers 405.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)