Skip to main content
WireAndSun
Calculators
CEC PV Module

JA Solar JAM72D30-550/MB — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM72D30-550/MB is a 550.0 W STC (516.4 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.83% efficiency, 49.9 V Voc at 25 C, and 54.46 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
550.0 W
PTC Wattage
516.4 W
Voc @ 25C
49.9 V
Efficiency
21.83%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM72D30-550/MB Compare Against Peer CEC Listings?

How JA Solar JA Solar JAM72D30-550/MB handles rooftop heat (516.4 W PTC), 8 kW sizing, and cold winter string voltage.

JA Solar builds the JA Solar JAM72D30-550/MB (Mono-c-Si) as a large-format commercial and ground-mount module delivering 218.3 W/m2 (1.92 percentage points above 19.91% CEC median). Compared against AMPS Solar AMPS-550P-144BB (550.0 W), this model holds strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677). Higher 49.9 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 21.84 A overcurrent floor served by a 25 A breaker.

Where Does JA Solar JAM72D30-550/MB Fall Across Listed CEC Models?

Where JA Solar JAM72D30-550/MB (550.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM72D30-550/MB (550.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM72D30-: 550.0 W

What Dataset Percentiles Define JA Solar JAM72D30-550/MB?

Percentile placement of JA Solar JAM72D30-550/MB across power density (218.3 W/m2), thermal retention, and nameplate STC wattage.

JA Solar JAM72D30-550/MB Engineering BenchmarksPercentile comparison of JA Solar JAM72D30-550/MB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage550.0 WPTC/STC Retention93.9%Module Efficiency21.83%

What Do the Dataset Ranks Show for JA Solar JAM72D30-550/MB?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAM72D30-550/MB specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #2,737 / 21,677

Top 13.8% STC Output

550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,538

21.83% Aperture Efficiency

Power density 218.3 W/m2 (1.92 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.46 V at -10 C (599.1 V string) and 55.76 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,250 W STC

Occupies 37.8 m2 (407 sq ft) producing 7,746 W PTC; NEC 690.8 OCPD floor is 21.84 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.9 * (1 + (-0.261/100) * (-10 - 25)) = 54.46 V | OCPD = 1.56 * 14.0 = 21.84 A

Inputs from CEC Modules.csv for JA Solar JAM72D30-550/MB: Voc=49.9 V, beta_Voc=-0.261%/C, Isc=14.0 A, STC=550.0 W, Area=2.52 m2.

Result: 11 panels max on 600 V (599.1 V); 15 panels for 8 kW (407 sq ft).

What Are the Published CEC Specifications for JA Solar JAM72D30-550/MB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAM72D30-550/MB.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM72D30-550/MB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 550.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 516.4 W (93.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.0 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.96 V / 13.11 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.261 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.83% (2.52 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many JA Solar JAM72D30-550/MB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAM72D30-550/MB (550.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.05 kW 298 sq ft $1,514 $2,561
8 kW Class 15 8.25 kW 407 sq ft $2,065 $3,492
10 kW Class 19 10.45 kW 515 sq ft $2,616 $4,423

How Many JA Solar JAM72D30-550/MB Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAM72D30-550/MB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.9V and beta_Voc=-0.261%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.76 V 10 panels 557.6 V 17 panels
-10 C (14 F) 54.46 V 11 panels 599.1 V 18 panels
0 C (32 F) 53.16 V 11 panels 584.8 V 18 panels
25 C (77 F STC) 49.9 V 12 panels 598.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72D30-550/MB?

Alternative CEC solar modules from competing brands near JA Solar JAM72D30-550/MB (550.0 W), including AMPS Solar AMPS-550P-144BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AMPS Solar AMPS-550P-144BB
AMPS Solar
550.0 W Tie (0 W) 49.9 V 28.95% 94.1%
Apollo Renewables Inc Apollo-M772BH-550TW
Apollo Renewables Inc
550.0 W Tie (0 W) 49.9 V 21.48% 93.6%
Exiom Solution S A EX550-144BMH-DG
Exiom Solution S A
550.0 W Tie (0 W) 49.9 V 21.32% 93.4%
Exiom Solution S A EX550-144M-BMH
Exiom Solution S A
550.0 W Tie (0 W) 49.9 V 21.32% 93.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM72D30-550/MB?

Evaluate JA Solar JAM72D30-550/MB (550.0 W STC, 49.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72D30-550/MB reaches 55.76 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 407 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM72D30-550/MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM72D30-550/MB 8 kW Residential Fit

Needs 15 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare AMPS Solar AMPS-550P-144BB.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 516.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM72D30-550/MB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for JA Solar JAM72D30-550/MB?

Multiplying JA Solar JAM72D30-550/MB's 14.0 A short-circuit current by 1.56 equals 21.84 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can JA Solar JAM72D30-550/MB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.46 V cold Voc at 14 F and handles 14.0 A Isc; string inverters cap JA Solar JAM72D30-550/MB at 11 panels on 600 V.

Is JA Solar JAM72D30-550/MB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM72D30-550/MB rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.