JA Solar JAM72D30-550/MB is a 550.0 W STC (516.4 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.83% efficiency, 49.9 V Voc at 25 C, and 54.46 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 550.0 W
- PTC Wattage
- 516.4 W
- Voc @ 25C
- 49.9 V
- Efficiency
- 21.83%
How Does JA Solar JAM72D30-550/MB Compare Against Peer CEC Listings?
How JA Solar JA Solar JAM72D30-550/MB handles rooftop heat (516.4 W PTC), 8 kW sizing, and cold winter string voltage.
JA Solar builds the JA Solar JAM72D30-550/MB (Mono-c-Si) as a large-format commercial and ground-mount module delivering 218.3 W/m2 (1.92 percentage points above 19.91% CEC median). Compared against AMPS Solar AMPS-550P-144BB (550.0 W), this model holds strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677). Higher 49.9 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 21.84 A overcurrent floor served by a 25 A breaker.
Where Does JA Solar JAM72D30-550/MB Fall Across Listed CEC Models?
Where JA Solar JAM72D30-550/MB (550.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define JA Solar JAM72D30-550/MB?
Percentile placement of JA Solar JAM72D30-550/MB across power density (218.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for JA Solar JAM72D30-550/MB?
Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAM72D30-550/MB specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Top 13.8% STC Output
550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.83% Aperture Efficiency
Power density 218.3 W/m2 (1.92 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.46 V at -10 C (599.1 V string) and 55.76 V at -20 C (10 max).
15 Panels = 8,250 W STC
Occupies 37.8 m2 (407 sq ft) producing 7,746 W PTC; NEC 690.8 OCPD floor is 21.84 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.9 * (1 + (-0.261/100) * (-10 - 25)) = 54.46 V | OCPD = 1.56 * 14.0 = 21.84 A
Inputs from CEC Modules.csv for JA Solar JAM72D30-550/MB: Voc=49.9 V, beta_Voc=-0.261%/C, Isc=14.0 A, STC=550.0 W, Area=2.52 m2.
Result: 11 panels max on 600 V (599.1 V); 15 panels for 8 kW (407 sq ft).
What Are the Published CEC Specifications for JA Solar JAM72D30-550/MB?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAM72D30-550/MB.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 550.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 516.4 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.0 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.96 V / 13.11 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.261 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.83% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many JA Solar JAM72D30-550/MB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAM72D30-550/MB (550.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.05 kW | 298 sq ft | $1,514 | $2,561 |
| 8 kW Class | 15 | 8.25 kW | 407 sq ft | $2,065 | $3,492 |
| 10 kW Class | 19 | 10.45 kW | 515 sq ft | $2,616 | $4,423 |
How Many JA Solar JAM72D30-550/MB Modules Fit in a Cold-Weather String?
Maximum series module counts for JA Solar JAM72D30-550/MB from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.76 V | 10 panels | 557.6 V | 17 panels |
| -10 C (14 F) | 54.46 V | 11 panels | 599.1 V | 18 panels |
| 0 C (32 F) | 53.16 V | 11 panels | 584.8 V | 18 panels |
| 25 C (77 F STC) | 49.9 V | 12 panels | 598.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72D30-550/MB?
Alternative CEC solar modules from competing brands near JA Solar JAM72D30-550/MB (550.0 W), including AMPS Solar AMPS-550P-144BB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AMPS Solar AMPS-550P-144BB AMPS Solar |
550.0 W | Tie (0 W) | 49.9 V | 28.95% | 94.1% |
| Apollo Renewables Inc Apollo-M772BH-550TW Apollo Renewables Inc |
550.0 W | Tie (0 W) | 49.9 V | 21.48% | 93.6% |
| Exiom Solution S A EX550-144BMH-DG Exiom Solution S A |
550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.4% |
| Exiom Solution S A EX550-144M-BMH Exiom Solution S A |
550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.7% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM72D30-550/MB?
Evaluate JA Solar JAM72D30-550/MB (550.0 W STC, 49.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72D30-550/MB reaches 55.76 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 407 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM72D30-550/MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM72D30-550/MB 8 kW Residential Fit
Needs 15 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare AMPS Solar AMPS-550P-144BB.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 516.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM72D30-550/MB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for JA Solar JAM72D30-550/MB?
Multiplying JA Solar JAM72D30-550/MB's 14.0 A short-circuit current by 1.56 equals 21.84 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can JA Solar JAM72D30-550/MB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.46 V cold Voc at 14 F and handles 14.0 A Isc; string inverters cap JA Solar JAM72D30-550/MB at 11 panels on 600 V.
Is JA Solar JAM72D30-550/MB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM72D30-550/MB rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)